Data / Medical devices / United States / Integra Pain Management
Integra Pain Management: FDA-registered device maker in West Valley City, UT, United States, 11 510(k) clearances
Integra Pain Management is registered with the FDA (registration 1722447) in West Valley City, UT, United States. It lists 18 device types. The FDA files 11 510(k) clearances under its listings, the newest dated December 7, 2018. 14 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1722447
- FEI number
- 1000138491
- Address
- 3498 West 2400 South #1050, West Valley City, UT, United States, 84119
- Owner or operator
- Integra LifeSciences Corporation (9004007)
- Roles
- Contract manufacturer, Manufacturer, Repackager or relabeler
- First device listed
- April 24, 1981
- Registered through
- 2026
- Brand names listed
- CRW, CRW Biopsy Plus, CRW Precision Arc Steriotactic System, CRW-1 System, CUSA Clarity Ultrasonic Surgical Aspirator System; C7023; C7123; C7623; C7601; C7601EA, CUSA Clarity Ultrasonic Surgical Aspirator System; C7602; C7602EA, CUSA Excel+ Ultrasonic Surgical Aspirator System; C2623; C5623; CUSAEXCEL2; C2600; C5601; C5602, Codman Leroy Raney Scalp Bulk and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| December 7, 2018 | K182809 | CUSA Clarity Ultrasonic Surgical Aspirator System | LFL | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| December 6, 2016 | K160811 | CRW STEREOTACTIC SYSTEM | HAW | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| October 14, 2016 | K161882 | CUSA Clarity Ultrasonic Surgical Aspirator System | LFL | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| November 6, 2014 | K141674 | CUSA EXCEL+ ULTRASONIC SURGICAL ASPIRATOR SYSTEM | LFL | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| September 7, 2007 | K072208 | MAYFIELD DISPOSABLE AND REUSABLE TITANIUM SKULL PINS | HBL | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| June 13, 2007 | K071458 | MAYFIELD RADIOLUCENT DISPOSABLE SKULL PINS | HBL | Substantially Equivalent | Integra LifeSciences Corporation | accessdata.fda.gov |
| September 15, 2003 | K032054 | RADIONICS NASHOLD BIOPSY NEEDLE - SINGLE USE | HAW | Substantially Equivalent | Radionics, A Division of Tyco Healthcare Group LP | accessdata.fda.gov |
| June 5, 1996 | K961113 | CNS INTERCHANGEABLE BIT CRANIAL DRILL | HBG | Substantially Equivalent | Clinical Neuro Systems, LLC | accessdata.fda.gov |
| December 6, 1995 | K941558 | MAYFIELD CHILD DISPOSABLE SKULL PIN | HBL | Substantially Equivalent | Ohio Medical Instrument Co., Inc. | accessdata.fda.gov |
| September 28, 1993 | K932860 | MAYFIELD ADULT DISPOSABLE SKULL PIN | HBL | Substantially Equivalent | Ohio Medical Instrument Co., Inc. | accessdata.fda.gov |
| February 12, 1993 | K923789 | MAYFIELD ADULT DISPOSABLE SKULL PIN | HBL | Substantially Equivalent | Ohio Medical Instrument Co., Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 24, 2016 | 75029 | Class II | Terminated | PHS Spinal Tray 24G Gertie Marx, Catalogue No. 899379. Intended to provide licensed medical professionals with a kit containing drugs and other medical devices that are used to support the administration of general, loca | Integra LifeSciences has recently identified that one lot of Spinal Tray 24 G Gertie Marx Catalogue # 899379 was shipped containing the 24 G Gertie Marx needle without an introducer. | accessdata.fda.gov |
| August 24, 2016 | 75028 | Class II | Terminated | Integra Cranial Access Kits, Catalogue Nos. INSHITH; INSHITHRZN; INSHITHND | Integra LifeSciences has been notified of a medical device recall by Adaptive Surgical, LLC involving their Riverlon" Nylon 3-0 Sutures that are packaged in Integras Cranial Access Kits. It was found that product seals may become open during extreme distribution conditions and render the device unsterile. | accessdata.fda.gov |
| August 4, 2016 | 74867 | Class II | Terminated | INTEGRA Spinal Tray, Catalogue No: 3404875, Contents: 10 Each per Case, Sterile. | Integra LifeSciences is recalling Spinal Trays, Cat No. 3404875, because of the affected recalled Hospira 5% Lidocaine HCL that is a component of some lots of the Spinal Trays. | accessdata.fda.gov |
| September 22, 2015 | 72274 | Class II | Terminated | Integra Bone Marrow Biopsy Trays Catalogue No. 3404253 Various medical devices and components used to perform bone marrow biopsies are placed in a plastic tray which is sealed in an EtO sterilizable pouch. Vials of 1 % L | Integra received an Urgent Drug Recall Notice from Hospira Inc. for their 1% Lidocaine HCL Injection, USP, 10 mg/mL, Lot 44-359-DK. Hospira Inc. is recalling vials of Lot 44-359-DK, 1% Lidocaine HCL Injection, USP, 10 mg/mLm distributed by Hospira from February 2015 to March 2015 due to a confirmed complaint of visible, partially embedded particulate within | accessdata.fda.gov |
| May 1, 2015 | 71147 | Class II | Terminated | Integra Long Epidural Steroid Injection Needle (Tuohy Needle), 20 gauge x 5 inch. Plastic Hub, Metal Stylet, calibrations (10BX). Integra Long Epidural Steroid Injection Needle (Catalogue #PITRW2050). Peel Pouch. The Int | Integra LifeSciences Corp. d.b.a. Integra Pain Management Announces Voluntary Recall of Tuohy Needles (20 Gauge, 5 inch) due to incorrect packaging (labeled as 18 Gauge, 3. 5 inch). | accessdata.fda.gov |
| March 30, 2015 | 70873 | Class II | Terminated | Integra Long Epidural Steroid Injection Needle (Tuohy Needle), 18 Gauge x 5 inch Removable Wing, Metal Stylet, Calibrations (10BX), Catalogue No. PITRW1850. Used to administer steroid medication in the epidural space. | A single lot of 18 Gauge, 3.5 inch Tuohy Needles were incorrectly packaged and labeled as 18 Gauge, 5 inch needles. | accessdata.fda.gov |
| November 26, 2013 | 66949 | Class II | Terminated | Integra Cranial Access Kit, Model Number HITHSP10, Rx Only. Integra Cranial Access Kits (CRAK) allows for burr hole access to the subarachnoid space or the lateral ventricles of the brain. The kit is intended to be used | Integra LifeSciences is voluntarily recalling any unexpired lots of HITHSP10 Cranial Access Kits due to identified labeling discrepancies. kit contains DuraPrep and Monocryl sutures whose labeling does not align with the intended use and labeling of the Cranial Access Kit. | accessdata.fda.gov |
| October 28, 2013 | 66885 | Class II | Terminated | Integra Disposable, Convenience Kit Single Shot Epidural Tray Reorder Number 340269 Rx Only Product Usage: The Integra kits which contain a BD LOR syringe are intended to provide licensed medical professionals with a kit | Integra LifeSciences Corporation is recalling certain lots of Integra Kits for Epidural Anesthesia Administration as a result of a Product Advisory Notice from BD Medical for the LOR syringes indicating the plunger of the syringe may stall or stick when travelling within the syringe. | accessdata.fda.gov |
| September 4, 2013 | 66186 | Class II | Terminated | Cranial Access (CRAK) Kits, Product / Catalogue No.s: INSHITH, INSHITHND, INSHITHRZN The kits allow for access to the subarachnoid space or the lateral ventricles of the brain. The kits are intended to be used with an ex | Integra is recalling certain lots of Cranial Access Kit due to a possibility that the seal integrity of the sterile package may become compromised during shipping. | accessdata.fda.gov |
| June 7, 2012 | 61525 | Class III | Terminated | Single Shot Epidural Trays, Sterile, Integra Pain Management, West Valley City, Utah 84119, each kit contains sterile instruments, drugs and other medical materials that will support the administration of spinal anesthes | Integra LifeSciences is recalling one lot of Single Shot Epidural Trays as the product was inadvertently shipped missing injectable components. | accessdata.fda.gov |
| December 21, 2011 | 60798 | Not yet classified | Terminated | 1104HC Integra NeuroSciences Ventricular Bold Monitoring Kit W/ Cranial Access, Drain including (1) Cranial Kit W/Cam. Chuck, (1) Ventricular Bolt ICP Monitoring Kit, (1) CSF Drainage System. Contains Sterile and Non-Ste | Current package insert was revised to include additional warning information related to the potential hazards of an unapproved off-label use of Xylocaine. | accessdata.fda.gov |
| July 13, 2009 | 52683 | Not yet classified | Terminated | Nerve Block Tray, Disposable, Convenience Kit, Reorder Number DYNJTS0382B, Integra LifeSciences Corporation, Salt Lake City, Utah 84104. Kits contain syringes, drugs, sponges, drapes and other products supplied by outsid | Lack of packaging seal integrity on various pain management kits may compromise sterility of contents. | accessdata.fda.gov |
| July 7, 2008 | 48971 | Not yet classified | Terminated | Radiation Reduction Gloves, sterile, Latex-free, Catalog No. SSR1-7.0, SSR1-7.5, SSR1-8.0, Integra Pain Management, 3395 West 1820 South, Salt Lake City, Utah 84104. | Radiation reduction gloves were labeled as "Latex-free", but contain natural rubber latex. | accessdata.fda.gov |
| March 18, 2008 | 47373 | Not yet classified | Terminated | Integra LifeSciences Corporation Disposable Convenience Kit, PICC Insertion Tray, CUS791 | Hep-Lock Flush vials included in Integra's PICC Insertion Trays contain a heparin component that has been recalled by Baxter for contaminated heparin. | accessdata.fda.gov |
Compare with other makers
- All makers of Holder, Head, Neurosurgical (Skull Clamp)
- All makers of Knife, Ent
- All makers of Sound, Uterine
- All makers of Table And Attachments, Operating-Room
- All makers of Percussor
- All makers of Retractor, All Types
Updated December 7, 2018. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.