Data / Medical devices / United States / IMRIS Imaging, Inc.
IMRIS Imaging, Inc.: FDA-registered device maker in Chaska, MN, United States, 13 510(k) clearances
IMRIS Imaging, Inc. is registered with the FDA (registration 3010326005) in Chaska, MN, United States. It lists 12 device types. The FDA files 13 510(k) clearances under its listings, the newest dated August 6, 2025. 15 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3010326005
- Address
- 1230 Chaska Creek Way Suite 100, Chaska, MN, United States, 55318
- Owner or operator
- IMRIS Imaging, Inc. (10050332)
- Roles
- Complaint file establishment, Manufacturer, Specification developer
- First device listed
- November 4, 2015
- Registered through
- 2026
- Brand names listed
- Adult Horseshoe Pad Set, Case of 5, Application Platform 4-F NA - 2 Room Fixed, HC150 and HC300 Coils, HFD100, HFD100 Rocker Arm Accessory, Horseshoe Headrest, Horseshoe Headrest HFD100 Assembly, Horseshoe Headrest HFD200 Assembly and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Coil, Magnetic Resonance, Specialty | MOS | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Device, Digital Image Storage, Radiological | LMB | 1 | Manufacturer | accessdata.fda.gov |
| Headrest, Neurosurgical | HBM | 1 | Manufacturer | accessdata.fda.gov |
| Holder, Head, Neurosurgical (Skull Clamp) | HBL | 2 | Manufacturer | accessdata.fda.gov |
| System, Digital Image Communications, Radiological | LMD | 1 | Manufacturer | accessdata.fda.gov |
| System, Nuclear Magnetic Resonance Imaging | LNH | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| System, Nuclear Magnetic Resonance Spectroscopic | LNI | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| System, X-Ray, Angiographic | IZI | 2 | Manufacturer | accessdata.fda.gov |
| Table, Operating-Room, Ac-Powered | FQO | 1 | Manufacturer | accessdata.fda.gov |
| Table, Operating-Room, Electrical | GDC | 1 | Manufacturer | accessdata.fda.gov |
| Table, Radiologic | KXJ | 2 | Manufacturer | accessdata.fda.gov |
| Tape, Measuring, Rulers And Calipers | FTY | 1 | Manufacturer, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| August 6, 2025 | K252239 | InVision 3T Recharge Operating Suite | LNH | Substantially Equivalent | Imris Imaging, Inc. | accessdata.fda.gov |
| February 15, 2024 | K240157 | InVision 1.5 Surgical Theatre | LNH | Substantially Equivalent | Deerfield Imaging, Inc. | accessdata.fda.gov |
| August 23, 2021 | K212367 | IMRIS iMRI 3T V | LNH | Substantially Equivalent | Deerfield Imaging, Inc. | accessdata.fda.gov |
| September 4, 2014 | K141950 | HFD100 ROCKER ARM ACCESSORY | HBL | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| February 10, 2014 | K133692 | IMRI 1.5T AND IMRI 3T S | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| March 23, 2012 | K113748 | IMRIS MR/X-RAY HEAD FIXATION DEVICE (HFD) | HBL | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| March 11, 2011 | K103493 | HEAD FIATION DEVICE (HFD 100) | HBL | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| February 2, 2011 | K103506 | 1.5T HEAD COIL (HC150), 3T HEAD COIL (HC300) | MOS | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| October 5, 2010 | K101813 | IMRX SYSTEM V1 AND IMRISNV/IMRISCARDIO | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| September 2, 2009 | K091166 | IMRX | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| December 16, 2008 | K083137 | NEURO III-SV | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| May 22, 2007 | K071099 | NEURO II-SE, MODELS: OR-DR-OR, OR-MB | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
| August 11, 2006 | K061916 | NEURO II-SE, MODELS OR-MB-DR AND OR-DR | LNH | Substantially Equivalent | Imris, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 6, 2026 | 99596 | Class II | Ongoing | ORT200, operating room table, including the ORT200 Covered Table Assembly, Reconditioned, Part Number 113821-600 and the ORT200 50/60Hz Covered Table Assy V2 Part Number 114148-000 | The linear actuator and rotational lock mechanism components may experience a mechanical failure that prevents the system from transitioning between locked and unlocked state. This may pose a risk of injury to the patient if unintended rotational movement occurs during a procedure. | accessdata.fda.gov |
| December 8, 2025 | 98132 | Class II | Ongoing | Brand Name: HFD100 Product Name: Head Fixation Device HFD100 Model/Catalog Number: 119695-000, 119629-000, 119630-000, 113803-000, 113803-600, 113802-000, 113802-600 Software Version: Not Applicable Product Description: | Torque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision, procedural delays, requirement for alternate head fixation methods, and risk of patient injury. | accessdata.fda.gov |
| September 30, 2025 | 97750 | Class I | Ongoing | IMRIS Operating Suite, Neuro III-SV iMRI System, iMRX System, containing Siemens 3 Tesla MRI Magnet, Verio | There is a potential safety issue associated with the magnet venting paths of the Siemens 3 Tesla MRI system within your IMRIS Operating Suite. Siemens notified IMRIS that an ice blockage may exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed vent paths, leading to a pressure build-up wit | accessdata.fda.gov |
| February 17, 2022 | 89713 | Class II | Terminated | Trumpf Mount Clamp Assembly (table adapter component), part #118704-000, a component of the IMRIS HFD100 head fixation device, models #119629-000 and #119630-000, which are used with ORT400 operating room tables. | Reports have been received that after normal or routine lateral forces are applied to the head fixation device, the split block clamp may deflect (rotationally around the axis) and not return to within acceptable distance from its prior position after the force is removed. In order to reduce deflection at the table mount location, users have tightened the ha | accessdata.fda.gov |
| August 25, 2021 | 88661 | Class II | Terminated | Operating room table - Product Usage: intended for use during diagnostic examinations, radiologic procedures or surgical procedures to support and position a patient. | ORT200/300 rotational lock may fail to function such that it cannot change states between locked and unlocked, due to a mechanical hardware issue. | accessdata.fda.gov |
| November 26, 2019 | 84400 | Class II | Terminated | iMRX MRI and Angiography System, part number 10094137 and 10094141, a surgical/interventional suite with integrated MRI and X-ray angiography. The IMRIS iMRX system is the integration of a Siemens Artis zee family (bipla | There is a potential hardware error for the iMRX System with a generator A100. A tolerance issue in the power supply of the generator control above a specific value may cause generator A100 failure. As a result, the X-ray tube will not be supplied with the required voltage and X-ray will not be possible | accessdata.fda.gov |
| June 26, 2019 | 83278 | Class II | Terminated | IMRIS MR/X-ray head fixation device, Model HFD200 | Breaking of the HFD200 Drive Knob force indicator due to over-torqueing of the drive knob beyond the maximum allowable pinning force specification may result in the clinical staff unknowingly pinning the patient's skull with insufficient force; the clinical staff unknowingly pinning the patient's skull with excessive force; or the clinical staff identifying | accessdata.fda.gov |
| November 6, 2018 | 81574 | Class II | Terminated | IMRIS T2X table, Part Numbers: (a)108000-000, (b)108000-600, (c)109682-000, (d) 109682-600, (e) 110470-600 - Product Usage: The ORT200 and ORT300 are intended for use during diagnostic examinations, radiologic procedures | Table may drift in the roll position while in use | accessdata.fda.gov |
| April 4, 2018 | 79816 | Class II | Terminated | IMRIS IMRI 1.5T AND 3T S System Product Usage: The IMRIS intraoperative MRI systems are traditional MRI systems that have been suspended on an overhead rail system. and is designated to operative inside an RF shielded ro | The DC power to the IFOSS collision detector control panel at your facility is being adversely affected by the magnetic field. Our investigation shows the magnetic field is causing the IFOSS control panel to malfunction. | accessdata.fda.gov |
| February 23, 2018 | 79488 | Class II | Terminated | IMRIS ORT100 Table, Part Numbers: (a) 110470-000 (b) 110470-600 | The Operating Room Table may drift while in use, which could potentially result in unintended movement of the table. | accessdata.fda.gov |
| February 23, 2018 | 79366 | Class II | Terminated | IMRIS ORT200 Removable Operating Room Table, 50-60 Hz Version is intended for use during diagnostic examinations or surgical procedures to support and position a patient. | The rotational locking mechanisms on the ORT 200/300 tables fail to operate such that it cannot change states between locked and unlocked. | accessdata.fda.gov |
| February 20, 2018 | 79360 | Class II | Terminated | IMRIS ORT100 Table, Part Number 110470-000 | The rotational locking mechanisms on the ORT 100/ T2X tables can become disengaged or unlocked while in use which could potentially result in unintended movement of the table. | accessdata.fda.gov |
| August 14, 2017 | 77996 | Class II | Terminated | IMRIS DEERFIELD IMAGING, REF 113803, Starburst adaptor thumb screw | incorrect thread on thumbscrews | accessdata.fda.gov |
| February 10, 2016 | 73421 | Class II | Terminated | Intra operative MRI Systems: Neuro II-SE, Neuro III-SV, iMRI 1.5T A, and iMRI 3T S. Indicated for use as a magnetic resonance diagnostic device (MRDD). | Emergency helium venting lines (i.e. quench lines) may not have been properly installed. | accessdata.fda.gov |
| October 1, 2014 | 69265 | Class II | Terminated | IMRIS Operating Room table (ORT200 and ORT300). Intended for use during diagnostic examinations or surgical procedures to support and position a patient. | One of the three pins that is used to hold the ORT200 table alignment block in place on the floor of the MR Suite went missing during testing at a health care facility. | accessdata.fda.gov |
Compare with other makers
- All makers of System, Nuclear Magnetic Resonance Spectroscopic
- All makers of Coil, Magnetic Resonance, Specialty
- All makers of System, Nuclear Magnetic Resonance Imaging
- All makers of Holder, Head, Neurosurgical (Skull Clamp)
- All makers of System, X-Ray, Angiographic
- All makers of System, Digital Image Communications, Radiological
Updated August 26, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.