Data / Medical devices / Switzerland / Icotec AG
Icotec AG: FDA-registered device maker in Altstaetten Sankt Gallen, Switzerland, 15 510(k) clearances
Icotec AG is registered with the FDA (registration 3006493760) in Altstaetten Sankt Gallen, Switzerland. It lists 10 device types. The FDA files 15 510(k) clearances under its listings, the newest dated November 12, 2025. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3006493760
- Address
- Industriestrasse 12, Altstaetten Sankt Gallen, Switzerland, 9450
- Owner or operator
- icotec ag (10042564)
- Roles
- Complaint file establishment, Manufacturer
- First device listed
- June 15, 2018
- Registered through
- 2026
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| November 12, 2025 | K252327 | CMORE® CT System; CMORE® CT System Navigated Instruments | NKG | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| February 27, 2025 | K242900 | VADER® Pedicle System and VADER®one Pedicle System | NKB | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| May 17, 2024 | K233215 | icotec Anterior Cervical Plate System | KWQ | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| April 5, 2024 | K232792 | icotec Interbody Cage System (icotec Cervical Cage, icotec PLIF Lumbar Cage, icotec ETurn TLIF Lumbar Cage) | MAX | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| April 4, 2024 | K232790 | KONG®-TL VBR System and KONG® C VBR System | MQP | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| February 26, 2024 | K232628 | VADER® Pedicle System | NKB | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| June 27, 2023 | K230861 | VADER® Pedicle System Navigated Instruments | OLO | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| January 9, 2023 | K222789 | VADER® Pedicle System, G21 Cement | PML | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| October 15, 2020 | K201587 | icotec Anterior Cervical Plate System | KWQ | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| October 13, 2020 | K200596 | G21 Cement, VADER® Pedicle System | PML | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| May 29, 2020 | K200235 | KONG-TL VBR System, KONG-C VBR System | MQP | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| May 22, 2020 | K193423 | VADER®one Pedicle System MIS and LightMore® Pedicle System 6.0 | NKB | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| March 20, 2020 | K192897 | icotec Cervical Cage | ODP | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| June 20, 2019 | K190545 | VADER® one Pedicle System MIS and LightMore® Pedicle System 6.0 | NKB | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
| May 17, 2018 | K172480 | icotec Interbody Cage System | ODP | Substantially Equivalent | Icotec AG | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| November 28, 2023 | 93577 | Class II | Ongoing | VADER pedicle system, torque wrench, Catalog Number 42-702 | icotec has received notification of one revision that had to be carried out because nut screws had become loose. During the investigation of the device involved, it was detected that the torque limiting function of the wrench used to tighten the nut screws during implantation was not functioning correctly. Due to the malfunction, the nut screws may not have | accessdata.fda.gov |
| November 3, 2022 | 91174 | Class II | Terminated | VADER Pedicle System Torque Wrench, Hudson Coupling, 12 Nm, REF 42-702 | During internal testing (at manufacturer site) of two torque wrench devices, it was detected that the torque limiting function was out of specification. The specified torque limiting value is 12 Nm. The measuring results for both instruments were 4 Nm. | accessdata.fda.gov |
Compare with other makers
- All makers of Bone Cement, Posterior Screw Augmentation
- All makers of Thoracolumbosacral Pedicle Screw System
- All makers of Appliance, Fixation, Spinal Intervertebral Body
- All makers of Intervertebral Fusion Device With Bone Graft, Cervical
- All makers of Intervertebral Fusion Device With Bone Graft, Lumbar
- All makers of Orthopedic Manual Surgical Instrument
Updated November 12, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.