Data / Medical devices / Germany / Human Med AG
Human Med AG: FDA-registered device maker in SCHWERIN Mecklenburg-Western Pomerania, Germany, 2 510(k) clearances
Human Med AG is registered with the FDA (registration 3003587189) in SCHWERIN Mecklenburg-Western Pomerania, Germany. It lists 7 device types. The FDA files 2 510(k) clearances under its listings, the newest dated August 13, 2008. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3003587189
- Address
- Wilhelm-Hennemann-Str.9, SCHWERIN Mecklenburg-Western Pomerania, Germany, 19061
- Owner or operator
- Human Med AG (9043320)
- Roles
- Manufacturer
- First device listed
- September 12, 2008
- Registered through
- 2026
- Brand names listed
- Biofill Infiltration cannula (Model #: 580107), Biofill Infiltration cannula, 2.5mm D, 15cm L, single-use (Model #: 1580107), Biofill applicator, for Biofill cannulas (for body-jet evo and body-jet eco only) (Model #: 580001), Biofill cannula (Model #: 580086), Biofill cannula (Model #: 580089), Biofill cannula, 2 long suction holes, 3.5mm D, 15cm L, single-use (Model #: 1580086), Biofill cannula, 3.8mm D, 15cm L, 4 suction holes (Model #: 580125), Biofill cannula, 3.8mm D, 15cm L, 4 suction holes, RAPID (Model #: 581125) and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Cannula, Surgical, General & Plastic Surgery | GEA | 1 | Manufacturer | accessdata.fda.gov |
| Connector, Catheter | GCD | 1 | Manufacturer | accessdata.fda.gov |
| Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use | LXG | 1 | Manufacturer | accessdata.fda.gov |
| Lavage, Jet | FQH | 2 | Manufacturer | accessdata.fda.gov |
| Lipoaspirate Washing System For Aesthetic Body Contouring | QKL | 2 | Manufacturer | accessdata.fda.gov |
| System, Suction, Lipoplasty For Removal | QPB | 2 | Manufacturer | accessdata.fda.gov |
| Tube, Aspirating, Flexible, Connecting | BYY | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| August 13, 2008 | K082025 | BODY-JET | QPB | Substantially Equivalent | Human Med AG | accessdata.fda.gov |
| October 10, 2001 | K012464 | HELIX HYDRO-JET | FQH | Substantially Equivalent | Andreas Pein Medizintechnik GmbH | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 18, 2024 | 96137 | Class II | Ongoing | human med Biofill Infiltration Cannula, diameter 2.5mm, 15cm, REF 2024-012, REF 1580107, sterile, single use. | The cannula tubes do not comply with the specification. The water jet emerging from the nozzle of the nonconforming cannulas may emerge as a spot jet rather than a fan-shaped spray jet. | accessdata.fda.gov |
Compare with other makers
- All makers of Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical Use
- All makers of System, Suction, Lipoplasty For Removal
- All makers of Lavage, Jet
- All makers of Lipoaspirate Washing System For Aesthetic Body Contouring
- All makers of Tube, Aspirating, Flexible, Connecting
- All makers of Cannula, Surgical, General & Plastic Surgery
Updated February 28, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.