Hangzhou Bever Medical Devices Co., Ltd. is registered with the FDA (registration 3008729910) in Hangzhou Zhejiang, China. It lists 3 device types. The FDA files 2 510(k) clearances under its listings, the newest dated November 27, 2019. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3008729910
Address
Building 2, No. 1-1, Houmuqiao Yongle Village, Cangqian Street, Yuhang District, Hangzhou Zhejiang, China, 311121
Owner or operator
Hangzhou Bever Medical Devices Co., Ltd. (10034111)
Roles
Specification developer
First device listed
November 5, 2010
Registered through
2026
Brand names listed
BD Intermittent Catheter, BD Ready-to-Use Hydrophilic Catheter, Intermittent Catheter, Nasopharyngeal Airway, Ready-to-Use Hydrophilic Catheter, Robertazzi Nasopharyngeal Airway

Devices it lists

DeviceProduct codeClassRoleSource
Airway, NasopharyngealBTQ1Specification developeraccessdata.fda.gov
Catheter, StraightEZD2Specification developeraccessdata.fda.gov
Catheter, UrethralGBM2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
November 27, 2019K192468Male, Nelaton-tip Ready-to-Use Hydrophilic Catheter; Femal, Nelaton-tip Ready-to-Use Hydrophilic Catheter; Pediatric, Nelaton-tip Ready-to-Use Hydrophilic Catheter Intermittent Catheter; Male, Tapered-Tip Tiemann Ready-to-Use Hydrophilic Catheter; Male, Olive-Tip Tiemann Ready-to-Use Hydrophilic CatheterGBMSubstantially EquivalentHangzhou Bever Medical Devices Co., Ltd.accessdata.fda.gov
February 13, 2012K111405BEVER UNOCATED / COATED, PAEDIATRIC / MALE / FEMALE NELATON-TIP / TIEMANN-TIP INTERMITTENT CATHETER,GBMSubstantially EquivalentHangzhou Bever Medical Devices Co., Ltd.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
November 29, 202598147Class IIOngoingBD Ready-to-Use Hydrophilic Catheter 14 Fr (4.7 mm) Straight Tip, Coated, Female REF: RTU14FLabeling error, Incorrect expiration dateaccessdata.fda.gov

Compare with other makers

Updated January 12, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.