Hamilton Medical AG: FDA-registered device maker in Domat / Ems Graubunden, Switzerland, 10 510(k) clearances

Hamilton Medical AG is registered with the FDA (registration 3014766741) in Domat / Ems Graubunden, Switzerland. It lists 9 device types. The FDA files 10 510(k) clearances under its listings, the newest dated February 5, 2021. 5 recall events name it as the recalling firm (3 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3014766741
Address
Parc lndustrial Vial 10, Domat / Ems Graubunden, Switzerland, 7013
Owner or operator
Hamilton Medical AG (10059168)
Roles
Exporter to the US, Manufacturer
First device listed
June 18, 2019
Registered through
2026
Brand names listed
Breathing circuit set, coaxial, single use, adult/pediatric PN 260094, PN 260127, PN 260128, PN 260184, PN 260206, Breathing circuit set, coaxial, single use, adult/pediatric PN 260167, PN 260168, PN 260145, PN 260144, PN 260087, Breathing circuit set, coaxial, single use, adult/pediatric PN 260207, PN 260239, PN 260240, PN 260257, Breathing circuit sets, dual limb, single use, neonatal PN 260180, PN 260182, PN 260169, PN 260170, Breathing circuit sets, dual limb, single use, neonatal/pediatric PN 260241, PN 260244, Expiratory valve set , reusable, PN 161175, PN 161188, PN 151972, PN 160245, Expiratory valve set , single use, PN 160176, PN 161186, PN 161189, PN 950158, Flow sensor, single use, adult/pediatric PN 282051, PN 281637, PN 950185 and more

Devices it lists

DeviceProduct codeClassRoleSource
Compressor, Air, PortableBTI2Exporter to the US, Manufactureraccessdata.fda.gov
Cuff, Tracheal Tube, InflatableBSK2Exporter to the US, Manufactureraccessdata.fda.gov
Heater, Breathing System W/Wo Controller (Not Humidifier Or NebulizerBZE2Exporter to the US, Manufactureraccessdata.fda.gov
Humidifier, Respiratory Gas, (Direct Patient Interface)BTT2Exporter to the US, Manufactureraccessdata.fda.gov
Mixer, Breathing Gases, Anesthesia InhalationBZR2Exporter to the US, Manufactureraccessdata.fda.gov
OximeterDQA2Exporter to the US, Manufactureraccessdata.fda.gov
Set, Tubing And Support, Ventilator (W Harness)BZO1Exporter to the US, Manufactureraccessdata.fda.gov
Tubing, Pressure And AccessoriesBYX1Exporter to the US, Manufactureraccessdata.fda.gov
Ventilator, Continuous, Facility UseCBK2Exporter to the US, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
February 5, 2021K201306HAMILTON-C3CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
December 11, 2020K201658Hamilton-C6CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
May 4, 2020K193228Hamilton-G5CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
August 2, 2019K181216HAMILTON-T1, HAMILTON-C1CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
September 20, 2017K163283HAMILTON-H900, HAMILTON-BC8010, HAMILTON-BC4010BTTSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
September 6, 2016K153046HAMILTON-MR1CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
May 3, 2016K152029HAMILTON-H900, HAMILTON-BC8022, HAMILTON-BC4022, HAMILTON-BC8010, HAMILTON-BC4010BTTSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
January 29, 2016K150893IntelliCuffBSKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
November 16, 2012K121225HAMILTON-C2CBKSubstantially EquivalentHamilton Medical AGaccessdata.fda.gov
March 14, 2005K041781VENTILAIR II MEDICAL AIR COMPRESSORBTISubstantially EquivalentHamilton Medical AGaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 29, 202699028Class IOngoingBreathing circuit set, coaxial: REF: 260127, 260128, 260167, 260168 used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 ventilators.Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will result in "exhalation obstructed " alarm, which may result in inadequate ventilation, oxygen desaturation. Advising: Prior to use, test lung action. If alarm occurs, expiratory valve set removal to oaccessdata.fda.gov
May 22, 202699035Class IIOngoingIntelliCuff, Portable automatic cuff pressure controller REF: 951001Due to reported complaints, the cuff device may alarm with a "Cuff System Leakage" error. As a result, the motor may pump continuously and fail to maintain the cuff pressure set by the user.accessdata.fda.gov
June 26, 202597222Class IOngoingBreathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 ventilators.Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory and expiratory flows, leading to partial or complete rebreathing of exhaled gases, which could lead to acute hypercapnia, respiratory acidosis, and if unrecognized organ dysfunction.accessdata.fda.gov
June 3, 202597079Class IOngoingHamilton C6 REF 160021 (ESM Board PN 10144626 UDI-DI code: 76300028PN160021ZW Hamilton C6 is a ventilator intended to provide positive pressure ventilatory support to adults and pediatrics and optionally infants and neonA mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (no patient involvement) or during the use of the device enter ambient state, resulting in an interruption of ventilation.accessdata.fda.gov
September 22, 202290916Class IIOngoingHamilton-C6Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the backlight switches on again.accessdata.fda.gov

Compare with other makers

Updated June 30, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.