Data / Medical devices / Switzerland / Hamilton Medical AG
Hamilton Medical AG: FDA-registered device maker in BONADUZ Graubunden, Switzerland, 6 510(k) clearances
Hamilton Medical AG is registered with the FDA (registration 3001421318) in BONADUZ Graubunden, Switzerland. It lists 7 device types. The FDA files 6 510(k) clearances under its listings, the newest dated February 5, 2021. 7 recall events name it as the recalling firm (3 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3001421318
- Address
- Via Crusch 8, BONADUZ Graubunden, Switzerland, 7402
- Owner or operator
- Hamilton Medical AG (10059168)
- Roles
- Specification developer
- First device listed
- June 18, 2019
- Registered through
- 2026
- Brand names listed
- Breathing circuit set, coaxial, single use, adult/pediatric PN 260094, PN 260127, PN 260128, PN 260184, PN 260206, Breathing circuit set, coaxial, single use, adult/pediatric PN 260167, PN 260168, PN 260145, PN 260144, PN 260087, Breathing circuit set, coaxial, single use, adult/pediatric PN 260207, PN 260239, PN 260240, PN 260257, Breathing circuit sets, dual limb, single use, neonatal PN 260180, PN 260182, PN 260169, PN 260170, Breathing circuit sets, dual limb, single use, neonatal/pediatric PN 260241, PN 260244, Expiratory valve set , reusable, PN 161175, PN 161188, PN 151972, PN 160245, Expiratory valve set , single use, PN 160176, PN 161186, PN 161189, PN 950158, Flow sensor, single use, adult/pediatric PN 282051, PN 281637, PN 950185 and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer | BZE | 2 | Specification developer | accessdata.fda.gov |
| Humidifier, Respiratory Gas, (Direct Patient Interface) | BTT | 2 | Specification developer | accessdata.fda.gov |
| Mixer, Breathing Gases, Anesthesia Inhalation | BZR | 2 | Specification developer | accessdata.fda.gov |
| Oximeter | DQA | 2 | Specification developer | accessdata.fda.gov |
| Set, Tubing And Support, Ventilator (W Harness) | BZO | 1 | Specification developer | accessdata.fda.gov |
| Tubing, Pressure And Accessories | BYX | 1 | Specification developer | accessdata.fda.gov |
| Ventilator, Continuous, Facility Use | CBK | 2 | Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| February 5, 2021 | K201306 | HAMILTON-C3 | CBK | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
| December 11, 2020 | K201658 | Hamilton-C6 | CBK | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
| August 2, 2019 | K181216 | HAMILTON-T1, HAMILTON-C1 | CBK | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
| September 20, 2017 | K163283 | HAMILTON-H900, HAMILTON-BC8010, HAMILTON-BC4010 | BTT | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
| September 6, 2016 | K153046 | HAMILTON-MR1 | CBK | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
| May 3, 2016 | K152029 | HAMILTON-H900, HAMILTON-BC8022, HAMILTON-BC4022, HAMILTON-BC8010, HAMILTON-BC4010 | BTT | Substantially Equivalent | Hamilton Medical AG | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| May 15, 2024 | 94671 | Class I | Ongoing | Ventilator HAMILTON-C6, PN: 160021 | Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilatio | accessdata.fda.gov |
| March 14, 2023 | 91925 | Class II | Ongoing | HAMILTON-C6, REF: 160021 | Software error causes, safety ventilation, in which ventilation continues in the "safety ventilation" mode with audible/visible alarm - patient inputs are not monitored, if the following coincide 1) A mode change to an adaptive mode (ASV, APVcmv, APVsimv, INTELLiVENT-ASV, (S)CMV+, SIMV+), and 2) The controller and/or humidifier is connected to the ventilator | accessdata.fda.gov |
| June 27, 2022 | 90576 | Class I | Ongoing | HAMILTON-C6 Intensive Care Ventilator, REF: 160021 | Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technical faults in a short time may force ventilators into Safety Ventilation (blower runs constantly) or Ambient Sate (inspiratory channel/expiratory valves opened; patient breaths room air unassisted) with | accessdata.fda.gov |
| January 5, 2021 | 90460 | Class III | Completed | HAMILTON-H900 Humidifier, Models: 950001, 950004 | When starting a humidifier, intended for respiratory gas conditioning during invasive and noninvasive mechanical ventilation, with an empty chamber, and water is not filled into the chamber, the low water level alarm will be delayed and medical staff are unaware that there is no water in the chamber. | accessdata.fda.gov |
| March 25, 2019 | 82328 | Class I | Terminated | HAMILTON-G5, with software versions less than or equal to 2.60 The HAMILTON-G5/S1 ventilators are designed for intensive care ventilation of adult and pediatric patients, and optionally infant and neonatal patients. The | New software version for affected ventilators reduces the probability of the ventilator entering an ambient state, in which the inspiratory channel and expiratory valves are opened, letting the patient breathe room air unassisted. When the ventilator enters the ambient state, alternative ventilation must be provided immediately. | accessdata.fda.gov |
| March 12, 2018 | 78599 | Class II | Ongoing | Hamilton-C2 Ventilator Unit Intended to provide ventilator support to adults and pediatrics and optionally infants and neonates in the hospital. | After two and a half years, the battery fuel gauge may indicate a higher battery charge than what is available. | accessdata.fda.gov |
| March 9, 2018 | 80467 | Class II | Terminated | Hamilton-C1 Ventilator Unit Product Usage: The HAMILTON-C1 ventilator is intended to provide positive pressure ventilation support to adults and pediatrics. The device is used in the in the intensive care ward, in the re | An out of specification component on the control board may cause the ventilator to open the inspiratory channel and the expiratory valve. The ventilator will shut down and an emergency buzzer providing an acoustic alarm and the blinking alarm LED on the device s front side. | accessdata.fda.gov |
Compare with other makers
- All makers of Ventilator, Continuous, Facility Use
- All makers of Set, Tubing And Support, Ventilator (W Harness)
- All makers of Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
- All makers of Humidifier, Respiratory Gas, (Direct Patient Interface)
- All makers of Tubing, Pressure And Accessories
- All makers of Oximeter
Updated June 18, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.