Data / Medical devices / Israel / Given Imaging Ltd.
Given Imaging Ltd.: FDA-registered device maker in Yoqneam Northern, Israel, 11 510(k) clearances
Given Imaging Ltd. is registered with the FDA (registration 9710107) in Yoqneam Northern, Israel. It lists 6 device types. The FDA files 11 510(k) clearances under its listings, the newest dated May 10, 2024. 2 recall events name it as the recalling firm (2 Class I). Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 9710107
- FEI number
- 3003348376
- Address
- 2 Hacarmel St. NEW INDUSTRIAL Park, POB 258, Yoqneam Northern, Israel, 2069204
- Owner or operator
- GIVEN IMAGING INC. (10091555)
- Roles
- Manufacturer
- First device listed
- October 15, 2024
- Registered through
- 2027
- Brand names listed
- Accessories, AccuView pH & pH-Z software, Activation Fixture, Bravo System, Bravo CF reflux recorder, Bravo Reflux Capsule with Delivery Device, DR3, Digitrapper pH Z and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Colon Capsule Imaging System | PGD | 2 | Manufacturer | accessdata.fda.gov |
| Electrode, Ph, Stomach | FFT | 1 | Manufacturer | accessdata.fda.gov |
| Gastrointestinal Motility System, Capsule | NYV | 2 | Manufacturer | accessdata.fda.gov |
| System, Gastrointestinal Motility (Electrical) | FFX | 2 | Manufacturer | accessdata.fda.gov |
| System, Imaging, Esophageal, Wireless, Capsule | NSI | 2 | Manufacturer | accessdata.fda.gov |
| System, Imaging, Gastrointestinal, Wireless, Capsule | NEZ | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 10, 2024 | K240276 | PillCam Genius SB System with PillCam Software v9.7 and PillCam Cloud Reader Software | NEZ | Substantially Equivalent | Given Imaging Ltd. (D.B.A. Medtronic) | accessdata.fda.gov |
| June 30, 2023 | K230991 | PillCam SB 3 capsule endoscopy system, PillCam Software 9.0E | NEZ | Substantially Equivalent | Given Imaging Ltd. (Medtronic) | accessdata.fda.gov |
| August 27, 2021 | K211684 | PillCam SB 3 capsule endoscopy system, PillCam Software 9.0E | NEZ | Substantially Equivalent | Given Imaging Ltd. (Medtronic) | accessdata.fda.gov |
| March 8, 2018 | K180171 | PillCam Patency System | NSI | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| September 1, 2017 | K170210 | PillCam SBC capsule endoscopy system, PilCam Desktop Software 9.0 | NEZ | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| April 28, 2016 | K151086 | ManoScan System | FFX | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| January 14, 2016 | K153466 | PillCam COLON 2 Capsule Endoscopy System | PGD | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| December 17, 2014 | K140284 | GIVEN PILLCAM UGI CAPSULE ENDOSCOPY SYSTEM | NEZ | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| August 12, 2013 | K123864 | GIVEN PILLCAM ENDOSCOPY SYSTEM WITH RAPID 8.0, GIVEN PILLCAM SB 3 CAPSULE ENDOSCOPY SYSTEM | NEZ | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| December 1, 2010 | K102543 | BRAVO PH MONITORING SYSTEM AND ACCESSORIES | FFT | Substantially Equivalent | Given Imaging , Ltd. | accessdata.fda.gov |
| October 30, 2009 | K092342 | SMARTPILL GI MONITORING SYSTEM, VERSION 2.0 | NYV | Substantially Equivalent | The Smartpill Corporation | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 6, 2026 | 99626 | Class I | Ongoing | Bravo CF capsule delivery device, 5-pack, Product Number FGS-0635, Bravo CF capsule delivery device, 1-pack, Product Number FGS-0636. Used to attach a pH monitoring capsule to the esophagus. | Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in the patient. | accessdata.fda.gov |
| June 3, 2025 | 97029 | Class I | Ongoing | Bravo CF capsule delivery device, designed to place and attach a pH monitoring capsule to the esophagus using endoscopic or manometric guidance, Product Number FGS-0635 (5 pack) and FGS-0636 (1 pack) | It has been determined that misapplied adhesive on the Bravo CF capsule delivery device may lead to its malfunction. Specifically, the misapplied adhesive may prevent the capsule from attaching to the patient's esophagus or detaching from the delivery device. | accessdata.fda.gov |
Compare with other makers
- All makers of System, Imaging, Gastrointestinal, Wireless, Capsule
- All makers of Electrode, Ph, Stomach
- All makers of Gastrointestinal Motility System, Capsule
- All makers of System, Gastrointestinal Motility (Electrical)
Updated September 11, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.