Skip to the page

Data / Medical devices / Israel / Given Imaging Ltd.

Given Imaging Ltd.: FDA-registered device maker in Yoqneam Northern, Israel, 11 510(k) clearances

Given Imaging Ltd. is registered with the FDA (registration 9710107) in Yoqneam Northern, Israel. It lists 6 device types. The FDA files 11 510(k) clearances under its listings, the newest dated May 10, 2024. 2 recall events name it as the recalling firm (2 Class I). Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
9710107
FEI number
3003348376
Address
2 Hacarmel St. NEW INDUSTRIAL Park, POB 258, Yoqneam Northern, Israel, 2069204
Owner or operator
GIVEN IMAGING INC. (10091555)
Roles
Manufacturer
First device listed
October 15, 2024
Registered through
2027
Brand names listed
Accessories, AccuView pH & pH-Z software, Activation Fixture, Bravo System, Bravo™ CF reflux recorder, Bravo™ Reflux Capsule with Delivery Device, DR3, Digitrapper pH Z and more

Devices it lists

DeviceProduct codeClassRoleSource
Colon Capsule Imaging SystemPGD2Manufactureraccessdata.fda.gov
Electrode, Ph, StomachFFT1Manufactureraccessdata.fda.gov
Gastrointestinal Motility System, CapsuleNYV2Manufactureraccessdata.fda.gov
System, Gastrointestinal Motility (Electrical)FFX2Manufactureraccessdata.fda.gov
System, Imaging, Esophageal, Wireless, CapsuleNSI2Manufactureraccessdata.fda.gov
System, Imaging, Gastrointestinal, Wireless, CapsuleNEZ2Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
May 10, 2024K240276PillCam™ Genius SB System with PillCam Software v9.7 and PillCam Cloud Reader SoftwareNEZSubstantially EquivalentGiven Imaging Ltd. (D.B.A. Medtronic)accessdata.fda.gov
June 30, 2023K230991PillCam SB 3 capsule endoscopy system, PillCam Software 9.0ENEZSubstantially EquivalentGiven Imaging Ltd. (Medtronic)accessdata.fda.gov
August 27, 2021K211684PillCam SB 3 capsule endoscopy system, PillCam Software 9.0ENEZSubstantially EquivalentGiven Imaging Ltd. (Medtronic)accessdata.fda.gov
March 8, 2018K180171PillCam Patency SystemNSISubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
September 1, 2017K170210PillCam SBC capsule endoscopy system, PilCam Desktop Software 9.0NEZSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
April 28, 2016K151086ManoScan SystemFFXSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
January 14, 2016K153466PillCam COLON 2 Capsule Endoscopy SystemPGDSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
December 17, 2014K140284GIVEN PILLCAM UGI CAPSULE ENDOSCOPY SYSTEMNEZSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
August 12, 2013K123864GIVEN PILLCAM ENDOSCOPY SYSTEM WITH RAPID 8.0, GIVEN PILLCAM SB 3 CAPSULE ENDOSCOPY SYSTEMNEZSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
December 1, 2010K102543BRAVO PH MONITORING SYSTEM AND ACCESSORIESFFTSubstantially EquivalentGiven Imaging , Ltd.accessdata.fda.gov
October 30, 2009K092342SMARTPILL GI MONITORING SYSTEM, VERSION 2.0NYVSubstantially EquivalentThe Smartpill Corporationaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
August 6, 202699626Class IOngoingBravo CF capsule delivery device, 5-pack, Product Number FGS-0635, Bravo CF capsule delivery device, 1-pack, Product Number FGS-0636. Used to attach a pH monitoring capsule to the esophagus.Capsule may fail to attach to the esophagus or detach from the delivery device. Risks include patient aspiration/inhalation, perforation of esophagus, obstruction of the airway, hemorrhage/blood loss/bleeding, laceration of the esophagus, a delay in diagnosis, and foreign bodies remaining in the patient.accessdata.fda.gov
June 3, 202597029Class IOngoingBravo CF capsule delivery device, designed to place and attach a pH monitoring capsule to the esophagus using endoscopic or manometric guidance, Product Number FGS-0635 (5 pack) and FGS-0636 (1 pack)It has been determined that misapplied adhesive on the Bravo CF capsule delivery device may lead to its malfunction. Specifically, the misapplied adhesive may prevent the capsule from attaching to the patient's esophagus or detaching from the delivery device.accessdata.fda.gov

Compare with other makers

Updated September 11, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.