Data / Medical devices / Japan / FUJIFILM Healthcare Manufacturing Corporation Minamiashigara Takematsu Office
FUJIFILM Healthcare Manufacturing Corporation Minamiashigara Takematsu Office: FDA-registered device maker in MINAMIASHIGARA-SHI Kanagawa, Japan, 3 510(k) clearances
FUJIFILM Healthcare Manufacturing Corporation Minamiashigara Takematsu Office is registered with the FDA (registration 2155) in MINAMIASHIGARA-SHI Kanagawa, Japan. It lists 8 device types. The FDA files 3 510(k) clearances under its listings, the newest dated May 22, 2007. Registered through 2026. FDA data exported November 3, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 2155
- Address
- 1250 Takematsu, MINAMIASHIGARA-SHI Kanagawa, Japan, 250-0111
- Owner or operator
- FUJIFILM CORPORATION (8031568)
- Roles
- Contract manufacturer, Manufacturer
- First device listed
- April 4, 2007
- Registered through
- 2026
- Brand names listed
- FCR CARBON (CR-IR357), FCR CARBON XL-2 (CR-IR359), FCR PRIMA Tm(CR-IR392), FCR Prima T(CR-IR392), FCR Prima T2 (CR-IR392), FCR Prima T2(CR-IR392), FCR XC-2 (CR-IR357), FCR XL-2 (CR-IR359) and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Accelerator, Linear, Medical | IYE | 2 | Manufacturer | accessdata.fda.gov |
| Calibrator, Secondary | JIT | 2 | Contract manufacturer | accessdata.fda.gov |
| Des-Gamma-Carboxy-Prothrombin (Dcp), Risk Assessment, Hepatocellular Carcinoma | OAU | 2 | Contract manufacturer | accessdata.fda.gov |
| Micro Total Analysis Instrument System | OUE | 2 | Contract manufacturer | accessdata.fda.gov |
| Screen, Intensifying, Radiographic | EAM | 1 | Manufacturer | accessdata.fda.gov |
| Single (Specified) Analyte Controls (Assayed And Unassayed) | JJX | 1 | Contract manufacturer | accessdata.fda.gov |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | MQB | 2 | Manufacturer | accessdata.fda.gov |
| Test, Alpha Fetoprotein L3 Subfraction (Afp-L3%), For Hepatocellular Carcinoma Risk Assessment | NSF | 2 | Contract manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 22, 2007 | K070920 | FUJI IP CASSETTE TYPE PC | IYE | Substantially Equivalent | Fujifilm Medical Systems U.S.A, Inc. | accessdata.fda.gov |
| August 25, 2004 | K042023 | FUJI COMPUTED RADIOGRAPHY (FCR) CLEARVIEW CS IMAGE READER | MQB | Substantially Equivalent | Fujifilm Medical System U.S.A., Inc. | accessdata.fda.gov |
| February 26, 1987 | K862414 | FUJI CR IMAGING PLATE | EAM | Substantially Equivalent | Parexel Intl. Corp. | accessdata.fda.gov |
Compare with other makers
- All makers of Accelerator, Linear, Medical
- All makers of Solid State X-Ray Imager (Flat Panel/Digital Imager)
- All makers of Micro Total Analysis Instrument System
- All makers of Calibrator, Secondary
- All makers of Des-Gamma-Carboxy-Prothrombin (Dcp), Risk Assessment, Hepatocellular Carcinoma
- All makers of Test, Alpha Fetoprotein L3 Subfraction (Afp-L3%), For Hepatocellular Carcinoma Risk Assessment
Updated May 22, 2007. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.