Skip to the page

Data / Medical devices / United States / FLOWER ORTHOPEDICS CORPORATION DBA Conventus Flower

FLOWER ORTHOPEDICS CORPORATION DBA Conventus Flower: FDA-registered device maker in Horsham, PA, United States, 11 510(k) clearances

FLOWER ORTHOPEDICS CORPORATION DBA Conventus Flower is registered with the FDA (registration 3009996260) in Horsham, PA, United States. It lists 18 device types. The FDA files 11 510(k) clearances under its listings, the newest dated November 22, 2024. 8 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3009996260
Address
100 Witmer Rd Ste 280, Horsham, PA, United States, 19044
Owner or operator
FLOWER ORTHOPEDICS CORPORATION (10044024)
Roles
Complaint file establishment, Specification developer
First device listed
February 28, 2013
Registered through
2026
Brand names listed
Flex-Thread Distal Fibula Intramedullary Nail System (5.5mm Nail & 1mm End Cap)

Devices it lists

DeviceProduct codeClassRoleSource
BenderHXW1Specification developeraccessdata.fda.gov
Bit, DrillHTW1Specification developeraccessdata.fda.gov
ClampHXD1Specification developeraccessdata.fda.gov
CountersinkHWW1Specification developeraccessdata.fda.gov
Gauge, DepthHTJ1Specification developeraccessdata.fda.gov
Kit, Surgical Instrument, DisposableKDD1Specification developeraccessdata.fda.gov
Orthopedic Manual Surgical InstrumentLXH1Specification developeraccessdata.fda.gov
Passer, Wire, OrthopedicHXI1Specification developeraccessdata.fda.gov
Plate, Fixation, BoneHRS2Specification developeraccessdata.fda.gov
ReamerHTO1Specification developeraccessdata.fda.gov
RetractorGAD1Specification developeraccessdata.fda.gov
Rod, Fixation, Intramedullary And AccessoriesHSB2Specification developeraccessdata.fda.gov
Screw, Fixation, BoneHWC2Complaint file establishment, Specification developeraccessdata.fda.gov
ScrewdriverHXX1Specification developeraccessdata.fda.gov
Tap, BoneHWX1Specification developeraccessdata.fda.gov
TemplateHWT1Specification developeraccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Specification developeraccessdata.fda.gov
Washer, Bolt NutHTN2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
November 22, 2024K233567OsteoCoil™ Nitinol Compression System (Multiple Component PNs)HWCSubstantially EquivalentFlower Orthopedics Corporation Dba Conventus Flower Orthoaccessdata.fda.gov
November 21, 2022K222390Flex-Thread™ Ulna Intramedullary Nail SystemHSBSubstantially EquivalentFlower Orthopedics Corporation Dba Conventus Floweraccessdata.fda.gov
July 23, 2021K212030Flex-Thread™ Distal Fibula lntramedullary Nail SystemHSBSubstantially EquivalentFlower Orthopedics Corporation Dba Conventus Floweraccessdata.fda.gov
January 22, 2021K202858Flex-ThreadTM Distal Fibula Intramedullary Nail SystemHSBSubstantially EquivalentConventus Orthopaedics, LLCaccessdata.fda.gov
July 26, 2019K191817ActivOrtho Continuous Compression Screw SystemHWCSubstantially EquivalentActivortho, Inc.accessdata.fda.gov
June 6, 2017K170687Flower Bone Screw SetHWCSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov
March 27, 2014K133930FLOWER REAR FOOT PLATING SET, FLOWER CALCANEUS PLANTING SET, FLOWER REARFOOT PLATING SETHRSSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov
November 18, 2013K133102FLOWER ANKLE PLATING SETHRSSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov
October 30, 2013K132248FLOWER BONE SCREW SETHWCSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov
August 22, 2013K131657FLOWER SMALL AND MEDIUM IMPLANT SETHRSSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov
March 29, 2013K123562FLOWER SMALL AND MEDIUM BONE IMPLANTSHRSSubstantially EquivalentFlower Orthopedics Corporationaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
August 29, 202393024Class IIOngoingCoventus Flower Orthopedics Flex-Thread TM 3.2mm Cannulated Reamer-used to ream and subsequently open the intramedullary canal to the appropriate depth for nail insertion; Flex-Thread TM 3.2mm is provided sterile, singleDevice is breaking while in use, potential for patients to require a revision surgery.accessdata.fda.gov
November 2, 202189092Class IITerminatedFlex-Thread Inserter Shaft intended for Fibula intramedullary-intended to be used with the Inserter Draw Rod and Blue Ratchet Handle in order to facilitate the insertion of the Flex-Thread Nail System- Catalog Number: 84Mating incompatibility between the Inserter Shaft and the Inserter Draw Rod causing the inserter draw rod to bind and not rotate freely as intended surgeon may be unable to complete surgery unless a second set is availableaccessdata.fda.gov
September 3, 202188724Class IITerminatedFlower E-Kit, Advanced-Bone Fixation Fasterner-Fixation of Ref: EWK 201Product kit missing CDG 200 (Cannulated Countersink for 3.0-4.5mm Screws) from EWK 201 (Flower E-Kit, Advanced)accessdata.fda.gov
September 1, 202188669Class IITerminatedFlower Drill Bit Kit 2.0 mm - intended to be used with solid 2.0mm screws and can be used with any plate that has been cleared as part of the Flower Small and Medium Implant Set and uses the small locking mechanism. mechDrill bits packaged in kits are missing the AO connect feature and may result in delay of procedureaccessdata.fda.gov
April 15, 202187906Class IITerminatedT25 Cannulated Screwdrivers (CSD 025) packaged in Guide Wire Kits (GWK 300) - Product Usage: Intended to be used to insert screws with T25 driving features, which includes screws with diameters of 5.5mm, 6.5mm, and 7.3mmCannulated Screwdrivers may break at the driver tip along the shaft, near the handle extending surgery time and additional x-ray to identify the fragments from the breakagesaccessdata.fda.gov
July 8, 202086023Class IITerminatedCalcaneus Plate, Extensile, Small, Left, Catalog Number CPF 101 - Product Usage: intended to be used for internal fixation of fractures and reconstruction of bones of the rearfoot, including the calcaneus.The contract manufacturer of the calcaneus plate inadvertently used the incorrect material to manufacture the plates (a titanium alloy rather than pure titanium).accessdata.fda.gov
December 22, 201676156Class IITerminatedCannulated Drill bit 2.0mm and 2.6 mm; Used in conjunction with the Flower Bone Screw Set.The product is being recalled due to incidence and reports of the product breaking during surgery.accessdata.fda.gov
February 16, 201570578Class IITerminatedVariable Angle Locking Peg, D:1.8mm x L:14.0mm; Variable Angle Locking Peg, D:1.8mm x L:16.0mm, Variable Angle Locking Peg, D:1.8mm x L:18.0mm; Variable Angle Locking Peg, D:1.8mm x L:20.0mm; Variable Angle Locking Peg, Locking pegs were not locking during distal radius procedures. There has been one (1) report of revision surgery scheduled to remove a loosened peg.accessdata.fda.gov

Compare with other makers

Updated November 22, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.