Data / Medical devices / United States / FHC, Inc.

FHC, Inc.: FDA-registered device maker in Bowdoin, ME, United States, 15 510(k) clearances

FHC, Inc. is registered with the FDA (registration 3002250546) in Bowdoin, ME, United States. It lists 7 device types. The FDA files 15 510(k) clearances under its listings, the newest dated September 8, 2023. 9 recall events name it as the recalling firm (1 Class I). Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3002250546
Address
1201 Main ST, Bowdoin, ME, United States, 04287
Owner or operator
FHC, Inc. (9037838)
Roles
Complaint file establishment, Manufacturer
First device listed
April 10, 2006
Registered through
2027
Brand names listed
DP Stylet 5x 204mm, MICROTARGETING DRIVE SYSTEM, MICROTARGETING GUIDELINE 4000, NexDrive™, NexFrame™, Nexprobe™, Passive Headrest, STarFix Designer Software and more

Devices it lists

DeviceProduct codeClassRoleSource
Electrode, DepthGZL2Manufactureraccessdata.fda.gov
Electrosurgical, Cutting & Coagulation & AccessoriesGEI2Manufactureraccessdata.fda.gov
Holder, Head, Neurosurgical (Skull Clamp)HBL2Manufactureraccessdata.fda.gov
Instrument, Surgical, Non-PoweredHAO1Manufactureraccessdata.fda.gov
Neurological Stereotaxic InstrumentHAW2Complaint file establishment, Manufactureraccessdata.fda.gov
Stylet, Surgical, General & Plastic SurgeryGAH1Manufactureraccessdata.fda.gov
Surgical Planning Software For Neurological Stereotaxic InstrumentsQRI2Complaint file establishment, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
September 8, 2023K231141STarFix Designer Software C0265QRISubstantially EquivalentFHC, Inc.accessdata.fda.gov
May 14, 2020K200169VFS1 Bipolar Electrosurgical GeneratorGEISubstantially EquivalentFHC, Inc.accessdata.fda.gov
December 20, 2018K183123microTargeting Guideline 4000 5.0 SystemGZLSubstantially EquivalentFHC, Inc.accessdata.fda.gov
July 26, 2012K121950MICROTARGETING XL STAR DRIVE SYSTEMHAWSubstantially EquivalentFHC, Inc.accessdata.fda.gov
February 12, 2010K092192WAYPOINT STEREOTACTIC SYSTEMHAWSubstantially EquivalentFHC, Inc.accessdata.fda.gov
September 18, 2009K092562MICROTARGETING STAR DRIVE SYSTEM, COMPONENTSHAWSubstantially EquivalentFHC, Inc.accessdata.fda.gov
July 25, 2007K071364MICROTARGETING GUIDELINE 4000GZLSubstantially EquivalentFHC, Inc.accessdata.fda.gov
October 4, 2004K040334NAVIGUS PASSIVE PROBE, MODEL NP-1000HAWSubstantially EquivalentImage-Guided Neurologics, Inc.accessdata.fda.gov
March 24, 2004K033173MICRO TARGETING ELECTRODEGZLSubstantially EquivalentFHC, Inc.accessdata.fda.gov
March 2, 2004K033619NAVIGUS UNIBODY FIDUCIAL MARKER SYSTEM, MODEL FM-4000HAWSubstantially EquivalentImage-Guided Neurologics, Inc.accessdata.fda.gov
August 21, 2003K031885NAVIGUS PASSIVE HEAD RESTRAINT SYSTEM, MODEL HR-XXXHBLSubstantially EquivalentImage-Guided Neurologics, Inc.accessdata.fda.gov
September 25, 2002K022100NAVIGUS MANUAL DISPOSABLE MICRODRIVE WITH DIGITAL DISPLAY, MODELS MI-1000 & MI-1010HAWSubstantially EquivalentImage-Guided Neurologics, Inc.accessdata.fda.gov
October 1, 2001K012366NAVIGUS II TRAJECTORY GUIDEHAWSubstantially EquivalentImage-Guided Neurologics, Inc.accessdata.fda.gov
August 30, 2001K011775MICRO TARGETING DRIVE SYSTEMHAWSubstantially EquivalentFHC, Inc.accessdata.fda.gov
August 14, 2001K011992FHC MICROTARGETING DRIVE SYSTEMHAWSubstantially EquivalentFHC, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
October 4, 202495479Class IOngoingmicroTargeting Insertion Tube Set, P/N 66-IT-05P, Lot 244517. The intended use is to accurately guide a microelectrode or instrument in the brain during stereotactic functional neurosurgical procedures.A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging accessdata.fda.gov
June 17, 202085897Class IITerminatedFHC Guideline 4000 5.0 GL5 Main Processing Unit - Product Usage: intended to record and stimulate electrophysiological activity, as well as aid in the accurate placement of electrodes and other instruments. Catalogue NumAn electrical sub-circuit was not properly connected. Its purpose is to eliminate the possibility of interference with proper performance of the Guideline 5 Main Processing Unit, if an ESD event (greater than 6kV) were to occur.accessdata.fda.gov
May 10, 201880148Class IITerminatedmicroTargeting" Drive System, Product Number MT-DSThe FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.accessdata.fda.gov
March 30, 201055287Not yet classifiedTerminatedmicroTargeting Drive System with Mounted Accessories Catalog numbers : 66-ZD-MD-01, MT-DS-01, FC1006 (Medtronic) Product is the FHC DBS Depth Stop Adapter, a component of the microTargeting Drive and the STar Drive. The Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.accessdata.fda.gov
December 28, 200954278Not yet classifiedTerminatedFHC microTargeting Guideline 4000 ver 1.4 (GL4K) Software, Catalog # MT-GL4K. Intended to assist in functional neurological procedures.The raster tab for the GL4K version 1.4 software may assign incorrect depths for waveform recordings and if used to identify the implantation target for the DBS lead, the implant may be placed in the wrong location.accessdata.fda.gov
October 20, 200850103Not yet classifiedTerminatedFHC MicroTargeting Electrode, MTDWBP(AR)(MP I ) Intended for use in intra-operative recording of single unit neuronal activity or intra-operative stimulation of neural elements in the brain.Mislabeled: May contain an electrode longer than labeled sizeaccessdata.fda.gov
October 8, 200850086Not yet classifiedTerminatedFHC microTargeting Platform DBS Measuring Fixture, a component of the micro-targeting Drive System (Catalog Number 66-FA-SF). The device is a stereotactic instrument used for the placement of recording and stimulating elMeasuring fixture is incorrectly graduated.accessdata.fda.gov
October 31, 200533946Not yet classifiedTerminatedFHC microTargeting Power Assist System used with the micro Targeting Drive System, models: 66-DA-ME; 66EL-MC; 66EL-MS;66EL-MS-02; 66-EL-MS-03; 66-EL-RM; MT-DS-AM; MT-DS-MD.Power Assist microTargeting System may advance beyond intended targetaccessdata.fda.gov
March 14, 200531718Not yet classifiedTerminatedFHC 66-ZD-MD microTargeting Drive System: System for Stereotactic Positioning Used with the Power Assist (66-DA-ME) or Display Assembly (66-DA-EN)Potential for non-sterile pin to contaminate sterile fieldaccessdata.fda.gov

Compare with other makers

Updated November 8, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.