EOS imaging: FDA-registered device maker in Paris, France, 5 510(k) clearances

EOS imaging is registered with the FDA (registration 3006165260) in Paris, France. It lists 4 device types. The FDA files 5 510(k) clearances under its listings, the newest dated November 14, 2025. 6 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3006165260
Address
32 rue Blanche, Paris, France, 75009
Owner or operator
EOS imaging (10022240)
Roles
Manufacturer
First device listed
July 13, 2016
Registered through
2027
Brand names listed
AutoDensity, EOSedge, EOSedge chair, Radiolucent chair, VEA Align, spineEOS, sterEOS

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
November 14, 2025K251078AutoDensityQIHSubstantially EquivalentEos Imagingaccessdata.fda.gov
August 15, 2025K251747VEA Align; spineEOSQIHSubstantially EquivalentEos Imagingaccessdata.fda.gov
August 6, 2024K233920EOSedgeKPRSubstantially EquivalentEos Imagingaccessdata.fda.gov
June 25, 2024K240582VEA Align; spineEOSQIHSubstantially EquivalentEos Imagingaccessdata.fda.gov
June 19, 2018K172346sterEOS WorkstationLLZSubstantially EquivalentEos Imagingaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
December 22, 202087505Class IITerminatedThe EOSedge system may acquire two simultaneous orthogonal planar images for a standing or seated patient at low dose. The scan length is defined by the user and may cover the whole body or a specific area (spine, lower Inadequate images resizing and 2D measurement errors may occur when biplanar acquisition has been performed with patient orientation different from AP (Antero-Posterior).accessdata.fda.gov
August 1, 201880938Class IITerminatedsterEOS workstation3D projections may be incorrect when the pair of images used is a secondary capture generated from a series containing more than two images, where one of the images has been manually flipped. Projection errors may lead to errors in calculation of 3D clinical parameters when adjusting the position, size and shape of the 3D objects used. Incorrect clinical paraccessdata.fda.gov
May 30, 201777424Class IITerminatedROTH MOBELI Grab Handles used with EOS System: MOBELI Stabi Vario Grab Handle, ROTH Catalogue Number 14002 96 S, EOS Imaging Catalogue Number 9000111773; and MOBELI Dual Grip Grab Handle, ROTH Catalogue Number 14002 25 SROTH MOBELI grab handles could detach and patient could fall if the EOS system operator does not follow instructions. Before each use, the operator must examine the vacuum safety indicator to check the vacuum is monitored and sufficient and the grab handle correctly attached. Do not use grab handles to help patient up. The handles are only for stabilizing thaccessdata.fda.gov
November 29, 201366980Class IITerminatedsteroEOS Workstation with software versions: 1.3, 1.4 and 1.5 used in processing 3D X-ray images Product Usage: The sterEOS Workstation is a general system for acceptance, transfer, display and digital processing of two Error copying information to the clinical file and to the report when two 3D models are opened simultaneously on the sterEOS workstationaccessdata.fda.gov
November 7, 201366833Class IITerminatedEOS System X- ray beam Digital radiography system used in general radiographic examinations.EOS imaging discovered during production internal testing that the X-ray beam collimation set up by the operator at the user interface of the acquisition workstation is different from the actual collimation of the X-ray beam operated by the EOS system during the X-ray acquisition.accessdata.fda.gov
April 13, 201158560Not yet classifiedTerminatedSoftware versions Eos software versions: 1.2.4, 1.2.5, 1.2.6,1.2.7,1.2.8, 1.2.9,1.2.10,.2.11,1.2.12, 1.2.13, 1.3.2,1.3.3, 1.3.4, 1.4.0, 1.4.1, 1.4.2. sterEOS software versions: 1.2.3.3788, 1.2.4.4286, 1.3.2.3373, 1.3.3.3Print true size, print requests from the EOS acquisition station or the sterEOS image review station may, in certain cases, be affected by a different enlargement factor during printing. Taccessdata.fda.gov

Compare with other makers

Updated November 14, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.