Data / Medical devices / United Kingdom / Endomagnetics Ltd
Endomagnetics Ltd: FDA-registered device maker in Cambridge Cambridgeshire, United Kingdom, 5 510(k) clearances and 1 PMA approval
Endomagnetics Ltd is registered with the FDA (registration 3012644426) in Cambridge Cambridgeshire, United Kingdom. It lists 3 device types. The FDA files 5 510(k) clearances and 1 PMA approval under its listings, the newest dated June 28, 2024. 1 recall event names it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3012644426
- Address
- 330 Cambridge Science Park Milton Road, Cambridge Cambridgeshire, United Kingdom, CB4 0WN
- Owner or operator
- HOLOGIC, INC. (9007676)
- Roles
- Complaint file establishment, Specification developer
- First device listed
- December 8, 2025
- Registered through
- 2027
- Brand names listed
- Magseed, Magseed Pro, Magtrace, Sentimag Cart
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Lymph Node Location System During Sentinel Biopsy Procedure | PUV | 3 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Marker, Radiographic, Implantable | NEU | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Temporary Tissue Marker | PBY | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| June 28, 2024 | K232865 | Magseed Pro Magnetic Marker System | NEU | Substantially Equivalent | Endomagnetics Ltd., | accessdata.fda.gov |
| January 21, 2023 | K222832 | Sentimag System | NEU | Substantially Equivalent | Endomagnetics Ltd., | accessdata.fda.gov |
| February 16, 2018 | K173587 | Magseed Magnetic Marker Systtem | NEU | Substantially Equivalent | Endomagnetics Ltd., | accessdata.fda.gov |
| January 13, 2017 | K163541 | Magseed Magnetic Marker System | PBY | Substantially Equivalent | Endomagnetics Ltd., | accessdata.fda.gov |
| March 2, 2016 | K153044 | Sentimag System, Sentimark Magnetic Marker Systerm | PBY | Substantially Equivalent | Endomagnetics Ltd., | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| July 24, 2018 | P160053 | MagtraceTM and Sentimag(R) Magnetic Locatization System | PUV | 10 | May 18, 2026 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 1, 2025 | 97680 | Class II | Ongoing | Magseed Pro 7 cm soft tissue marker. Model Number: MS2-17-1-07. Product Description: The Endomag Magseed Pro Magnetic Marker System is a sterile, single use device composed of a marker preloaded in a 17ga Needle Delivery | Potential for contamination with cotton fibers. | accessdata.fda.gov |
Compare with other makers
Updated May 18, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.