Skip to the page

Data / Medical devices / United States / Encision, Inc.

Encision, Inc.: FDA-registered device maker in Boulder, CO, United States, 8 510(k) clearances

Encision, Inc. is registered with the FDA (registration 1722040) in Boulder, CO, United States. It lists 1 device type. The FDA files 8 510(k) clearances under its listings, the newest dated July 15, 2020. 8 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1722040
FEI number
1000117361
Address
6797 Winchester Cir., Boulder, CO, United States, 80301
Owner or operator
ENCISION, INC. (9003185)
Roles
Manufacturer, Specification developer
First device listed
November 28, 2007
Registered through
2026
Brand names listed
AEM Burn Protection Disposable System Cable, AEM Cord Adapter, AEM Disposable Monopolar Laparoscopic Electrodes, Cords, and Handpiece, AEM Endoshield 2 Burn Protection System, AEM e-Edge Disposable Scissor Inserts, AEM enTouch 2X Scissor, AEM enTouch Handles, Disposable AEM Cord and more

Devices it lists

DeviceProduct codeClassRoleSource
Electrosurgical, Cutting & Coagulation & AccessoriesGEI2Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
July 15, 2020K201018Encision AEM enTouch 2X ScissorGEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
March 20, 2020K191612Encision AEM Monopolar Laparoscopic Instruments and AccessoriesGEISubstantially EquivalentEncision Incorporatedaccessdata.fda.gov
June 16, 2014K140006ENDOSHIELD BURN PROTECTION SYSTEMGEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
January 10, 2013K122383EM3 AEM MONITOR AEM CONNECTORSGEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
August 20, 2010K093622AEM MONITORING SYSTEM, MODELS EM2, EMR, ES4007, ES4107, ES9005 AND ES9015GEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
June 9, 2010K100711SUCTION IRRIGATION ELECTRODES AND ADAPTERSGEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
August 17, 2009K091074AEM DISPOSABLE ELECTRODES,MODEL ESO300 SERIESGEISubstantially EquivalentEncision, Inc.accessdata.fda.gov
December 30, 1991K912780MONOPOLAR LAPAROSCOPIC ELECTRODES W/ELETROSHIELDGEISubstantially EquivalentElectroscope, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
June 15, 201261529Class IITerminatedAEM Disposable Electrodes, Device, Electrosurgical, Cutting and Coagulation and Accessories. AEM Disposable Electrodes used as electrosurgical accessories intended for ablation, removal, resection and coagulation of softEncision is performing a field correction to their AEM Disposable Electrodes due to two consumer complaints reporting unanticipated alarms from the AEM monitor while using the device. This issue could result delays or complications during surgical procedures.accessdata.fda.gov
August 24, 201159781Not yet classifiedTerminatedEncision AEM Suction Irrigation Electrode, L-Diamond, REF ES3881. Encision Inc., Boulder, CO 80301. The Suction Irrigation Electrodes and Adapters combine AEM shielding technology with suction and irrigation of fluids duElectrode tips have been reported breaking off during use or cleaning.accessdata.fda.gov
April 7, 201158518Not yet classifiedTerminatedES0101, AEM Disposable Curved Scissors, 1/2", 35cm, Sterile R, Encision Inc., Boulder, CO 80301 Cutting tissue during electrosurgical proceduresSterility may be compromised due to holes in packaging.accessdata.fda.gov
April 5, 201055286Not yet classifiedTerminatedAEM Disposable Electrode, Spatula, 35cm, REF ES0301, Qty: 10 each Sterile R, Manufactured for: Encision Inc., Boulder, CO 80301, made in Taiwan. Electrosurgical accessories intended, by use of monopolar high-frequency elElectrosurgical electrode tip insulation may crack and break off during use.accessdata.fda.gov
July 9, 200429563Not yet classifiedTerminatedEncision ES4107 Disposable AEM Cord, Sterile.Firm found pinholes in packaging which would compromise sterility.accessdata.fda.gov
June 11, 200429430Not yet classifiedTerminatedAEM Fixed-Tip L-Diamond Electrode, 5mm, Reusable.Electrosurgical tip may break or come off during use.accessdata.fda.gov
June 23, 200326604Not yet classifiedTerminatedEM2 NC AEM Monitor (NON-COM)Use of NC versions of AEM monitor presents burn hazard when used with single pad and capacitively coupled patient return electrodes.accessdata.fda.gov
January 15, 200325368Not yet classifiedTerminatedAEM Fixed-Tip Needle Electrode - 5mm, Reusable REF/CAT ES3521BReports of needle fixed-tip electrodes becoming loose or breaking off.accessdata.fda.gov

Compare with other makers

Updated July 15, 2020. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.