Skip to the page

Data / Medical devices / United States / Dynarex Corp.

Dynarex Corp.: FDA-registered device maker in Middletown, NY, United States, 6 510(k) clearances

Dynarex Corp. is registered with the FDA (registration 2431014) in Middletown, NY, United States. It lists 5 device types. The FDA files 6 510(k) clearances under its listings, the newest dated October 3, 2016. 5 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2431014
Address
11 Dynarex Drive, Middletown, NY, United States, 10941
Owner or operator
DYNAREX CORP. (2431014)
Roles
Specification developer
First device listed
December 19, 2007
Registered through
2027
Brand names listed
3380 - Eye Cups, Non-Sterile, 50/6/Cs, 3401 - Packing Strips Plain, Sterile, 1/4"¿ x 5 yds, 12/Cs, 3402 - Packing Strips Plain, Sterile, 1/2"¿ x 5 yds, 12/Cs, 3403 - Packing Strips Plain, Sterile, 1"¿ x 5 yds, 12/Cs, 3404 - Packing Strips Plain, Sterile, 2"¿ x 5 yds, 12/Cs, 3411 - Packing Strips Iodoform, Sterile, 1/4"¿ x 5 yds, 12/Cs, 3412 - Packing Strips Iodoform, Sterile, 1/2"¿ x 5 yds, 12/Cs, 3413 - Packing Strips Iodoform, Sterile, 1" x 5 yds, 12/Cs and more

Devices it lists

DeviceProduct codeClassRoleSource
Cup, EyeLXQUSpecification developeraccessdata.fda.gov
Dressing, Wound, DrugFROUSpecification developeraccessdata.fda.gov
Polymer Patient Examination GloveLZA1Specification developeraccessdata.fda.gov
Tubes, Gastrointestinal (And Accessories)KNT2Specification developeraccessdata.fda.gov
Valve, Non-RebreathingCBP2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
October 3, 2016K152970Dynarex Xeroform Petrolatum DressingFROSubstantially EquivalentDynarex Corporationaccessdata.fda.gov
September 1, 2015K151575Dynarex Eye CupsLXQSubstantially EquivalentDynarex Corporationaccessdata.fda.gov
January 9, 2009K082863DYNAREX ENTERAL DELIVERY PUMP SET WITH SPIKE (1000ML), DYNAREX ENTERAL FEEDING SETS FOR GRAVITY AND PUMP USE (1000ML)KNTSubstantially EquivalentDynarex Corporationaccessdata.fda.gov
September 12, 2008K081569DYNAREX/TILLOTSON NON-STERILE POWDER FREE BLUE NITRILE PATIENT EXAM GLOVE FOR USE WITH CHEMOTHERAPY DRUGSLZASubstantially EquivalentDynarex Corporationaccessdata.fda.gov
December 22, 2005K052743DYNAREX CPR SHIELD WITH ONE WAY VALVE AND BARRIER FILTER, MODEL 4921CBPSubstantially EquivalentDynarex Corp.accessdata.fda.gov
October 17, 2002K012816DYNAREX IODOFORM PACKING STRIPS, MODELS 3411, 3412, 3413, 3414FROSubstantially EquivalentDynarex Corp.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 8, 201880058Class IITerminatedDynarex CGA870 All Brass Oxygen Regulator, All Brass - 0-25 LPM, Barb & 2-DISS Outlet, UPC: 616784522715, Model Number 5227 A pressure regulator is a device, often called a pressure-reducing valve, that is intended for mThe device is equipped with a dial that has an inaccurate flow rate indicator.accessdata.fda.gov
March 3, 201673584Class IITerminateddynarex Specimen Containers, Screw-On, Leak-Resistant Lid, Tamper-Evident Seal, Sterile, Single Use Only Product Usage:containers for sample collectionExterior carton is mis-labeled as Sterile. Non-sterile, bulk specimen containers were packed in incorrect exterior carton.accessdata.fda.gov
July 2, 201468681Class IITerminatedCPR Shield With One Way Valve and Barrier Filter, Reorder No. 4921 --- Dynarex label, 100 per case --- Manufactured for: Dynarex Corporation - Made in China. Used as a physical barrier for mouth to mouth resuscitation."THIS SIDE UP" is on the wrong side of the product. This error poses a potential health hazard if the wrong labeling is followed by caregivers.accessdata.fda.gov
May 10, 200429031Not yet classifiedTerminated100 Sheer Plastic Spot Bandages, 7/8" Dia. (22 mm). Reorder No. 3607. Manufactured for dynarex Corporation, Orangeburg, NY 10962. Sterile with non-stick pad. 100% Latex Free Bandage & Wrapper. 48 boxes of 100 bandages peBandages labeled as "100% Latex Free" may contain latex. The wrapper was analytically tested by a private laboratory and found to contain latex.accessdata.fda.gov
December 31, 200225310Not yet classifiedTerminatedEar Loop Procedure Masks, For one time use only, Glass-Free, Reorder No. 2201, packed in a cardboard box (unit box). Manufactured for dynarex Corporation, Brewster, NY 10509. Made in China. Product is labeled with a LateProduct labeled as 'latex free' but recent tests indicate that it contains minute amounts of latex.accessdata.fda.gov

Compare with other makers

Updated October 3, 2016. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.