Data / Medical devices / United States / Draeger Medical Systems, Inc.
Draeger Medical Systems, Inc.: FDA-registered device maker in Telford, PA, United States, 10 510(k) clearances
Draeger Medical Systems, Inc. is registered with the FDA (registration 2510954) in Telford, PA, United States. It lists 5 device types. The FDA files 10 510(k) clearances under its listings, the newest dated January 17, 2025. 13 recall events name it as the recalling firm (3 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 2510954
- Address
- 3135 Quarry RD., Telford, PA, United States, 18969
- Owner or operator
- Draeger Medical Systems, Inc. (9070398)
- Roles
- Manufacturer, Repackager or relabeler, Specification developer
- First device listed
- December 14, 2007
- Registered through
- 2026
- Brand names listed
- Babyroo TN300, BiliLux Phototherapy Light, C2HS Isolette Infant Incubator, Isolette 8000 plus, Isolette 8000 plus Infant Incubator, Jaundice Meter-JM105, RW Resuscitaire, TI500 Globetrotter Transport System and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Bilirubin (Total And Unbound) In The Neonate Test System | MQM | 1 | Repackager or relabeler, Specification developer | accessdata.fda.gov |
| Incubator, Neonatal | FMZ | 2 | Manufacturer | accessdata.fda.gov |
| Incubator, Neonatal Transport | FPL | 2 | Manufacturer | accessdata.fda.gov |
| Unit, Neonatal Phototherapy | LBI | 2 | Repackager or relabeler, Specification developer | accessdata.fda.gov |
| Warmer, Infant Radiant | FMT | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| January 17, 2025 | K243606 | Babyroo TN300 | FMT | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| May 30, 2023 | K230278 | Babyroo TN300 | FMT | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| November 21, 2018 | K182977 | Isolette 8000 Plus | FMZ | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| May 1, 2018 | K172656 | BiliLux | LBI | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| April 19, 2018 | K172154 | Isolette 8000 plus | FMZ | Substantially Equivalent | Draeger Medical Sytems, Inc. | accessdata.fda.gov |
| November 13, 2014 | K133175 | DRAEGER JAUNDICE METER JM-105 | MQM | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| November 2, 2012 | K120642 | RESUSCITAIRE WITH AUTOBREATH | FMT | Substantially Equivalent | Draeger Medical Systems, Inc. | accessdata.fda.gov |
| July 13, 2000 | K001242 | ISOLETTE INFANT INCUBATOR, MODEL C2HS | FMZ | Substantially Equivalent | Hill-Rom Air-Shields | accessdata.fda.gov |
| April 27, 2000 | K001019 | TI500 GLOBE-TROTTER TRANSPORT SYSTEM | FPL | Substantially Equivalent | Hill-Rom Air-Shields | accessdata.fda.gov |
| June 10, 1994 | K941106 | MODEL TI500 ISOLETTE INFANT INCUBATOR | FPL | Substantially Equivalent | Air-Shields, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| May 16, 2023 | 92353 | Class II | Ongoing | Draeger Softbed Resuscitaire and/or Birthing Room Warmer with Scale [Model(s): RW82VHA-1, RW82VHA-1C, RW82VHA-1D, RW82-1, RW82-1C, RW82-1D, WBR82-1 and WBR82-1C] | The Resuscitaire Infant Radiant Warmer with the optional scale could display inaccurate weight values. | accessdata.fda.gov |
| May 20, 2022 | 90423 | Class II | Ongoing | Draeger Globe-Trotter and Globe-Trotter IC, Model numbers MS20508 and MS20509. neonatal transport system | The firm has initiated this recall to replace component on devices distributed containing a component within the oxygen supply system that is not rated to the working pressure of the system. | accessdata.fda.gov |
| May 15, 2018 | 79963 | Class I | Terminated | Draeger Jaundice Meter JM-103 The device is intended for use in hospitals, clinics or doctor s offices under a physician s supervision / direction to assist clinicians in monitoring of newborn infants. The device is not | Users have misinterpreted the display for out of range measurement indicated by the blinking" ---" to mean a zero measurement. | accessdata.fda.gov |
| March 5, 2014 | 67677 | Class I | Terminated | Draeger Oxylog 3000 plus ventilators, emergency and transport ventilator. Part number: 5704833 | The potentiometers (knobs) for setting the ventilation parameters may have contact interrupted and the device discontinues ventilation, gives an audible alarm and displays the error message Poti unplugged. | accessdata.fda.gov |
| February 7, 2014 | 67502 | Class I | Terminated | Draeger PS500 Power Supply Unit of the Infinity ACS Workstation Critical Care (Evita Infinity V500), Evita V500 and /or Babylog VN500 Ventilators, used for ventilation during short term transport of patients within a hos | The battery capacity of the optional PS500 Power Supply Unit of the Infinity ACS Workstation Critical Care (Evita Infinity V500) did not last as long as expected. | accessdata.fda.gov |
| December 10, 2013 | 67056 | Class II | Terminated | Draeger Infinity Acute Care System Monitoring Solution | After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit. | accessdata.fda.gov |
| July 2, 2012 | 62470 | Class II | Terminated | Drager PT 4000 Phototherapy System | A routine internal quality check found that the Drager PT 4000 Phototherapy System is fitted with a 16 Amp rated fuse instead of the specified 1.6 Amp rated fuse. This may mean that the internal fuse would not trip promptly in the event of an internal short-circuit. The possible consequence is the wall outlet circuit breaker would trip first on the device ma | accessdata.fda.gov |
| July 29, 2011 | 59568 | Not yet classified | Terminated | Infinity Delta Portable Patient Monitor. Draeger Medical Systems, Inc. Portable monitor used to monitor vital signs of neonatal, pediatric, and adult patients for bedside and transport applications. | Monitor keys may spontaneously become inoperative or active. This may cause a membrane switch panel malfunction, which could result in the monitor discharging a patient automatically. | accessdata.fda.gov |
| August 26, 2010 | 56676 | Not yet classified | Terminated | Fabius GS Anesthesia Machine, OR/Anesthesia, Draeger Medical, Inc., 3135 Quarry Road, Telford, PA 18969 inhalation anesthesia machine for use in operating, induction and recovery rooms | potential failures to Electri-Cord Manufacturing AC power cord | accessdata.fda.gov |
| August 19, 2010 | 56600 | Not yet classified | Terminated | Oxylog 3000, Emergency and Transport Ventilator; Catalog #2M86300; Drager Medical Inc., 3135 Quarry Road, Telford, PA 18969. | Patients received insufficient ventilation. The Oxylog 3000 Instructions are inadequate relating to dead space volume. | accessdata.fda.gov |
| June 4, 2010 | 55870 | Not yet classified | Terminated | Infinity Delta/Gamma X XL Patient Monitor. Portable monitor used to monitor vital signs of neonatal, pediatric, and adult patients for bedside and transport applications. | Monitor keys may become inoperative or activate spontaneously, causing a membrane switch panel malfunction. This may discharge a patient automatically. | accessdata.fda.gov |
| July 29, 2009 | 52835 | Not yet classified | Terminated | Heater Elements for Resuscitaire Infant Radiant Warmers model numbers RW82, RW82 VHA, WBR82, and WMRW82, 120 volt configuration only. | Spark, flame and smoke: A mis-positioned crimp on heater element lead wire resulted in flame and smoke aerating from the top of the warmer assembly. | accessdata.fda.gov |
| July 17, 2009 | 52718 | Not yet classified | Terminated | Stabilet Infant Warming System, model numbers 200, 300, 1250, 1500, 200/3000, 2000, 2200/3200, 3000, and 3200. | Hot particles fell into the infant bassinet beneath a Radiant Infant Warmer. The resulting fire injured an infant. These devices are obsolete. | accessdata.fda.gov |
Compare with other makers
- All makers of Incubator, Neonatal
- All makers of Unit, Neonatal Phototherapy
- All makers of Warmer, Infant Radiant
- All makers of Incubator, Neonatal Transport
- All makers of Bilirubin (Total And Unbound) In The Neonate Test System
Updated January 17, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.