Draeger Medical Systems, Inc.: FDA-registered device maker in Telford, PA, United States, 10 510(k) clearances

Draeger Medical Systems, Inc. is registered with the FDA (registration 2510954) in Telford, PA, United States. It lists 5 device types. The FDA files 10 510(k) clearances under its listings, the newest dated January 17, 2025. 13 recall events name it as the recalling firm (3 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2510954
Address
3135 Quarry RD., Telford, PA, United States, 18969
Owner or operator
Draeger Medical Systems, Inc. (9070398)
Roles
Manufacturer, Repackager or relabeler, Specification developer
First device listed
December 14, 2007
Registered through
2026
Brand names listed
Babyroo TN300, BiliLux Phototherapy Light, C2HS Isolette Infant Incubator, Isolette 8000 plus, Isolette 8000 plus Infant Incubator, Jaundice Meter-JM105, RW Resuscitaire, TI500 Globetrotter Transport System and more

Devices it lists

DeviceProduct codeClassRoleSource
Bilirubin (Total And Unbound) In The Neonate Test SystemMQM1Repackager or relabeler, Specification developeraccessdata.fda.gov
Incubator, NeonatalFMZ2Manufactureraccessdata.fda.gov
Incubator, Neonatal TransportFPL2Manufactureraccessdata.fda.gov
Unit, Neonatal PhototherapyLBI2Repackager or relabeler, Specification developeraccessdata.fda.gov
Warmer, Infant RadiantFMT2Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
January 17, 2025K243606Babyroo TN300FMTSubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
May 30, 2023K230278Babyroo TN300FMTSubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
November 21, 2018K182977Isolette 8000 PlusFMZSubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
May 1, 2018K172656BiliLuxLBISubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
April 19, 2018K172154Isolette 8000 plusFMZSubstantially EquivalentDraeger Medical Sytems, Inc.accessdata.fda.gov
November 13, 2014K133175DRAEGER JAUNDICE METER JM-105MQMSubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
November 2, 2012K120642RESUSCITAIRE WITH AUTOBREATHFMTSubstantially EquivalentDraeger Medical Systems, Inc.accessdata.fda.gov
July 13, 2000K001242ISOLETTE INFANT INCUBATOR, MODEL C2HSFMZSubstantially EquivalentHill-Rom Air-Shieldsaccessdata.fda.gov
April 27, 2000K001019TI500 GLOBE-TROTTER TRANSPORT SYSTEMFPLSubstantially EquivalentHill-Rom Air-Shieldsaccessdata.fda.gov
June 10, 1994K941106MODEL TI500 ISOLETTE INFANT INCUBATORFPLSubstantially EquivalentAir-Shields, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 16, 202392353Class IIOngoingDraeger Softbed Resuscitaire and/or Birthing Room Warmer with Scale [Model(s): RW82VHA-1, RW82VHA-1C, RW82VHA-1D, RW82-1, RW82-1C, RW82-1D, WBR82-1 and WBR82-1C]The Resuscitaire Infant Radiant Warmer with the optional scale could display inaccurate weight values.accessdata.fda.gov
May 20, 202290423Class IIOngoingDraeger Globe-Trotter and Globe-Trotter IC, Model numbers MS20508 and MS20509. neonatal transport systemThe firm has initiated this recall to replace component on devices distributed containing a component within the oxygen supply system that is not rated to the working pressure of the system.accessdata.fda.gov
May 15, 201879963Class ITerminatedDraeger Jaundice Meter JM-103 The device is intended for use in hospitals, clinics or doctor s offices under a physician s supervision / direction to assist clinicians in monitoring of newborn infants. The device is not Users have misinterpreted the display for out of range measurement indicated by the blinking" ---" to mean a zero measurement.accessdata.fda.gov
March 5, 201467677Class ITerminatedDraeger Oxylog 3000 plus ventilators, emergency and transport ventilator. Part number: 5704833The potentiometers (knobs) for setting the ventilation parameters may have contact interrupted and the device discontinues ventilation, gives an audible alarm and displays the error message Poti unplugged.accessdata.fda.gov
February 7, 201467502Class ITerminatedDraeger PS500 Power Supply Unit of the Infinity ACS Workstation Critical Care (Evita Infinity V500), Evita V500 and /or Babylog VN500 Ventilators, used for ventilation during short term transport of patients within a hosThe battery capacity of the optional PS500 Power Supply Unit of the Infinity ACS Workstation Critical Care (Evita Infinity V500) did not last as long as expected.accessdata.fda.gov
December 10, 201367056Class IITerminatedDraeger Infinity Acute Care System Monitoring SolutionAfter a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.accessdata.fda.gov
July 2, 201262470Class IITerminatedDrager PT 4000 Phototherapy SystemA routine internal quality check found that the Drager PT 4000 Phototherapy System is fitted with a 16 Amp rated fuse instead of the specified 1.6 Amp rated fuse. This may mean that the internal fuse would not trip promptly in the event of an internal short-circuit. The possible consequence is the wall outlet circuit breaker would trip first on the device maaccessdata.fda.gov
July 29, 201159568Not yet classifiedTerminatedInfinity Delta Portable Patient Monitor. Draeger Medical Systems, Inc. Portable monitor used to monitor vital signs of neonatal, pediatric, and adult patients for bedside and transport applications.Monitor keys may spontaneously become inoperative or active. This may cause a membrane switch panel malfunction, which could result in the monitor discharging a patient automatically.accessdata.fda.gov
August 26, 201056676Not yet classifiedTerminatedFabius GS Anesthesia Machine, OR/Anesthesia, Draeger Medical, Inc., 3135 Quarry Road, Telford, PA 18969 inhalation anesthesia machine for use in operating, induction and recovery roomspotential failures to Electri-Cord Manufacturing AC power cordaccessdata.fda.gov
August 19, 201056600Not yet classifiedTerminatedOxylog 3000, Emergency and Transport Ventilator; Catalog #2M86300; Drager Medical Inc., 3135 Quarry Road, Telford, PA 18969.Patients received insufficient ventilation. The Oxylog 3000 Instructions are inadequate relating to dead space volume.accessdata.fda.gov
June 4, 201055870Not yet classifiedTerminatedInfinity Delta/Gamma X XL Patient Monitor. Portable monitor used to monitor vital signs of neonatal, pediatric, and adult patients for bedside and transport applications.Monitor keys may become inoperative or activate spontaneously, causing a membrane switch panel malfunction. This may discharge a patient automatically.accessdata.fda.gov
July 29, 200952835Not yet classifiedTerminatedHeater Elements for Resuscitaire Infant Radiant Warmers model numbers RW82, RW82 VHA, WBR82, and WMRW82, 120 volt configuration only.Spark, flame and smoke: A mis-positioned crimp on heater element lead wire resulted in flame and smoke aerating from the top of the warmer assembly.accessdata.fda.gov
July 17, 200952718Not yet classifiedTerminatedStabilet Infant Warming System, model numbers 200, 300, 1250, 1500, 200/3000, 2000, 2200/3200, 3000, and 3200.Hot particles fell into the infant bassinet beneath a Radiant Infant Warmer. The resulting fire injured an infant. These devices are obsolete.accessdata.fda.gov

Compare with other makers

Updated January 17, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.