Skip to the page

Data / Medical devices / Italy / Dambo SRL

Dambo SRL: FDA-registered device maker in Putignano Bari, Italy, 2 510(k) clearances and 5 PMA approvals

Dambo SRL is registered with the FDA (registration 3031983053) in Putignano Bari, Italy. It lists 6 device types. The FDA files 2 510(k) clearances and 5 PMA approvals under its listings, the newest dated December 18, 2020. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3031983053
Address
Via Maestri Del Lavoro, Putignano Bari, Italy, 70017
Owner or operator
Dambo SRL (10091247)
Roles
Exporter to the US, Repackager or relabeler
First device listed
July 31, 2024
Registered through
2026

Devices it lists

DeviceProduct codeClassRoleSource
Acid, Hyaluronic, IntraarticularMOZ3Exporter to the US, Repackager or relabeleraccessdata.fda.gov
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 DaysFOZ2Exporter to the US, Repackager or relabeleraccessdata.fda.gov
Implant, Dermal, For Aesthetic UseLMH3Exporter to the US, Repackager or relabeleraccessdata.fda.gov
Implant, Dermal, For Aesthetic Use In The HandsPKY3Exporter to the US, Repackager or relabeleraccessdata.fda.gov
Introducer, CatheterDYB2Exporter to the US, Repackager or relabeleraccessdata.fda.gov
Syringe, PistonFMF2Exporter to the US, Repackager or relabeleraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
December 18, 2020K201075BD Insyte Autoguard Shielded IV Catheter, BD Insyte Autoguard BC Shielded IV Catheter, BD Insyte Autoguard BC Pro Shielded IV CatheterFOZSubstantially EquivalentBecton, Dickinson and Companyaccessdata.fda.gov
December 19, 2016K162081BD 1ml Luer-lok Hypodermic Syringe, BD 1 mL Luer-Lok Hypodermic Syringe with BD Hypodermic Needle or BD Eclipse Hypodermic Needle, BD 1ml Luer-lok Insulin SyringeFMFSubstantially EquivalentBecton, Dickinson and Companyaccessdata.fda.gov

PMA approvals

Premarket approvals this establishment lists, with the supplements the FDA has decided since.

ApprovedPMA numberDeviceProduct codeSupplementsLatest decisionSource
August 29, 2017P170007DUROLANEMOZ15December 23, 2025accessdata.fda.gov
February 25, 2014P090031MONOVISCMOZ15August 8, 2023accessdata.fda.gov
December 22, 2006P050052RADIESSE INJECTABLE IMPLANTLMH169June 26, 2026accessdata.fda.gov
December 3, 2004P010029EUFLEXXA (1% SODIUM HYALURONATE)MOZ40September 2, 2026accessdata.fda.gov
January 24, 2001P980044SUPARTZ FXMOZ62September 4, 2026accessdata.fda.gov

Compare with other makers

Updated December 23, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.