Data / Medical devices / United States / D. E. Hokanson, Inc.
D. E. Hokanson, Inc.: FDA-registered device maker in Bellevue, WA, United States, 8 510(k) clearances
D. E. Hokanson, Inc. is registered with the FDA (registration 3019130) in Bellevue, WA, United States. It lists 5 device types. The FDA files 8 510(k) clearances under its listings, the newest dated August 6, 2004. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3019130
- Address
- 12840 Ne 21ST PL, Bellevue, WA, United States, 98005
- Owner or operator
- D. E. HOKANSON, INC. (3019130)
- Roles
- Contract manufacturer, Manufacturer
- First device listed
- June 30, 1992
- Registered through
- 2026
- Brand names listed
- AG101 AIR SOURCE FOR E20, AI6 Arterial Inflow System, CC17(TM) Contoured Thigh Cuff, CC22(TM) Contoured Thigh Cuff, DP2 Disposable Digit or Penile Cuff, DP2.5 Disposable Digit or Penile Cuff, E-20 RAPID CUFF INFLATOR, EC-6 PLETHYSMOGRAPH and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Blood Pressure Cuff | DXQ | 2 | Contract manufacturer, Manufacturer | accessdata.fda.gov |
| Echocardiograph | DXK | 2 | Manufacturer | accessdata.fda.gov |
| Plethysmograph, Impedance | DSB | 2 | Manufacturer | accessdata.fda.gov |
| Plethysmograph, Photoelectric, Pneumatic Or Hydraulic | JOM | 2 | Manufacturer | accessdata.fda.gov |
| System, Measurement, Blood-Pressure, Non-Invasive | DXN | 2 | Contract manufacturer, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| August 6, 2004 | K041689 | POLYURETHANE BLOOD PRESSURE CUFFS | DXQ | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| February 12, 2003 | K023707 | A16 BLOOD FLOW MEASUREMENT SYSTEM | JOM | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| August 26, 1998 | K982707 | EC6 PLETHYSMOGRAPH | JOM | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| November 15, 1993 | K932851 | DISPOSABLE PENILE BLOOD PRESSURE CUFFS | DXQ | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| March 6, 1991 | K905367 | E-20 RAPID CUFF INFLATOR | DXN | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| October 22, 1990 | K901592 | MODEL MD-5 DOPPLER | DXK | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| January 18, 1990 | K896034 | PROCORD MD3500 VASCULAR DIAGNOSTIC SYSTEM | DSB | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
| March 1, 1985 | K842067 | CALCULATING CUFF INFLATOR TD312 | DXN | Substantially Equivalent | D. E. Hokanson, Inc. | accessdata.fda.gov |
Compare with other makers
- All makers of Echocardiograph
- All makers of System, Measurement, Blood-Pressure, Non-Invasive
- All makers of Blood Pressure Cuff
- All makers of Plethysmograph, Photoelectric, Pneumatic Or Hydraulic
- All makers of Plethysmograph, Impedance
Updated August 6, 2004. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.