Skip to the page

Data / Medical devices / United States / Circadiance

Circadiance: FDA-registered device maker in Export, PA, United States, 9 510(k) clearances

Circadiance is registered with the FDA (registration 3006182632) in Export, PA, United States. It lists 5 device types. The FDA files 9 510(k) clearances under its listings, the newest dated March 15, 2017. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3006182632
Address
1010 Corporate Lane, Export, PA, United States, 15632
Owner or operator
Circadiance (10028090)
Roles
Specification developer
First device listed
December 29, 2008
Registered through
2026
Brand names listed
NepPAP System, SleepWeaver 3D Nasal Mask, SleepWeaver Advance Pediatric Nasal CPAP Mask, SleepWeaver Anew Full Face Soft Cloth PAP Mask, SleepWeaver ELAN Nasal CPAP Mask, SleepWeaver FeatherWeight Tube, SleepWeaver Nasal CPAP Mask, SmartMonitor 2 / Synergy-E and more

Devices it lists

DeviceProduct codeClassRoleSource
Mask, OxygenBYG1Specification developeraccessdata.fda.gov
Monitor, Apnea, Facility UseFLS2Specification developeraccessdata.fda.gov
Monitor, Apnea, Home UseNPF2Specification developeraccessdata.fda.gov
OximeterDQA2Specification developeraccessdata.fda.gov
Ventilator, Non-Continuous (Respirator)BZD2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
March 15, 2017K162905SleepWeaver 3D Nasal MaskBZDSubstantially EquivalentCircadiance, LLCaccessdata.fda.gov
April 5, 2016K151683SleepWeaver Advance Pediatric Nasal CPAP MaskBZDSubstantially EquivalentCircadiance, LLCaccessdata.fda.gov
May 24, 2013K130481SLEEPWEAVER ANEW FULL FACE SOFT CLOTH PAP MASKBZDSubstantially EquivalentCircadiance, LLCaccessdata.fda.gov
April 24, 2012K120757SLEEPWEAVER ELAN NASAL CPAP MASKBZDSubstantially EquivalentCircadiance, LLCaccessdata.fda.gov
March 30, 2011K103410NEOPAP SYSTEMBZDSubstantially EquivalentChildrens Medical Ventures, LLCaccessdata.fda.gov
November 2, 2009K092362SLEEPWEAVER NASAL CPAP MASKBZDSubstantially EquivalentCircadiance, LLCaccessdata.fda.gov
August 2, 2006K061256SMARTMONITOR 2PSNPFSubstantially EquivalentRespironics, Inc.accessdata.fda.gov
October 27, 2003K032403SMARTMONITOR 2 PROFESSIONAL SERIES (PS)NPFSubstantially EquivalentRespironics, Inc.accessdata.fda.gov
January 11, 2002K011597SMARTMONITOR 2, MODEL 4000FLSSubstantially EquivalentRespironics Georgia, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 1, 201777176Class IITerminatedSmartMonitor 2 PS/PSL, Monitor, Apnea, Facility USE. Intended for use in the continuous monitoring of respiration, heart rate, and SP02 of infant, pediatric and adult patients.Circadiance has determined that it is possible for certain Smart Monitor 2PS/PSL monitors to exhibit intermittent operation of the nurse call feature. The firm has updated the device to increase the "Nurse Call" feature to ensure monitor alarms are transmitted to compatible nurse call systems.accessdata.fda.gov

Compare with other makers

Updated March 15, 2017. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.