Skip to the page

Data / Medical devices / United States / Chembio Diagnostic Systems, Inc.

Chembio Diagnostic Systems, Inc.: FDA-registered device maker in Medford, NY, United States, 4 510(k) clearances

Chembio Diagnostic Systems, Inc. is registered with the FDA (registration 2431980) in Medford, NY, United States. It lists 18 device types. The FDA files 4 510(k) clearances under its listings, the newest dated September 29, 2023. 3 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2431980
Address
3661 Horseblock RD., Medford, NY, United States, 11763
Owner or operator
CHEMBIO DIAGNOSTIC SYSTEMS, INC. (2431980)
Roles
Complaint file establishment, Manufacturer, Manufacturer for export
First device listed
December 3, 2007
Registered through
2027
Brand names listed
Adalimumab Assay, C-Reactive Protein, Antigen, Antiserum and Control, Chembio HIV 1/2 STAT PAK Assay, DPP Ebola Antigen System, DPP HIV, DPP HIV 1/2 Assay, DPP HIV-Syphilis, DPP Zika IgM System, DPP Zika IgM System Control Pack, and DPP Micro Reader and more

Devices it lists

DeviceProduct codeClassRoleSource
Adalimumab AssayQYD2Complaint file establishment, Manufactureraccessdata.fda.gov
Antigens, Nontreponemal, AllGMQ2Manufacturer for exportaccessdata.fda.gov
Assayed Quality Control Material For Clinical Microbiology AssaysQCH2Complaint file establishment, Manufactureraccessdata.fda.gov
C-Reactive Protein, Antigen, Antiserum, And ControlDCK2Complaint file establishment, Manufactureraccessdata.fda.gov
Colorimeter, Photometer, Spectrophotometer For Clinical UseJJQ1Complaint file establishment, Manufactureraccessdata.fda.gov
Coronavirus Antigen Detection Test System.QKPNManufacturer for exportaccessdata.fda.gov
Dengue Serological ReagentsOSU2Manufacturer for exportaccessdata.fda.gov
Devices Detecting Influenza A, B, And C Virus AntigensPSZ2Manufacturer for exportaccessdata.fda.gov
Enzyme Linked Immunoabsorption Assay, Treponema PallidumLIP2Manufacturer for exportaccessdata.fda.gov
Enzyme Linked Immunosorbent Assay, T. CruziMIU1Manufacturer for exportaccessdata.fda.gov
Infliximab Test SystemQXT2Complaint file establishment, Manufactureraccessdata.fda.gov
Kit, Test, Saliva, Hiv-1&2MWB3Manufacturer for exportaccessdata.fda.gov
Reagent, Coronavirus SerologicalQKONManufacturer for exportaccessdata.fda.gov
Reagents, Ebola Zaire Virus (Detected In The West Africa Outbreak In 2014) Nucleic AcidPOGNManufacturer for exportaccessdata.fda.gov
System, Nucleic Acid Amplification, Mycobacterium Tuberculosis ComplexMWA2Manufacturer for exportaccessdata.fda.gov
Test, Hiv DetectionMZF2Complaint file establishment, Manufacturer, Manufacturer for exportaccessdata.fda.gov
Test, Qualitative, Detection Of Dengue Igm And Igg AntibodiesNWYNManufacturer for exportaccessdata.fda.gov
Zika Virus Serological ReagentsQFO2Complaint file establishment, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
September 29, 2023DEN220023Procise ADLQYDUnknownProcisedx, Inc.accessdata.fda.gov
September 29, 2023DEN210056Procise IFXQXTUnknownProcisedx, Inc.accessdata.fda.gov
November 4, 2022K201256Procise CRP, ProciseDx Analyzer, ProciseDx Calibration CartridgeDCKSubstantially EquivalentProcise Diagnosticsaccessdata.fda.gov
June 3, 2020K200506DPP Zika IgM System, DPP Zika IgM System Control Pack, and DPP Micro ReaderQFOSubstantially EquivalentChembio Diagnostic Systemsaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
June 18, 202086098Class IITerminatedChembio DPP COVID-19 IgM/IgG System- Rrapid immunochromatographic test for the qualitative detection and differentiation of Immunoglobulin M (IgM) and Immunoglobulin G (IgG) antibodies to SARS-CoV-2 in fingerstick whole FDA revocation of the Emergency Use Authorization due to performance issuesaccessdata.fda.gov
December 16, 200534263Not yet classifiedTerminatedSickle-STAT Test Kit, Catalog # SC901, a qualitative test kit for the determination of the presence of hemoglobin S in human blood --- FOR IN VITRO DIAGNOSTIC USE --- FOR PROFESSIONAL USE ONLY --- Contents: 48 pre-filledFirm received one report of a false negative with the positive control. Internal testing by the firm has shown that the kit lot may result in invalid or false negative interpretations.accessdata.fda.gov
October 6, 200430288Not yet classifiedTerminatedOTC Pregnancy Tests. Name: Sure Check hCG Midstream Pregnancy Test --- Description: the Sure Check hCG Midstream Pregnancy test consists of a lateral flow membrane pad containing anti- hCG monoclonal antibody conjugated Poor sealing of pouches and degradation of products. Firm received an from a distributor of an increase in complaints. In response to the complaints, the distributor conducted its own functional testing and noticed a degradation in performance of the two lots. Chembio's investigation revealed invalid results (no control lines) and some false negatives.accessdata.fda.gov

Compare with other makers

Updated September 29, 2023. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.