Data / Medical devices / United States / Champion MFG, INC.
Champion MFG, INC.: FDA-registered device maker in Ocala, FL, United States, 2 510(k) clearances
Champion MFG, INC. is registered with the FDA (registration 1027229) in Ocala, FL, United States. It lists 7 device types. The FDA files 2 510(k) clearances under its listings, the newest dated April 11, 2016. 9 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1027229
- Address
- 5516 SW 1st Ln, Ocala, FL, United States, 34474
- Owner or operator
- Champion Mfg, Inc. (10055089)
- Roles
- Manufacturer
- First device listed
- June 5, 2017
- Registered through
- 2026
- Brand names listed
- 54 Series, 56 Series, 58 Series, 59 Series, 85 Series, 86 Series, 89 Series, Ascent (65 Series), Ascent II (67 Series),, 54P Series, 56P Series, 58P Series, 59P Series, 85P Series, 86P Series, 89P Series, Ascent (65P Series), Alo Straight Back (61 Series), Alo Straight Back (61P Series), Alo Wing Back (63 Series), Alo Wing Back (63P Series), Alo XL Straight Back (62 Series), Alo XL Straight Back (62P series) and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Chair And Table, Medical | KMN | 1 | Manufacturer | accessdata.fda.gov |
| Chair, Adjustable, Mechanical | INN | 1 | Manufacturer | accessdata.fda.gov |
| Chair, Blood Donor | FML | 1 | Manufacturer | accessdata.fda.gov |
| Chair, Geriatric | FRJ | 1 | Manufacturer | accessdata.fda.gov |
| Chair, Surgical, Ac-Powered | GBB | 1 | Manufacturer | accessdata.fda.gov |
| Device, Transfer, Patient, Manual | FMR | 1 | Manufacturer | accessdata.fda.gov |
| Stretcher, Wheeled, Powered | INK | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| April 11, 2016 | K152056 | Winco Model S550 Stretchair | INK | Substantially Equivalent | Winco Manufacturing, LLC | accessdata.fda.gov |
| April 22, 2011 | K110671 | WINCO STRETCHAIR | INK | Substantially Equivalent | Winco Mfg., LLC | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| June 29, 2016 | 74922 | Class II | Terminated | TransMotion Medical, TMM3 Series Video-Fluoroscopy Swallow Study Stretcher-Chair. Intended use is to provide the caregiver a single platform for receiving, transporting within a facility, performing procedures, recovery | Non-conforming component caused arms of TMM4 Stretcher chair to no longer meet design specifications. | accessdata.fda.gov |
| April 2, 2015 | 71496 | Class II | Terminated | Winco XL Convalescent Recliner - with Steel Casters Long term patient recliner (Nursing, Rehabilitation, Geriatric Home Use, Retirement facilities) | Shipment of foam for chairs was received classified as Fire Retardant but was in fact standard foam and would not meet Fire Retardant standards. | accessdata.fda.gov |
| November 14, 2014 | 69671 | Class II | Terminated | Powered stretcher chair used during facial and eye surgeries. One chair per package. | The firm is finding that the stretcher chair controllers are moving the chairs involuntarily. | accessdata.fda.gov |
| September 6, 2013 | 67377 | Class II | Terminated | PREMIER CARE RECLINER 5570 with Urethane armrests, Multiple side-table options, 3 position lock-bar, Fully upholstered, OPTIONAL Heat or Heat & Massage, OPTIONAL LiquiCell. The products are a multi position recliners wit | A supplier manufacturing assembly defect with the right hand recline mechanism. Use of this product may result in the loss of functionality of the three (3) position lock bar when in a reclined position. | accessdata.fda.gov |
| September 24, 2012 | 63651 | Class II | Terminated | PREMIER LIFECARE RECLINER 5400 WITH CAL TB 133 UPGRADE PURCHASED JAN 01, 2011 TO AUGUST 20, 2012 A multi position recliner with a steel frame used primarily in clinics, hospitals, and treatment centers for recovery, dial | The performance of the chemicals in the foam and vinyl are not consistent enough to meet the TB 133 fire protection mandate required by California and 4 other states. | accessdata.fda.gov |
| July 10, 2012 | 63085 | Class II | Terminated | Caremor Cliner"***Manufactured By Winco***Ocala, FL 34474 www.wincomfg.com***Model No. 536 Serial No. 536A-101475***" Literature: "***Caremor Cliner 5351/5361***Winco***ISO 9001-2008 Certified***Our most comfortable and | Winco Mfg., LLC in Ocala, FL is recalling the Caremor Cliner model numbers 5351 and 5361. The recall was initiated due to a report that a back frame did not "snap" onto a chair frame properly. | accessdata.fda.gov |
| February 6, 2012 | 61457 | Not yet classified | Terminated | CARE CLINER 6530 (STD)/6540 (X-LG) products are labeled in part: "***CARE CLINER 6530/6540 (w/NYLON CASTERS)***Winco***ISO 9001-2008 Certified***Outstanding Value and Quality in Our Standard Care Cliner***Lower price doe | Winco Manufacturing LLC is recalling the Care Cliner, XL Care Cliner, Drop Arm Care Cliner, Elite Care Cliner, and XL Elite Care Cliner chairs with nylon casters distributed between 04/01/2009 and 08/31/2009. Certain 5" nylon casters shipped with the chairs may be defective. There is a potential of the caster's axle working itself out of the assembly under u | accessdata.fda.gov |
| October 17, 2011 | 61049 | Not yet classified | Terminated | Premier LifeCare Recliner 5400. Brochure is labeled in part: "***Premier LifeCare Recliner 5400***Winco***ISO 9001 2008 Certified***Key Features***Urethane armrests***Fully upholstered***Multiple side-table Options***3-p | On 10/17/2011 Winco Mfg. LLC, Ocala, FL initiated a recall of The Premier LifeCare Recliner and Premier Care Recliner Models 5400 and 5570 distributed between January 4, 2011 and October 12, 2011. The Position Lock Pin(s) could potentially fail if exposed to excessive force when the chair is in the Locked Recline position. This failure will result in an inop | accessdata.fda.gov |
| September 7, 2010 | 56844 | Not yet classified | Terminated | Recalled chairs include the following: 2008 Model Numbers: 653N - Care Cliner, 654N - XL Care Cliner, 655N - Drop Arm Care Cliner, 657N - XL Drop Arm Care Cliner, 690N - Elite Care Cliner, 691N - XL Elite Care Cliner, 69 | Winco Mfg., LLC, Ocala, Florida is recalling their Care Cliner. Due to malfunctioning axles which become lose from the caster assembly. This chair is a multi position recliner with a steel frame used primarily in clinics, hospitals and treatment centers for recovery, dialysis, oncology, examination, infusion. Recalled chairs include the following: Care Cline | accessdata.fda.gov |
Compare with other makers
- All makers of Stretcher, Wheeled, Powered
- All makers of Chair And Table, Medical
- All makers of Chair, Adjustable, Mechanical
- All makers of Chair, Surgical, Ac-Powered
- All makers of Chair, Geriatric
- All makers of Device, Transfer, Patient, Manual
Updated April 11, 2016. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.