Data / Medical devices / Taiwan / Carilex Medical, Inc.
Carilex Medical, Inc.: FDA-registered device maker in Guishan District Taoyuan, Taiwan, 5 510(k) clearances
Carilex Medical, Inc. is registered with the FDA (registration 9710603) in Guishan District Taoyuan, Taiwan. It lists 12 device types. The FDA files 5 510(k) clearances under its listings, the newest dated April 17, 2024. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 9710603
- FEI number
- 3003513125
- Address
- No. 77, Keji 1st Rd., Guishan District Taoyuan, Taiwan, 333
- Owner or operator
- Carilex Medical, Inc. (9048086)
- Roles
- Contract manufacturer, Exporter to the US, Foreign private label distributor, Manufacturer
- First device listed
- October 11, 2001
- Registered through
- 2026
- Brand names listed
- AVA Cure, AVA LAL, AVACare 2, Airrapy Blower, Bairrapy Mattress, Cari Chair, Centrius, Dual and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Bed, Flotation Therapy, Powered | IOQ | 2 | Manufacturer | accessdata.fda.gov |
| Bed, Patient Rotation, Powered | IKZ | 2 | Manufacturer | accessdata.fda.gov |
| Bed, Therapeutic, Ac-Powered, Adjustable Home-Use | LLI | 2 | Manufacturer | accessdata.fda.gov |
| Bottle, Collection, Vacuum | KDQ | 2 | Manufacturer | accessdata.fda.gov |
| Cushion, Flotation | KIC | 1 | Manufacturer | accessdata.fda.gov |
| Device, Patient Transfer, Powered | FRZ | 2 | Contract manufacturer | accessdata.fda.gov |
| Device, Transfer, Patient, Manual | FMR | 1 | Contract manufacturer | accessdata.fda.gov |
| Dressing, Wound, Occlusive | NAD | 1 | Exporter to the US | accessdata.fda.gov |
| Lift, Patient, Ac-Powered | FNG | 2 | Contract manufacturer | accessdata.fda.gov |
| Mattress, Air Flotation, Alternating Pressure | FNM | 2 | Manufacturer | accessdata.fda.gov |
| Mattress, Flotation Therapy, Non-Powered | IKY | 1 | Manufacturer | accessdata.fda.gov |
| Negative Pressure Wound Therapy Powered Suction Pump | OMP | 2 | Exporter to the US, Foreign private label distributor, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| April 17, 2024 | K231646 | Carilex VT¿200-i NX | OMP | Substantially Equivalent | Carilex Medical, Inc. | accessdata.fda.gov |
| December 15, 2021 | K202823 | Innomed NPWT Silicone Foam Dressing | OMP | Substantially Equivalent | Zhejiang Longterm Medical Technology Co., Ltd. | accessdata.fda.gov |
| August 9, 2018 | K173407 | VT - 100, VT - 200 | OMP | Substantially Equivalent | Carilex Medical, Inc. | accessdata.fda.gov |
| June 8, 2018 | K172725 | VT Dressing Kits | OMP | Substantially Equivalent | Carilex Medical, Inc. | accessdata.fda.gov |
| October 13, 2016 | K161410 | VT·One, VT·One 60days | OMP | Substantially Equivalent | Carilex Medical, Inc. | accessdata.fda.gov |
Compare with other makers
- All makers of Bed, Flotation Therapy, Powered
- All makers of Bed, Therapeutic, Ac-Powered, Adjustable Home-Use
- All makers of Negative Pressure Wound Therapy Powered Suction Pump
- All makers of Lift, Patient, Ac-Powered
- All makers of Device, Patient Transfer, Powered
- All makers of Bottle, Collection, Vacuum
Updated April 17, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.