Skip to the page

Data / Medical devices / United States / CareFusion 303, INC

CareFusion 303, INC: FDA-registered device maker in San Diego, CA, United States, 6 510(k) clearances

CareFusion 303, INC is registered with the FDA (registration 3003879246) in San Diego, CA, United States. It lists 6 device types. The FDA files 6 510(k) clearances under its listings, the newest dated April 25, 2025. 12 recall events name it as the recalling firm (1 Class I). Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3003879246
Address
3750 Torrey View Ct, San Diego, CA, United States, 92130
Owner or operator
CareFusion 303, INC. (9068764)
Roles
Complaint file establishment, Manufacturer, Specification developer
First device listed
September 10, 2007
Registered through
2027
Brand names listed
Alaris PC Unit, Alaris PCA, Alaris/Medley EtCO2 Module, Alaris/Medley SpO2 Module, Alaris™ Auto-ID Module, Alaris™ Guardrails™ Editor Software, Alaris™ PCA Module, Model 8120, Alaris™ PCA Module, Model 8120, Software and more

Devices it lists

DeviceProduct codeClassRoleSource
Analyzer, Gas, Carbon-Dioxide, Gaseous-PhaseCCK2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Cabinet, Table And Tray, AnesthesiaBRY1Complaint file establishment, Specification developeraccessdata.fda.gov
Infusion Safety Management SoftwarePHC2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
OximeterDQA2Complaint file establishment, Specification developeraccessdata.fda.gov
Pump, InfusionFRN2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Pump, Infusion, PcaMEA2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 25, 2025K243855BD Alaris Infusion System with Guardrails Suite MXFRNSubstantially EquivalentCarefusion 303, Inc.accessdata.fda.gov
July 21, 2023K211218BD Alaris System with Guardrails Suite MX v12.1.2FRNSubstantially EquivalentCarefusion 303, Inc.accessdata.fda.gov
October 20, 2005K051641ALARIS SYSTEM PC UNIT, MODEL 8001FRNSubstantially EquivalentCardinal Health, Alaris Productsaccessdata.fda.gov
December 10, 2004K043299MEDLEY PCA MODULE, MODEL 8120MEASubstantially EquivalentAlaris Medical Systems, Inc.accessdata.fda.gov
February 9, 2004K031741MEDLEY ETCO2 MODULE (INCLUDES ACCESSORIES), MODEL 8300CCKSubstantially EquivalentAlaris Medical Systems, Inc.accessdata.fda.gov
June 8, 2001K010966MEDLEY SP02 MODULE, MODEL 8220DQASubstantially EquivalentAlaris Medical Systems, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
March 6, 201364728Class ITerminatedAlaris PC unit model 8015 with software version 9.12 Product Usage: The Alaris PC unit is the central programming, monitoring and power supply component for the Alaris System.The recall was initiated because Carefusion has received reports of a communication error on the Alaris PC unit model 8015 with software version 9.12 when the Alaris EtCO2 module or Alaris SpO2 module is attached.accessdata.fda.gov
March 6, 201364653Class IITerminatedAlaris PC unit model 8015 with software version 9.12 Product Usage: The Alaris PC unit is the central programming, monitoring and power supply component for the Alaris SystemThe recall was initiated because Carefusion has identified potential risk associated with bolus programming with the Alaris PC unit (model 8015) software version 9.12. Automating infusion pump parameter input from either the electronic medical record (EMR) or the Alaris Auto-ID module for a continuous infusion with a bolus dose option may result in a loss ofaccessdata.fda.gov
December 20, 201264204Class IITerminatedCareFusion SmartSite Gravity Blood Set Model 42082E. Used to administer blood and blood products through a needle or catheter inserted into the patient's artery or vein.CareFusion is recalling the SmartSite Gravity Blood Set as a result of a potential for separation at the connection of the drip chamber and tubing. The separation may be observed at priming or observed during use. If a separation between the drip chamber and tubing occurs, this could cause a delay in treatment.accessdata.fda.gov
December 24, 200852767Not yet classifiedTerminatedPyxis Anesthesia System 3500, Cardinal Health, Clinical Technologies and Services, San Diego, CA. The Pyxis Anesthesia Station 3500 is a medication dispensing product that provides medication and inventory management forCardinal Health has sent out a Safety Alert Notification to inform its customers that the SR2b Software for the Pyxis Anesthesia System 3500 (PAS 3500) has received several customer reports of system "non-responsiveness" (lock ups) during the use of the product since its release in September 2008.accessdata.fda.gov
March 5, 200847335Not yet classifiedTerminatedU19 Socketed Integrated Circuit ("U19 IC") on the logic board of Alaris Pump modules (aka. Medley Pump modules), Model 8100 built on or before September 8, 2005. CardinalHealth, San Diego, CA 92130A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failures of the U19 Socketed Integrated Circuits (U19 IC) on the logic board of the Alaris Pump module ("Pump module"). The user will be required to replace the affected module.accessdata.fda.gov
October 29, 200745504Not yet classifiedTerminatedCardinal Health Alaris Pump Module (formerly Medley Pump Module), Model 8100, Cardinal Health, San Diego, CA. (All Alaris Pump modules shipped prior to December 23, 2007 are subject to this recall)Inaccurate flow rate; related to misassembled (missing, bent or broken) springs during the manufacturing or servicing of the mechanism assemblyaccessdata.fda.gov
August 30, 200744826Not yet classifiedTerminatedTexium Closed Male Luer (CML), Model Number 10012241, Cardinal Health, SanDiego, CA.Leaks: there is a risk of leakage at the female end of the Texium closed male luer (CML) when attached to a spin luer. (NOTE: users who connect the female portion of the Texium closed male luer to fixed (one-piece) male luers on tubing or on syringes are not affected by this issue)accessdata.fda.gov
August 13, 200739378Not yet classifiedTerminatedPyxis Anesthesia System 3500, Cardinal Health, Clinical Technologies and Services, San Diego, CASystem lock up; mini-drawers -under certain circumstances during use, are not accessable, delaying the user from accessing critical medications.accessdata.fda.gov
June 18, 200738225Not yet classifiedTerminatedAll IV Administration Infusion Sets intended for use with the Gemini Infusion Pump and Alaris Pump module (a.k.a. Medley Pump module) including: Alaris SmartSite Low Sorbing Set, Alaris Vented Syringe Adapter Set, AlarisIt has been determined that with low probability, over-infusion may occur as a result of an open safety clamp fitment (a.k.a. Flo-Stop fitment) on the pumping segment, whether opened intentionally in the course of expected clinical practice, or as a result of inadvertent action. The over-infusion occurrence is dependent on the user not closing the roller claaccessdata.fda.gov
June 5, 200738215Not yet classifiedTerminatedAlaris Medical Systems IV Administration Set, Low Sorbing Extension Set, Model C20014, Rx Only, Alaris Medical Systems, Lot Number 07036013The sterility of the product may be compromised as the packaging used for the sterility barrier was not designed for the sterility process used by the firm.accessdata.fda.gov
August 10, 200636064Not yet classifiedTerminatedAlaris SE Pump (formerly Signature Edition Infusion Pump); Model Numbers: 7000, 7100, 7101, 7130, 7131, 7132, 7200, 7201, 7230, 7231, and 7232This recall was initiated because of a potential for over infusion with all models of the Alaris SE Pumps (formerly the Signature Edition Infusion Pumps) caused by key bounce.accessdata.fda.gov
November 10, 200430451Not yet classifiedTerminatedModel 8100 Series Medley Medication Safety System Pump ModuleThe device modification is being implemented in response to information received from the field regarding a specific method of misloading the medication administration tubing set into the infusion system pump module. To date there have been complaints from three (3) different customer locations.accessdata.fda.gov

Compare with other makers

Updated April 25, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.