Skip to the page

Data / Medical devices / United States / Brasseler U.S.A. Medical, LLC

Brasseler U.S.A. Medical, LLC: FDA-registered device maker in Savannah, GA, United States, 11 510(k) clearances

Brasseler U.S.A. Medical, LLC is registered with the FDA (registration 2025102) in Savannah, GA, United States. It lists 16 device types. The FDA files 11 510(k) clearances under its listings, the newest dated April 3, 2003. 3 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2025102
FEI number
3004949275
Address
1 Brasseler Blvd, Savannah, GA, United States, 31419
Owner or operator
Brasseler U.S.A. Medical, LLC (9010748)
Roles
Contract manufacturer, Manufacturer, Repackager or relabeler, Specification developer
First device listed
June 21, 1994
Registered through
2026
Brand names listed
Arthrex Large Bone Sagittal Blade, Axiom Slap Hammer, BRASSELER BLADE, SAW, SURGICAL CARDIOVASCULAR, BRASSELER BUR, SURGICAL, GENERAL & PLASTIC SURGERY SURGICAL, BRASSELER BURR, ORTHOPEDIC, BRASSELER DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED), BRASSELER Instrument, surgical, orthopedic, pneumatic powered & accessory/attachment, BRASSELER LAVAGE JET and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 3, 2003K030172SMALL HIGH SPEED MOTOR DRILL SYSTEMHBESubstantially EquivalentBrasseler USA I, L.P.accessdata.fda.gov
January 14, 1999K983223DENTAL STERLIZATION TRAY/CASSETTEFRGSubstantially EquivalentBrasseler USA I, L.P.accessdata.fda.gov
June 20, 1997K970916H.V. PULSE LAVAGE (L31 SERIES)FQHSubstantially EquivalentGlobal Medical Products, Inc.accessdata.fda.gov
March 7, 1995K945670KIRSCHNER (K-WIRE), STEINMAN PINSJDWSubstantially EquivalentBrasseler USA I, L.P.accessdata.fda.gov
August 22, 1994K943758SURGICAL BURGFFSubstantially EquivalentKomet Medicalaccessdata.fda.gov
April 21, 1994K935367TAVA WIRE-DRIVERHSZSubstantially EquivalentTava Surgical Instrumentsaccessdata.fda.gov
February 22, 1994K940109TAVA K-WIREHTYSubstantially EquivalentTava Surgical Instrumentsaccessdata.fda.gov
September 15, 1988K883255KOMET SURGICAL BURGFFSubstantially EquivalentKomet Medical, Div. of Brasseler USA I, L.P.accessdata.fda.gov
July 2, 1987K872475SURGICAL BURGFFSubstantially EquivalentTava Surgical Instrumentsaccessdata.fda.gov
October 14, 1986K863788SAWBLADEGFASubstantially EquivalentTava Surgical Instrumentsaccessdata.fda.gov
January 27, 1986K854543PULSE LAVAGEFQHSubstantially EquivalentTava Surgical Instrumentsaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
January 28, 202289555Class IITerminatedBrasseler USA, K-WIRE, Double Trocar Smooth, REF KM172-26-35SOne lot of product was distributed in unsealed packagingaccessdata.fda.gov
December 11, 201984545Class IITerminatedBrasseler USA KM169-39-76 Steinmann Pin Single Diamond Smooth, Diameter 2.8 mm, Length 228 mm Product Usage: A Steinmann Pin is used for internal fixation of large bone fractures.103 packaged and labeled tubes (103 product tubes with 6 pins per tube) of KM168-39-76 Single Diamond Smooth Steinmann Pins were labeled with the incorrect product labels. The tubes were incorrectly labeled as KM169-39-76 Single Diamond Threaded Steinmann Pins.accessdata.fda.gov
October 18, 201984177Class IITerminatedBRASSELER KM166-310-35 Twist Drill Quick Connect Diameter 3.5 mm, Total Length 112mm, Effective Length, 86mm - Product Usage: Twist drill intended use: to drill into bone in hip or knee surgeries.One lot of 3.5 mm twist drills were incorrectly laser etched as 2.5 mm the shaft of the device.accessdata.fda.gov

Compare with other makers

Updated April 3, 2003. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.