Skip to the page

Data / Medical devices / Germany / Brainlab Se

Brainlab Se: FDA-registered device maker in Munich Bavaria, Germany, 75 510(k) clearances

Brainlab Se is registered with the FDA (registration 8043933) in Munich Bavaria, Germany. It lists 38 device types. The FDA files 75 510(k) clearances under its listings, the newest dated October 5, 2026. 40 recall events name it as the recalling firm (2 Class I). Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
8043933
FEI number
3002619595
Address
Olof-Palme-Strasse 9, Munich Bavaria, Germany, 81829
Owner or operator
Brainlab SE (9004547)
Roles
Exporter to the US, Manufacturer
First device listed
April 23, 2007
Registered through
2027
Brand names listed
(Elements) Cranial SRS w/ Cones, (Elements) Cranial SRS; (Elements) Spine SRS, (Elements) Dose Review, (Elements) Multiple Brain Mets SRS, (Elements) RT Planning Platform, (Elements) Retreatment Review, 27 Display Drape, 27 Touchdisplay Foreseeson and more

Devices it lists

DeviceProduct codeClassRoleSource
Accelerator, Linear, MedicalIYE2Exporter to the US, Manufactureraccessdata.fda.gov
Automated Radiological Image Processing SoftwareQIH2Manufactureraccessdata.fda.gov
Brain Stimulation Programming Planning Software.QQC2Manufactureraccessdata.fda.gov
Camera, Surgical And AccessoriesKQM1Exporter to the USaccessdata.fda.gov
Cart, Emergency, Cardiopulmonary (Excluding Equipment)BZN1Exporter to the USaccessdata.fda.gov
Catheter, VentricularHCA2Manufactureraccessdata.fda.gov
Display, Cathode-Ray Tube, MedicalDXJ2Exporter to the USaccessdata.fda.gov
Drape, Surgical, ExemptPUI2Exporter to the US, Manufactureraccessdata.fda.gov
Drills, Burrs, Trephines & Accessories (Simple, Powered)HBE2Manufactureraccessdata.fda.gov
Ear, Nose, And Throat Stereotaxic InstrumentPGW2Manufactureraccessdata.fda.gov
Electromyograph, DiagnosticIKN2Exporter to the USaccessdata.fda.gov
Headrest, NeurosurgicalHBM1Exporter to the USaccessdata.fda.gov
Holder, Head, Neurosurgical (Skull Clamp)HBL2Manufactureraccessdata.fda.gov
Interventional Fluoroscopic X-Ray SystemOWB2Exporter to the US, Manufactureraccessdata.fda.gov
Lens, Spectacle, Non-Custom (Prescription)HQG1Exporter to the USaccessdata.fda.gov
Medical Device Data SystemOUG1Exporter to the US, Manufactureraccessdata.fda.gov
Neurological Stereotaxic InstrumentHAW2Exporter to the US, Manufactureraccessdata.fda.gov
Orthopedic Augmented RealitySBF2Manufactureraccessdata.fda.gov
Orthopedic Stereotaxic InstrumentOLO2Manufactureraccessdata.fda.gov
Phantom, Anthropomorphic, RadiographicIXG1Exporter to the USaccessdata.fda.gov
Radiological Image Processing Software For Radiation TherapyQKB2Exporter to the USaccessdata.fda.gov
ScrewdriverHXX1Manufactureraccessdata.fda.gov
Screwdriver, SkullplateGXL1Manufactureraccessdata.fda.gov
Stand, InfusionFOX1Exporter to the USaccessdata.fda.gov
Stimulator, Electrical, Evoked ResponseGWF2Exporter to the USaccessdata.fda.gov
System, Digital Image Communications, RadiologicalLMD1Manufactureraccessdata.fda.gov
System, Image Processing, RadiologicalLLZ2Exporter to the US, Manufactureraccessdata.fda.gov
System, Imaging, Pulsed Doppler, UltrasonicIYN2Exporter to the USaccessdata.fda.gov
System, Imaging, Pulsed Echo, UltrasonicIYO2Exporter to the USaccessdata.fda.gov
System, Planning, Radiation Therapy TreatmentMUJ2Exporter to the US, Manufactureraccessdata.fda.gov
System, Radiation Therapy, Charged-Particle, MedicalLHN2Manufactureraccessdata.fda.gov
System, X-Ray, Film Marking, RadiographicJAC1Exporter to the US, Manufactureraccessdata.fda.gov
System, X-Ray, Tomography, ComputedJAK2Exporter to the US, Manufactureraccessdata.fda.gov
Table, Radiographic, Stationary TopIXQ2Exporter to the USaccessdata.fda.gov
Table, Surgical With Orthopedic Accessories, Ac-PoweredJEA1Exporter to the USaccessdata.fda.gov
Transducer, Ultrasonic, DiagnosticITX2Exporter to the USaccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Manufactureraccessdata.fda.gov
WrenchHXC1Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
October 5, 2026K261655RT Elements (4.6)MUJSubstantially EquivalentBrainlab SEaccessdata.fda.gov
September 30, 2026K262257Spine Planning (3.0); Spine & Trauma Navigation; Alignment System SpineOLOSubstantially EquivalentBrainlab SEaccessdata.fda.gov
January 14, 2026K254010ExacTrac Dynamic (2.0.2); ExacTrac Dynamic SurfaceIYESubstantially EquivalentBrainlab SEaccessdata.fda.gov
October 16, 2025K252476Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart LayoutLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
September 12, 2025K252562Spine & Trauma Navigation InstrumentsOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 22, 2025K243432Vascular Navigation PAD 2.0; Navigation Software Vascular PADOWBSubstantially EquivalentBrainlab AGaccessdata.fda.gov
June 23, 2025K243142Cranial 4Pi ImmobilizationIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
June 17, 2025K250440RT Elements (4.5); (Elements) Multiple Brain Mets SRS; (Elements) Cranial SRS; (Elements) Spine SRS; (Elements) Cranial SRS w/ Cones; (Elements) RT Planning Platform; (Elements) Dose Review; (Elements) Retreatment Review; Elements Segmentation [Cranial , Basal Ganglia, Head & Neck, Pelvic, Spine, Thoracic & Spine, Extracranial] RT; Elements AI Tumor Segmentation RT; Elements SmartBrush [Angio, Spine] RT; Elements Object Management RTMUJSubstantially EquivalentBrainlab AGaccessdata.fda.gov
June 13, 2025K243633Brainlab Elements (7.0); Brainlab Elements Image Fusion (5.0); Brainlab Elements Image Fusion Angio (1.0); Brainlab Elements Contouring (5.0); Brainlab Elements Fibertracking (3.0); Brainlab Elements BOLD MRI Mapping (1.0)QIHSubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 16, 2025K242569Mixed Reality Spine NavigationSBFSubstantially EquivalentBrainlab AGaccessdata.fda.gov
March 28, 2025K234067ImagingRing m (Version 2.0); Loop-X (Version 2.0); Loop-X Mobile Imaging Robot (Version 2.0)OWBSubstantially EquivalentMedphoton GmbHaccessdata.fda.gov
January 28, 2025K243698Alignment System Cranial, with Alignment Software Cranial with LITT; Cirq Alignment Software Cranial Biopsy; Cirq Alignment Software Cranial sEEG; VarioGuide Alignment Software Cranial; Cirq Alignment Software Cranial LITTHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 24, 2024K240431ExacTrac Dynamic (2.0); ExacTrac Dynamic SurfaceIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 23, 2024K240701Drill Guide; Drill Bit; Spine & Trauma NavigationOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 21, 2024K232759Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart LayoutLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 22, 2024K234068ART-Plan (v.2.2.0)MUJSubstantially EquivalentTherapanacea Sasaccessdata.fda.gov
March 20, 2024K234047Automatic RegistrationOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
December 22, 2023K232479ART-PlanMUJSubstantially EquivalentTherapanaceaaccessdata.fda.gov
November 20, 2023K231498TraumaCad NeoLLZSubstantially EquivalentBrainlab , Ltd.accessdata.fda.gov
September 9, 2023K223864Alignment System Cranial, Alignment Software Cranial, Cirq Alignment Software Cranial Biopsy, Cirq Alignment Software Cranial sEEG, Varioguide Alignment Software CranialHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
August 2, 2023K223553Spine Planning (2.0), Elements Spine Planning, Elements Planning SpineOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 21, 2023K223288Cranial Navigation, Navigation Software Cranial, Navigation Software Craniofacial, Cranial EM System, Automatic Registration iMRIHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 14, 2023K223106Brainlab Elements Image Fusion, Contouring (4.5);Image Fusion (4.5);Fibertracking (2.0);BOLD MRI Mapping (1.0);Image Fusion Angio (1.0)QIHSubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 11, 2023K231052ExacTrac Dynamic 1.1.2IYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 27, 2023K223734ENT EMPGWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 19, 2023K230023ART-PlanQKBSubstantially EquivalentTherapanacea Sasaccessdata.fda.gov
April 19, 2023K223552Brainlab Elements – Trajectory Planning (2.6), Elements Stereotaxy, Elements Lead Localization, Elements Trajectory Planning CranialHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
March 14, 2023K223279RT Elements (4.0)MUJSubstantially EquivalentBrainlab AGaccessdata.fda.gov
February 22, 2023K230201Disposable Pre-calibrated Brain Biopsy Needle 2.0HAWSubstantially EquivalentPAJUNK GmbH Medizintechnologieaccessdata.fda.gov
October 27, 2022K222966Cirq Arm System (2.0);Alignment System SpineOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
September 8, 2022K213989Cranial EM SystemHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
August 30, 2022K221618Spine & Trauma Navigation, Spine Navigation, Navigation Software Spine & Trauma, Alignment System Spine, Alignment Software Spine, Cirq Arm SystemOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 29, 2022K220338ExacTrac DynamicIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 19, 2022K213930Brainlab Elements Guide XT, Guide 3.0QQCSubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 13, 2022K212245Spine and Trauma Navigation System, Spine & Trauma 3D Navigation, Instrument Selection, Fluoro 3D, Registration Software Fluoro 3D, Registration Software Paired Point, Registration Software Spine Surface Matching, Spine Planning, Elements Screw Planning Spine, Elements Spine Screw PlanningOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
December 16, 2021K212420Brainlab Elements, Brainlab Elements Contouring, Brainlab Elements Fibertracking, Brainlab Elements Image Fusion, Brainlab Elements Image Fusion AngioLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
November 12, 2021K210989Cirq, Cirq Robotic Alignment System, Cirq Robotic Alignment Module Cranial, Cirq Robotic Alignment Module, Cirq Robotic Alignment Cranial And Spine, CIRQ Robotic Alignment Cranial and Spine SystemHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
November 3, 2021K211544Trajectory Planning, Elements Trajectory Planning, Elements Lead LocalizationHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 22, 2021K211939ExacTrac DynamicIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 9, 2021K203681RT Elements, Cranial SRS w/ Cones, Multiple Brain Mets SRS, Cranial SRS, Spine SRS, RT QA, Dose ReviewMUJSubstantially EquivalentBrainlab AGaccessdata.fda.gov
March 18, 2021K203679Automatic RegistrationOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
January 29, 2021K201752Disposable Pre-calibrated SuctionHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
December 23, 2020K202320CIRQ Robotic Alignment Module, Cirq, Cirq Robotic Alignment Module Spinal, Cirq Robotic Alignment Cranial and Spine, CIRQ Robotic Alignment Cranial and Spine SystemOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
December 22, 2020K203281Mobile ImagingRing System, IRm, Loop-X Mobile Imaging Robot, Loop-XOWBSubstantially EquivalentMedphoton GmbHaccessdata.fda.gov
November 12, 2020K203173ExacTrac DynamicIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
October 8, 2020K192703Cranial Image Guided Surgery System, Navigation Software Cranial, Navigation Software ENT, Registration Software Cranial, Automatic Registration 2.0, Ultrasound Navigation Software (BK), Intraoperative Structure UpdateHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
August 19, 2020K202050Cranial 4Pi ImmobilizationIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
January 23, 2020K191014Elements ViewerLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
September 6, 2019K190250Microscope NavigationHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
August 29, 2019K183605Spine & Trauma NavigationOLOSubstantially EquivalentBrainlab AGaccessdata.fda.gov
August 1, 2019K190887Leksell Vantage Stereotactic SystemHAWSubstantially EquivalentElekta Instrument ABaccessdata.fda.gov
April 25, 2019K190042Brainlab Elements Image Fusion AngioLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
March 15, 2018K180393AIRO Computed Tomography (CT) X-ray SystemJAKSubstantially EquivalentMobius Imaging, LLCaccessdata.fda.gov
February 22, 2018K173381Nexxis ORDXJSubstantially EquivalentBarco N.V.accessdata.fda.gov
September 26, 2017K170816Elements Image Fusion, Elements Cranial Distortion Correction, Elements Spine Curvature Correction, Elements TRAMLLZSubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 30, 2017K163505ARIETTA PRECISIONIYNSubstantially EquivalentHitachi , Ltd.accessdata.fda.gov
April 13, 2015K142647mint LesionLLZSubstantially EquivalentMint Medical GmbHaccessdata.fda.gov
March 20, 2014K132436VARIOGUIDE DRILL KITHBESubstantially EquivalentMri Interventions, Inc.accessdata.fda.gov
September 26, 2013K131431AIRO CT SYSTEMJAKSubstantially EquivalentMobius Imaging, LLCaccessdata.fda.gov
August 16, 2013K123605SMARTFLOW CATHETERHCASubstantially EquivalentMri Interventions, Inc.accessdata.fda.gov
April 26, 2013K122225STERILE RADIOLUCENT SKULL PINSHBLSubstantially EquivalentBrainlab AGaccessdata.fda.gov
April 22, 2013K122167NEXXIS ORDXJSubstantially EquivalentBarco N.V.accessdata.fda.gov
January 15, 2013K123788INTEGRATED COLLIMATOR VERIFICATION AND INTERLOCK SYSTEM (ICVI)IYESubstantially EquivalentVarian Medical Systems, Inc.accessdata.fda.gov
August 14, 2012K120789EXACTRAC X-RAY X-RAYIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 22, 2012K112881NEXSTIM NAVIGATED BRAIN STIMULATION (NBS) SYSTEM 4, NEXSTIM NBS SYSTEM 4 WITH NEXSPEECH(TM)GWFSubstantially EquivalentNexstim OYaccessdata.fda.gov
May 7, 2012K113732IPLAN (IPLAN CRANIAL, IPLAN STEREOTAXY, IPLAN ENT, IPLAN CMF, IPLAN VIEW, IPLAN SPINE)JAKSubstantially EquivalentBrainlab AGaccessdata.fda.gov
July 14, 2010K100038DISPOSABLE REFLECTIVE MARKER SPHERESHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
May 6, 2010K092467VECTORVISION CRANIAL, VECTORVISION ENT, KOLIBRI CRANIAL, KOLIBRI ENT, CRANIAL ESSENTIAL, CRANIAL UNLIMITEDHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
March 19, 2008K073714TRAUMACAD VERSION 2.0LLZSubstantially EquivalentOrthocrat, Ltd.accessdata.fda.gov
July 25, 2006K060808BRAINPRO, BRAINPRO ACCESSHAWSubstantially EquivalentPAJUNK GmbH Medizintechnologieaccessdata.fda.gov
March 23, 2006K053164IPLAN FLOWHAWSubstantially EquivalentBrainlab AGaccessdata.fda.gov
February 3, 2006K053500FRAMELESS RADIOSURGERY COMPONENTSIYESubstantially EquivalentBrainlab AGaccessdata.fda.gov
January 27, 2004K033621NDI PASSIVE SPHERESHAWSubstantially EquivalentNorthern Digital, Inc.accessdata.fda.gov
March 4, 2002K014022MRI LINE MARKERIYESubstantially EquivalentI.Z.I. Corp.accessdata.fda.gov
June 5, 1995K945903BRAINLAB MASK SYSTEMIYESubstantially EquivalentBrainlab Med. Computersysteme GmbHaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
February 10, 202596241Class IIOngoingOrigin Data Management software versions 3.1.0, 3.1.1, 3.1.2, 3.2.0, 3.2.1Under certain circumstances, it can occur that patient records from unrelated individuals are automatically merged into one patient record without user notification.accessdata.fda.gov
March 2, 202391781Class IIOngoingCirq Arm System 2.0Risk of mechanical instability due to potential manufacturing error of the deviceaccessdata.fda.gov
February 14, 202391664Class IIOngoingBrainlab ExacTrac Dynamic software, Medical Charged-Particle Radiation Therapy System, model 20910-01E and 20910-01F.Deep Inspiration Breath Hold (DIBH) functionality may not work as specified when based on a standard-workflow Treatment Templateaccessdata.fda.gov
February 25, 202289662Class IIOngoingExacTrac Dynamic software model numbers: 20910-01, ETD Positioning and Moni. 1.0.0 INST; 20910-01A, ETD Positioning and Moni. 1.0.1 INST; 20910-01B, ETD Positioning and Moni. 1.0.2 INST; and 20910-01C ETD Positioning andThe yaw angle may be incorrect for CBCT positioning workflows using setup beams with Varian LINACs.accessdata.fda.gov
May 14, 202187984Class IITerminatedExacTrac Dynamic software, Model 20910-01B ETD Positioning and Monitoring Installer 1.0.2 - Product Usage: intended to position patients at an accurately defined point within the treatment beam of a medical accelerator fDisplay of potential patient movement might be delayed to the user for high dose treatments.accessdata.fda.gov
March 1, 202187395Class IITerminatedExacTrac Dynamic (Medical Charged-Particle Radiation Therapy System).In case of a failed automatic marker detection, a software error causes parts of the display to incorrectly behave as if the current patient position is within predefined tolerances and may allow the user to proceed to treatment despite potentially exceeding shift values.accessdata.fda.gov
August 31, 202086438Class IITerminatedUltrasound Navigation Software 1.0 and Ultrasound Integration Software for Cranial/ENT Navigation 3.0.x and 3.1.x - Product Usage: intended to be an intra-operative image guided localization system to enable minimally inBrainlab Ultrasound Navigation Software does not support the modification of the probe's image width.accessdata.fda.gov
August 20, 202086272Class IITerminatedCirq Arm System - Model SBS 1.3.2 (Art.No. 56000-01B) and SBS 1.4 (Art.No. 56000-01C) of the CIRQ Arm System (56000 and 56000A)Holding force of the Positioning Arm can be reduced by prolonged non-use.accessdata.fda.gov
July 16, 202086046Class IITerminatedBRAINLAB Curve; Model/catalogue (article) numbers for Curve: 19901; 19901B; 19900; 19905 UDI (GTIN) for Curve: 04056481138011Incorrect manufacturer calibrationaccessdata.fda.gov
September 25, 201983978Class IITerminatedPatient Data Manager, Model/Catalogue Numbers: 25100-09 - PATIENT DATA MANAGER 2.1.1LICENSE ONLY 25100-10 - PATIENT DATA MANAGER 2.2.0 LICENSE ONLY 25100-11 - PATIENT DATA MANAGER 2.2.1 LICENSE ONLY 25100-12 - PATIENT DAThe Brainlab Patient Data Manager software (PDM) in combination with the Brainlab iPlan CMF/Cranial/ENT/Spine software 2.1.1, 2.2.0, 2.2.1, 2.3.0, 2.3.1, 2.4.0, 2.5.0, 2.5.1 (if used in combination with iPlan CMF/Cranial/ENT/Spine 3.0.5, 3.0.6) that may lead to shifts applied to segmentation objects in iPlan being not reflected when exported into DICOM underaccessdata.fda.gov
March 11, 201982601Class IITerminatedRT Elements Software revisions of the RT Elements applications have a specific software version number. Specifically the following RT Elements applications/versions are affected: - Cranial SRS 1.0.0 and 1.5.0 - Spine SRSThere is a potential for an incorrect dose distribution calculation by Brainlab RT Elements software (for affected versions) under specific circumstances when using the Pencil Beam algorithm on the GPU (graphics card), as is the default system setting.accessdata.fda.gov
February 27, 201982304Class ITerminatedSpine & Trauma 3D Navigation 1.0 (subpart of the system Navigation Software Spine & Trauma 3D, Version 3.0 ) Intended Use The Spine & Trauma Navigation System is intended as an intraoperative image-guided localization syIn certain occurrences, the affected navigation software application might unexpectedly display a navigated instrument in an axial, coronal/sagittal (ACS) view representation with fixed planes in the image reconstruction (the not-updated ACS view ), instead of displaying the desirable view representation Inline View, which is commonly used for navigating invaccessdata.fda.gov
February 14, 201879266Class IITerminatedExacTrac versions 6.5 through 6.5 intended to be used to place patients at an accurately defined point within the treatment beam of a medical accelerator for stereotactic radiosurgery or radiotherapy procedures, in orderThe usage of workflows that deviate from the recommended specifications in the User manual for ExacTrac Patient Positioning System (versions 6.0, 6.1, 6.2, 6.5) with Auxiliary Device Interface (ADI) and Varian Clinac or Varian TrueBeam, which may result in misinterpretation of beam authorization via ADI.accessdata.fda.gov
November 16, 201778715Class IITerminatedBrainlab Navigation System Spine & Trauma 3D with component Brainlab DrapeLink Registration Kit for C-arm Zeihm Vision RFD: Adapter LeftDue to a human error at a supplier, an unknown number of devices within one specific production lot of Brainlab DrapeLink Adapters (Left/Right) were not manufactured according to defined specifications.accessdata.fda.gov
November 3, 201778488Class IITerminatedBRAINLAB EXACTRAC VERO, Model/Catalog Numbers: 46228 EXACTRAC VERO 3.5 46238 EXACTRAC VERO 3.5 46216 EXACTRAC VERO SW UPDATE 3.5.2 TO 3.5.3 46218 EXACTRAC VERO SW UPDATE 3.5.3 TO 3.5.4 The ExacTrac Vero system is intendeBrainlab has internally detected that under specific conditions ExacTrac Vero may not correctly account for this ring angle correction during the calculation of the corresponding couch shift. This may result in the treatment couch not moving to the exact planned position resulting in a deviation between the planned and the treatment target position. This devaccessdata.fda.gov
October 27, 201675548Class IITerminatedFemoral and Tibial Cutting Block Adapter Base. Brainlab knee, BrainLAB Image Guided Surgery System / Instrument, StereotaxicBrainlab Knee Navigation System: Femoral and Tibial Cutting Block Adapter Base with specific serial numbers might contain parts made from incorrect material and therefore not be suitable for reprocessingaccessdata.fda.gov
May 4, 201674265Class IITerminatedExacTrac Vero is a Patient Positioning System for Radiation therapy.Potentially incorrect positioning when using Implanted Marker Detection with Brainlab ExacTrac Vero 3.5accessdata.fda.gov
November 5, 201572804Class IITerminatedRT Elements are applications for radiation treatment planning for use in stereotactic, conformal, computer planned, Linac based radiation treatment of cranial, head and neck, and extracranial lesions. The simulated plan Large objects with fine resolution are potentially displayed cropped when imported into Brainlab Brain Metastases 1.0.0.accessdata.fda.gov
September 21, 201572236Class IITerminatedDigital Lightbox, BrainLAB system, image processing, radiological Product Usage: The Patient Data Manager is a system intended for the display of medical images. The software can transfer images to and from picture archiPotentially incorrectly displayed objects when actively deselecting a fused reference dataset.accessdata.fda.gov
August 18, 201571996Class IITerminatedDisposable Reflective Marker Spheres The Disposable Reflective Marker Spheres used in conjunction with a stereotaxic instrument consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probDisposable Reflective Marker Spheres (DRMS) for Brainlab Image Guided Surgery (IGS) Systems: DRMS spheres may separate at the mid-point where the two halves of the sphere are sealed together.accessdata.fda.gov
August 5, 201571898Class IITerminatedExacTrac 6.0.x Patient Positioning System, Radiation therapy. Intended to be used to place patients at an accurately defined point within the treatment beam of a medical accelerator for stereotactic radiosurgery or radioExacTrac 6.0 Patient Positioning System: Display of potentially incorrect Digitally Reconstructed Radiograph (DRR) for x-ray correction and verification.accessdata.fda.gov
May 8, 201571248Class IITerminatedBrainLAB Image Guided Surgery (IGS) System, Stereotaxic Instrument navigation software, Cranial ENT version 2.1, and Spine and Trauma 3D versions 2.0 and 2.1 An intraoperative image-guided localization system to enable mInstances of data sets not being accurately registered to the patient anatomy were observed.accessdata.fda.gov
March 6, 201570951Class IITerminatedExacTrac 6.x. is software used to place patients at an accurately defined point within the treatment beam of a medical accelerator for stereotactic radiosurgery or radiotherapy procedures.ExacTrac 6.x Patient Positioning System: Potentially incorrect patient positioning when using the ExacTrac Cone Beam CT (CBCT) with a CBCT acquired at a couch angle other than 0.0 degrees.accessdata.fda.gov
February 16, 201570657Class IITerminatedExacTrac versions 6.x patient positioning systems are used to position patients during radiosurgery or radiotherapy procedures..The ExacTrac 6.x Patient Positioning System may incorrectly position the patient when using the ExacTrac Cone Beam CT (CBCT) with a TrueBeam-specific optional subvolume-CBCT.accessdata.fda.gov
January 16, 201570291Class IITerminatedThe Brainlab Offset Cup Impactor Universal. Part of the Brainlab hip system. An intraoperative image-guided localization system to enable minimally invasive orthopedic surgery. (a stereotaxic instrument)The recommended sterilization and drying parameters are not effective to achieve the minimum required sterilization level.accessdata.fda.gov
November 19, 201469960Class IITerminatediPlan RT Dose is a stereotactic radiation treatment planning system that is intended for use in stereotactic, conformal, computer planned, Linac based radiation treatment of cranial, head and neck, and extracranial lesioiPlan RT Radiation Treatment Planning Software: Potentially incorrect patient positioning when using multiple localized CT image data sets.accessdata.fda.gov
June 27, 201468737Class IITerminatedPatient Data Manager 2.0 (Content manager 2.0, Patient Browser 4.0, DICOM Viewer 2.0) Brainlab Digital Lightbox. A system for the display of medical images. Model numbers 25100-05 and 25100-06. The software can transfer The following defects have been identified for data loaded with Patient Data Manager version 2.0 (including subversions 2.0.0, 2.0.1 and 2.0.2): 1) When loading non-square pixel image data with PDM 2.0, the data set is not correctly transferred and displayed in the corresponding Brainlab navigation or planning software. When a data set is loaded, the pixels accessdata.fda.gov
June 24, 201468741Class IITerminatedExacTrac is intended to be used to place patients at an accurately defined point within the treatment beam of a medical accelerator for stereotactic radiosurgery or radiotherapy procedures, in order to treat lesions, tumWhen using multiple isocenters (radiation treatment targets) within a single plan, in certain workflow conditions ExacTrac v.6.0.4 might move the patient to an unintended isocenter position, despite displaying the green "OK" icon. If this anomaly occurs and is not detected by the user, the radiation treatment dose at the linear accelerator may be delivered taccessdata.fda.gov
May 21, 201468845Class IITerminatedNavigation Spine & Trauma 3D Version 2.0 and 2.1 Is intended as an intraoperative image-guided localization system to enable minimally invasive surgery. It links a freehand probe, tracked by a passive marker sensor systeBrainlab Navigation Software Spine & Trauma 3D 2.0/2.1 offers automatic registration of intraoperatively acquired CT image data sets. To enable automatic registration, the software requires the gantry position of the scanner. The gantry position can either be entered manually or submitted automatically from the CT scanner. If automatic gantry communication iaccessdata.fda.gov
April 15, 201467926Class IITerminatedExacTrac 5.5, an Image Processing System used for patient positioning for radiation therapy or radiosurgery.When using a specific plan update workflow in combination with a non-Brainlab treatment planning system (TPS), there is a possibility in ExacTrac 5.5.5 to generate an unintended blend of two initially separate plans of the same patient.accessdata.fda.gov
February 24, 201467719Class IITerminatedExacTrac 6.0 is a patient positioning and monitoring system. Model/catalogue numbers: 20833B EXACTRAC 6.0 IR POSITIONING SOFTWARE 49936 ET SOFTWARE UPDATE 6.0.X TO 6.0.3 49926B ET UPGRADE SOFTWARE 3.X TO 6.0 (IR+XR) 4993When using multiple radiation treatment targets within a single plan, the ExacTrac v.6.0.3 might position the patient to an unintended radiation treatment point. As a result, there is a possibility that the radiation treatment dose may be delivered to the unintended target position.accessdata.fda.gov
November 18, 201367569Class IITerminatedBrainlab, Spine & Trauma 3D 2.0, Navigation Software. An intraoperative image-guided localization system to enable minimally invasive surgery. Catalog Number: 22264The "fluoro match registration" function of the Navigation Software Spine & Trauma 3D 2.0 allows the user to intraoperatively match e.g., CT data sets to the current patient anatomy visible on fluoroscopic images, used by the navigation software during spinal surgeries to display the position and orientation of instruments. For this registration function in accessdata.fda.gov
November 15, 201367017Class IITerminatedBrainLAB's VectorVision spine is intended for use as an intraoperative image-guided localization system for minimally invasive surgery. It links a freehand probe, tracked by a passive marker sensor system to virtual compBrainlab has determined that pins of thee Instrument Star Unit ML (Calibration with ICM4) with specific serial numbers might have been made of an incorrect material that is not suitable for the necessary disinfection and sterilization of the product. If corrosion occurs and is not detected by the user, and the device is used during surgery, corroded particleaccessdata.fda.gov
July 16, 201365773Class IITerminatedBRAINLAB; FRAMELESS SRS QA TARGET POINTER Robotics is a device used to compensate rotational patient misalignment (roll and pitch) in a linear accelerator environment for stereotactic radiosurgery or radiotherapy proceduThe Frameless SRS QA Target Pointer - Pointer Cap with the engraved cross hairs may become loose even when only a moderate force is applied to the Pointer Cap.accessdata.fda.gov
April 22, 201371924Class ITerminatedBrainlab Cranial Navigation System: An Image Guided Surgery System / Stereotactic. Radiology Departments. The BrainLAB Cranial IGS System is intended to be an intra-operative image guided localization system to enable miSoftware Error: The effect of setup on overall navigation accuracy could potentially intensify small inaccuracies arising from individual steps of a complex navigation procedure that may cause an inaccurate display of instruments by the navigation system compared to the actual patient anatomy.accessdata.fda.gov
August 12, 200952988Not yet classifiedTerminatedBrainLab Radiotherapy Treatment Planning Software; Catalog number 20610 - Radiosurgery 3.0 Catalog number 20620 - Radiosurgery 3.5 and Catalog number 20630 - Circular ARC SRS/SRT Planning. The software is intended for usFailure to conduct important safety checks when using the BrainLab radiotherapy treatment planning software in combination with BrainLab conical collimators could result in unintended radiation outside the conical shaped field, which may lead to serious injury of the patient.accessdata.fda.gov
March 19, 200951484Not yet classifiedTerminatedBrainLab Micro-Multileaf-Collimator, model 41600; BrainLab AG, Kapellenstrasse 12, 85622 Feldkirchen, Germany. The mMLC is intended to assist the radiation oncologist in the delivery of radiation to well-defined target vThe Integrated Multileaf-Collimator (MLC) of the linear accelerator could interfere with the intended conformal fields of the BrainLab m3 micro-Multileaf-Collimator (mMLC) during patient treatment.accessdata.fda.gov
November 12, 200748682Not yet classifiedTerminatedVectorVision (VV) Sky Navigation Platform (19" Computer Rack); the 19" computer rack is a component of the VVsky Vario, BrainSUITE iMRI, BrainSUITE NET and BrainSUITE iCT systems; BrainLab AG, Kapellenstrasse 12, 85622 FDiameter of cables used for installation are to small for the applied current. If an internal short circuit is produced the medical power supply will not shut down automatically and will continue to deliver current, which could result in overheating cables.accessdata.fda.gov
June 5, 200738170Not yet classifiedTerminatedBrainLAB Target Positioner for Leksell Headring used with the iPlan RT Dose (versions 3.0, 3.0.1 and 3.0.2) and BrainSCAN (version 5.31) Radiotherapy Treatment Planning Software,; BrainLab AG, Ammerthalstrasse 8, 85551 HTarget Alignment Error : A mechanical component/software incompatibility caused by a specific combination of the BrainLAB Target Positioner version 40700-3A for Leksell headrings and BrainLAB planning software resulted in a 1.25 mm shift in target area alignment during radiosurgery treatment.accessdata.fda.gov
June 2, 200635742Not yet classifiedTerminatedExacTrac Robotics, sold alone as Robotic Tilt Module catalog 49720 and in a bundle as catalog 49700, for installation on the Varian Exact Couch, a component of the Novalis Shaped Beam Surgery System; a table tilt device During ExacTrac Robotics installation on the Varian Exact Couch, the couch height position indication is re-calibrated to read out the correct positions. This re-calibration could cause the eventual failure of the vertical lift mechanism of the couch, which might result in patient injury or death.accessdata.fda.gov

Compare with other makers

Updated October 5, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.