Bolder Surgical, LLC: FDA-registered device maker in Louisville, CO, United States, 4 510(k) clearances

Bolder Surgical, LLC is registered with the FDA (registration 3010377594) in Louisville, CO, United States. It lists 3 device types. The FDA files 4 510(k) clearances under its listings, the newest dated September 7, 2021. 3 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3010377594
Address
331 S. 104th Street Suite 200, Louisville, CO, United States, 80027
Owner or operator
HOLOGIC, INC. (9007676)
Roles
Specification developer
First device listed
January 4, 2023
Registered through
2026
Brand names listed
CoolSeal Mini; CoolSeal Generator, CoolSeal Reveal, CoolSeal Trinity, JustRight 5mm Reload; JustRight 5mm Stapler

Devices it lists

DeviceProduct codeClassRoleSource
Electrosurgical, Cutting & Coagulation & AccessoriesGEI2Specification developeraccessdata.fda.gov
Staple, ImplantableGDW2Specification developeraccessdata.fda.gov
Stapler, SurgicalGAG2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
September 7, 2021K211579CoolSeal Trinity (30 cm shaft), CoolSeal Trinity (37 cm shaft), CoolSeal Trinity (44 cm shaft)GEISubstantially EquivalentBolder Surgical, LLCaccessdata.fda.gov
May 6, 2021K203640CoolSeal RevealGEISubstantially EquivalentBolder Surgical, LLCaccessdata.fda.gov
October 6, 2020K202114CoolSeal Generator/CSL-200-50, CoolSeal Trinity (30 cm shaft)/CSL-TR105-30, CoolSeal Trinity (37 cm shaft)/CSL-TR105-37, CoolSeal Trinity (44 cm shaft)/CSL-TR105-44, CoolSeal Mini (20cm shaft)/CSL-MN103-20GEISubstantially EquivalentBolder Surgical, LLCaccessdata.fda.gov
February 11, 2014K132472JUSTRIGHT 5MM STAPLER, JUSTRIGHT 5MM RELOADGDWSubstantially EquivalentJustright Surgical, LLCaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
January 25, 202289570Class IITerminatedCoolSeal Generator, REF: CSL-200-50A potential manufacturing/assembly defect could result in the generator not meeting IEC 60601 standards for medical electrical equipment, and it can potentially, under specific conditions, lead to the delivery of unintended energy to the patient.accessdata.fda.gov
June 11, 201571521Class IITerminatedJustRight 5mm Stapler, JR-ST25-2.0 Stapler is packaged in cases of 6, placed in a tray and sealed with a Tyvek lid. Product Usage: The JustRight 5mm Stapler is intended for use in abdominal, gynecologic, pediatric, and tJustRight Surgical is recalling various lots of JustRight 5mm Stapler product because they may deliver incomplete staple formation and incomplete tissue closure.accessdata.fda.gov
August 27, 201469140Class IITerminatedJustright Surgical, JustRight 5mm Stapler, REF JR-ST25-2.0, Sterile, EO, Rx Only, JR-ST25-2.0 product is packaged in cases of 6. The JustRight 5mm Stapler is intended for use in abdominal, gynecologic, pediatric and thorJustRight Surgical is recalling specific lots of JustRight 5mm Stapler and Reload products because they may deliver poor distal staple formation, past the end of the knife cut.accessdata.fda.gov

Compare with other makers

Updated September 7, 2021. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.