Skip to the page

Data / Medical devices / Germany / Black Forest Medical GmbH

Black Forest Medical GmbH: FDA-registered device maker in FREIBURG Baden-Wurttemberg, Germany, 8 510(k) clearances

Black Forest Medical GmbH is registered with the FDA (registration 3003923584) in FREIBURG Baden-Wurttemberg, Germany. It lists 6 device types. The FDA files 8 510(k) clearances under its listings, the newest dated April 24, 2024. 3 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3003923584
Address
Boetzinger Strasse 86, FREIBURG Baden-Wurttemberg, Germany, 79111
Owner or operator
Black Forest Medical GmbH (9041863)
Roles
Manufacturer
First device listed
November 19, 2007
Registered through
2026
Brand names listed
Cranial Stabilization and, DORO HEADREST, DORO LUCENT® Skull Clamp, DORO LUCENT® Skull Clamp Pediatric Set, DORO LUCENT® iXI and iMRI Headrest System, DORO QR3 Headrest System (Aluminum), DORO QR3 XTom Headholder System, DORO Sterile Disposable Skull Pins (Stainless Steel) , DORO Sterile Disposable Skull Pins (Titanium) and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 24, 2024K240319DORO LUCENT Skull Clamp (1101.001); DORO LUCENT Skull Clamp Pediatric Set (1101.040)HBLSubstantially EquivalentPro Med Instruments GmbHaccessdata.fda.gov
March 29, 2021K203505DORO QR3 Headrest System (Aluminum)HBLSubstantially EquivalentPro Med Instruments GmbHaccessdata.fda.gov
June 2, 2020K193438DORO Sterile Disposable Skull Pins (Stainless Steel) , DORO Sterile Disposable Skull Pins (Titanium)HBLSubstantially EquivalentPro Med Instruments GmbHaccessdata.fda.gov
February 21, 2020K191740DORO LUCENT® iXI and iMRI Headrest SystemHBLSubstantially EquivalentPro Med Instruments GmbHaccessdata.fda.gov
October 22, 2019K191979DORO QR3 XTom Headholder SystemHBLSubstantially EquivalentPro Med Instruments GmbHaccessdata.fda.gov
May 21, 2007K063494DORO RADIOLUCENT HEADREST SYSTEM ( ALSO MRI-COMPATIBLE) AND COMPONENTSHBLSubstantially EquivalentPro-Med Instruments GmbHaccessdata.fda.gov
November 20, 2003K032331DORO RADIOLUCENT HEADREST SYSTEM AND HORSESHOE HEADRESTS,AND NON-RADIOLUCENT J-ARM RETRACTOR SYSTEM (ALUMINUM ALLOY)HBLSubstantially EquivalentPro-Med Instruments GmbHaccessdata.fda.gov
August 4, 2000K001808DORO HEADREST SYSTEMHBLSubstantially EquivalentPro-Med Instruments GmbHaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
March 14, 202596720Class IIOngoingDORO Easy-Connect Navigation Adaptor; BRAINLAB (item No. 1204.002)Potential of compromised compatibility resulting in influence on the positioning of the reference array and an influence of the function of the navigation system cannot be excluded.accessdata.fda.gov
July 5, 201880628Class ITerminatedDORO LUCENT Base Unit, REF 1101.021 Headrest System used in open and percutaneous craniotomies and spinal surgeriesThe combination of two different design revisions of DORO LUCENT Base Unit, Locking Transitional Member, and Transitional Member within one set up might lead to a malfunction and failure of the headrest system.accessdata.fda.gov
November 2, 201778501Class IITerminatedpmi, pro med instruments, DORO(R) Sterile Disposable Skull Pins, 3 pieces (3 pieces per blister, 12 blisters per box), STERILE R, Rx ONLY The DORO(R) Skull Pins are inserted into the receptacles of the skull clamp and fiThe firm received reports of two breakages of the pin tips which occurred during two identical surgery procedures. The breakage occurred at the very distal end of the conical part of the skull pin tip.accessdata.fda.gov

Compare with other makers

Updated May 28, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.