Data / Medical devices / Denmark / BK Medical Aps
BK Medical Aps: FDA-registered device maker in HERLEV Hovedstaden, Denmark, 7 510(k) clearances
BK Medical Aps is registered with the FDA (registration 9680269) in HERLEV Hovedstaden, Denmark. It lists 5 device types. The FDA files 7 510(k) clearances under its listings, the newest dated October 23, 2023. 5 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 9680269
- FEI number
- 3003705156
- Address
- Mileparken 34, HERLEV Hovedstaden, Denmark, DK-2730
- Owner or operator
- GE HealthCare Technologies Inc. (9912004)
- Roles
- Manufacturer, Specification developer
- First device listed
- October 6, 2023
- Registered through
- 2027
- Brand names listed
- 1202 (Flex Focus), 1300 (bkSpecto), 13L4w, 14L3, 14L3e, 18L5, 18L5s, 2052 and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Automated Radiological Image Processing Software | QIH | 2 | Manufacturer, Specification developer | accessdata.fda.gov |
| Biopsy Needle | FCG | 2 | Specification developer | accessdata.fda.gov |
| System, Imaging, Pulsed Doppler, Ultrasonic | IYN | 2 | Manufacturer, Specification developer | accessdata.fda.gov |
| System, Imaging, Pulsed Echo, Ultrasonic | IYO | 2 | Manufacturer, Specification developer | accessdata.fda.gov |
| Transducer, Ultrasonic, Diagnostic | ITX | 2 | Manufacturer, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| October 23, 2023 | K231764 | Ultrasound System 1300 | IYN | Substantially Equivalent | Bk Medical Aps | accessdata.fda.gov |
| April 11, 2023 | K223830 | Ultrasound System 2300 | IYN | Substantially Equivalent | Bk Medical Aps | accessdata.fda.gov |
| August 1, 2018 | K180737 | Ultrasound Scanner System bk2300 | IYN | Substantially Equivalent | Bk Medical Aps | accessdata.fda.gov |
| February 23, 2018 | K173569 | Ultrasound System 1300 | IYN | Substantially Equivalent | Bk Medical Aps | accessdata.fda.gov |
| January 10, 2014 | K132335 | ULTRASOUND SCANNER FLEX FOCUS 1202 | IYN | Substantially Equivalent | B-K Medical Aps | accessdata.fda.gov |
| February 2, 2009 | K083667 | NEEDLE GUIDE FOR 8814, MODEL UA1335, NEEDLE GUIDE FOR 8815, MODEL UA 1336, NEEDLE GUIDE FOR 8824, MODEL UA 1337 | ITX | Substantially Equivalent | B-K Medical Aps | accessdata.fda.gov |
| July 22, 2008 | K081323 | BIOPSY GUIDE KIT FOR 8808 AND BIPLANE, ENDFIRE AND DUAL BIOPSY GUIDES FOR 8818 | FCG | Substantially Equivalent | B-K Medical Aps | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 9, 2025 | 97830 | Class II | Ongoing | 1202 Flex Focus Ultrasound System, cart models UA1214 and UA1814, used with: Flex Focus 200, Flex Focus 300, Flex Focus 400, Flex Focus 500, Flex Focus 700, Flex Focus 800; System, Imaging, Pulsed Doppler, Ultrasonic | GE HealthCare has become aware that the Instructions for Use within the user guide and service manual do not adequately state the required battery replacement intervals, end-of-life handling procedures, or general battery safety precautions. | accessdata.fda.gov |
| September 4, 2024 | 95431 | Class II | Ongoing | bk3000, model #2300-11; bk3500, model #2300-41; bk5000, model #2300-61; and bkActive 2300, model #2300-66, ultrasound system with battery option. | The internal power connections at the power inlet of the ultrasound devices can come loose resulting in the potential for excessive heat which could lead to a thermal event or the device becoming inoperable. | accessdata.fda.gov |
| November 30, 2023 | 93598 | Class II | Ongoing | bkActiv Ultrasound System 2300, Model numbers 2300-56 and 2300-66. | An issue on the Dual Live Compare feature on the bkActiv system could result in a measurement error. | accessdata.fda.gov |
| June 28, 2016 | 74691 | Class II | Terminated | BK Medical ApS Ultrasound System Scanner bk2300 - Model #: bk3500 with software releases 1.2.0, 1.2.1 and 1.2.2. The system is intended for diagnostic ultrasound imaging or fluid flow analysis of the human body, data pro | In the system (bk3500) software generic volume measurement (HxWxLxl) function the user may be unaware of the calculation factor (1) and assume the generic volume calculation factor is similar to that of the other (prostate, adenoma, testis, kidney, and bladder) volume calculation factors provided in the software. | accessdata.fda.gov |
| September 8, 2008 | 50157 | Not yet classified | Terminated | Single-use sterile puncture attachment UA1256-U used with the BK Medical Ultrasounds: Diagnostic Ultrasound scanner Pro Focus 2202 and Diagnostic Ultrasound Transducer 8667 Diagnostic Ultrasound scanner 2102 and Diagnost | No 510k approved | accessdata.fda.gov |
Compare with other makers
- All makers of Transducer, Ultrasonic, Diagnostic
- All makers of System, Imaging, Pulsed Echo, Ultrasonic
- All makers of System, Imaging, Pulsed Doppler, Ultrasonic
- All makers of Automated Radiological Image Processing Software
- All makers of Biopsy Needle
Updated November 6, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.