Data / Medical devices / United States / BioFire Diagnostics, LLC
BioFire Diagnostics, LLC: FDA-registered device maker in Salt Lake City, UT, United States, 26 510(k) clearances
BioFire Diagnostics, LLC is registered with the FDA (registration 3002773840) in Salt Lake City, UT, United States. It lists 22 device types. The FDA files 26 510(k) clearances under its listings, the newest dated September 22, 2026. 35 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3002773840
- Address
- 515 Colorow Drive, Salt Lake City, UT, United States, 84108
- Owner or operator
- BIOMERIEUX SA (8020790)
- Roles
- Complaint file establishment, Manufacturer, Manufacturer for export, Specification developer
- First device listed
- October 24, 2014
- Registered through
- 2026
- Brand names listed
- BIOFIRE BCID2 Panel, BIOFIRE Blood Culture Identification 2 Panel, BIOFIRE FILMARRAY BCID2 Panel, BIOFIRE FILMARRAY GI Panel, BIOFIRE FILMARRAY GI Panel Mid, BIOFIRE FILMARRAY Gastroinestinal (GI) Panel, BIOFIRE FILMARRAY Gastrointestinal (GI) Panel, BIOFIRE FILMARRAY Gastrointestinal (GI) Panel Mid and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| September 22, 2026 | K263054 | BIOFIRE Respiratory Panel 2.1 (RP2.1) | QOF | Substantially Equivalent | Biofire Diagnostics | accessdata.fda.gov |
| August 14, 2025 | K243544 | BIOFIRE SPOTFIRE Respiratory/Sore Throat Panel Mini | QOF | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| January 16, 2025 | K243885 | BIOFIRE FILMARRAY Gastrointestinal (GI) Panel Mid | PCH | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| December 20, 2024 | K243759 | BIOFIRE Blood Culture Identification 2 (BCID2) Panel (RFIT-ASY-0147 (30 pack) RFIT-ASY-0148 (6 pack)) | PEN | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| December 5, 2024 | K243463 | BIOFIRE FILMARRAY Tropical Fever Panel | QMV | Substantially Equivalent | Biofire Diagnostics, LLC (Biomerieux) | accessdata.fda.gov |
| November 7, 2024 | K242367 | BIOFIRE FILMARRAY Gastrointestinal (GI) Panel | PCH | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| November 6, 2024 | K243222 | BIOFIRE® FILMARRAY® Pneumonia Panel (BIOFIRE Pneumonia Panel); BIOFIRE® FILMARRAY® Pneumonia Panel plus (BIOFIRE Pneumonia Panel plus) | QDS | Substantially Equivalent | Biofire Diagnostics, LLC (Biomerieux) | accessdata.fda.gov |
| May 30, 2024 | K241194 | BIOFIRE SPOTFIRE Respiratory/Sore Throat (R/ST) Panel Mini | QOF | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| March 26, 2024 | K232954 | BIOFIRE SPOTFIRE Respiratory/Sore Throat (R/ST) Panel | QOF | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| April 13, 2023 | K230719 | BIOFIRE® SPOTFIRE® Respiratory (R) Panel Mini | QOF | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| March 16, 2023 | K230404 | BIOFIRE FILMARRAY Gastrointestinal (GI) Panel | PCH | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| February 3, 2023 | K213954 | BIOFIRE SPOTFIRE Respiratory (R) Panel | QOF | Substantially Equivalent | Biofire Diagnostics | accessdata.fda.gov |
| October 27, 2022 | K222601 | FilmArray Pneumonia Panel plus | QDS | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| April 29, 2022 | DEN200066 | BioFire Joint Infection (JI) Panel | QSN | Unknown | Biofire Diagnostics, LLC | accessdata.fda.gov |
| September 22, 2021 | K212727 | FilmArray Pneumonia Panel | QDP | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| March 17, 2021 | DEN200031 | BioFire Respiratory Panel 2.1 (RP2.1) | QOF | Unknown | Biofire Diagnostics, LLC | accessdata.fda.gov |
| March 18, 2020 | K193519 | BioFire Blood Culture Identification 2 (BCID2) Panel | PEN | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| November 15, 2018 | K181324 | FilmArray Pneumonia Panel plus | QDS | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| November 9, 2018 | K180966 | FilmArray Pneumonia Panel | QDP | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| April 1, 2016 | K160459 | FilmArray Gastrointestinal Panel (GI) for use with FilmArray Torch | PCH | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| March 17, 2016 | K160462 | FilmArray Meningitis/Encephalitis (ME) Panel for use with FilmArray Torch | PLO | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| February 8, 2016 | K160068 | FilmArray Respiratory Panel (RP) for use with FilmArray Torch | OCC | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| October 8, 2015 | DEN150013 | FilmArray Meningitis/Encephalitis(ME) Panel | PLO | Unknown | Biofire Diagnostics, LLC | accessdata.fda.gov |
| February 19, 2015 | K143005 | FilmArray Gastrointestinal (GI) Panel for use with the FilmArray 2.0 | PCH | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| January 30, 2015 | K143178 | FilmArray 2.0 System | NSU | Substantially Equivalent | Biofire Diagnostics, LLC | accessdata.fda.gov |
| May 2, 2014 | K140407 | FILMARRAY GASTROINTESTINAL (GI) PANEL | PCH | Substantially Equivalent | Biofire Diagnostics | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 12, 2026 | 99592 | Class II | Ongoing | Generic Name: FilmArray Pneumonia Panel Generic Name: FilmArray Pneumonia Panel Model/Catalog Number: RFIT-ASY-0144 (30 pack), RFIT-ASY-0145 (6 pack), FLM1-ASY-0150 (Verification Kits). Verification kit lots (FLM1-ASY-01 | Due to potential contaiminated of spefic lots of pneumonia and joint infection panels that could result in false positive results | accessdata.fda.gov |
| June 24, 2026 | 99261 | Class II | Ongoing | BIOFIRE Respiratory Panel 2.1 (RP2.1) REF 423742 UDI code: 00815381020529 PCR-based multiplexed nucleic acid test, in vitro diagnostic | Due to increase in false negative results | accessdata.fda.gov |
| April 22, 2026 | 98776 | Class II | Ongoing | BioFire Joint Infection (JI) Panel REF: RFIT-ASY-0138, 30 test Kit. | Contamination to in-vitro diagnostic test may result in false positives. | accessdata.fda.gov |
| April 1, 2026 | 98719 | Class II | Ongoing | Biofire Spotfire Respiratory/Sore Throat Panel REF: 423485 | Respiratory/sore throat panel test may result in false negative results and control failures. | accessdata.fda.gov |
| October 22, 2025 | 97870 | Class II | Ongoing | BioFire Respiratory Panel 2.1, IVD, REF: 423742 (30 test kit) | Due to unintended movement of pouch chemistry, nucleic acid test may result in elevated risk of false negative results and risk of control failures. | accessdata.fda.gov |
| April 30, 2025 | 96835 | Class II | Ongoing | BioFire Respiratory Panel 2.1 plus Kit, REF: 423740, For Filmarray systems | Due to manufacturing error, respiratory panel may result in elevated control failures and/or false negative results. | accessdata.fda.gov |
| February 27, 2025 | 96346 | Class II | Ongoing | FilmArra Pneumonia Panel plus (Pneumoplus), REF: RFIT-LBL-0374 | Increased risk of control failures and false negative test results with multiplexed nucleic acid test. | accessdata.fda.gov |
| August 7, 2024 | 95019 | Class II | Ongoing | FILMARRAY 2.0 INSTRUMENT, REF: FLM2-ASY-0001, FLM2-ASY-0001-W | Some automated in vitro diagnostic modules and instruments manufactured or serviced between May 2022 and May 2024 were calibrated with internal equipment that may lead modules and instruments to report higher melting temperatures, which may lead to erroneous results including false positive Salmonella, Giardia lamblia, false positive/negative Norovirus, and | accessdata.fda.gov |
| June 19, 2024 | 94886 | Class II | Ongoing | BIOFIRE Blood Culture Identification 2 (BCID2) Panel, REF: RFIT-ASY-0147, for FILMARRAY Systems, when used in conjunction with Culture Media Bottles: BACT/ALERT FA PLUS, REF: 410851, and BACT/ALERT PF PLUS, REF: 410853 | If blood culture identification panel is used in conjunction with specific lots of culture media bottles, then false positive Serratia marcescens results may occur, due to an increased level of non-viable organism from serratia marcescens targets in culture media bottles, false positive result may lead to an inappropriate change in patient therapy. | accessdata.fda.gov |
| June 10, 2024 | 94942 | Class II | Ongoing | BIOFIRE FILMARRAY Pneumonia Panel, REF: RFIT-ASY-0144 | Pneumonia panels have an increased risk of control failures due to an issue in the manufacturing process, which could lead to delayed results for the customer. | accessdata.fda.gov |
| May 16, 2024 | 94992 | Class II | Ongoing | BIOFIRE FILMARRAY Gastrointestinal (GI) Panel REF RFIT-ASY-0116 (30 test kit) BIOFIRE FILMARRAY Gastrointestinal (GI) Panel REF RFIT-ASY-0104 (6 kit test) The BIOFIRE FILMARRAY Gastrointestinal (GI) Panel is a qualitativ | Due to increase of false positive Vibrio/Vibrio Cholerae results when using a certain transport medium. | accessdata.fda.gov |
| January 26, 2024 | 93639 | Class II | Ongoing | FilmArray Gastrointestinal (GI) Panel RFIT-ASY-0116 (30 test kit) RFIT-ASY-0104 (6 test kit) Gastrointestinal microorganism multiplex nucleic acid-based assay. In vitro diagnostic. | Due to potential signals of increased false positive Norovirus results when using the gastrointestinal (GI) panel. | accessdata.fda.gov |
| January 26, 2024 | 93636 | Class II | Ongoing | BIOFIRE Blood Culture Identification 2 (BCID2) Panel when used with: BD BACTEC Lytic Anaerobic medium BD BACTEC Peds Plus medium BD BACTEC Plus Aerobic medium BD BACTEC Plus Anaerobic medium BD BACTEC Standard Aerobic me | Due to a trend in false positive Candida tropicalis results on blood culture panel when using certain BD BACTEC vial mediums | accessdata.fda.gov |
| December 14, 2023 | 93592 | Class II | Ongoing | FilmArray Pneumonia Panel Plus (Pneumoplus), REF: RFIT-ASY-0143, CED 2797, IVD, Rx Only (30 test kit) | Their is a potential for false positive results when using Pneumonia panel. | accessdata.fda.gov |
| November 27, 2023 | 93526 | Class II | Ongoing | BIOFIRE FILMARRAY Gastrointestinal (GI) Panel is a qualitative multiplexed nucleic acid-based in vitro diagnostic test intended for use with BIOFIRE FILMARRAY Systems. | A manufacturing event may contribute to elevated rates of false negative results while using gastrointestinal panel and respiratory panel, which could lead to inappropriate antibiotic treatment, no treatment, delay of treatment, and may provide false assurance to someone with a true infection, delayed identification of an outbreak, and may result in addition | accessdata.fda.gov |
| October 17, 2023 | 93360 | Class II | Ongoing | BIOFIRE Blood Culture Identification 2 (BCID2) Panel, REF: RFIT-ASY-0147, used with Maine Molecular Quality Controls, Inc (MMQCI) FilmArray BCID2 Control Panel M416, which is referenced in Quality Control Materials for u | Routine quality control testing of affected blood culture identification panel with affected control panel may need to be amended, due to control panel/instrument characteristic changes, that lead C. tropicalis to be amplified in some portion of test runs, but then it's reported as "Not Detected" because the assay amplicon Tm is outside the acceptable limit | accessdata.fda.gov |
| October 17, 2023 | 93268 | Class II | Ongoing | FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scanner, touch screen computer and USB ports. The BioFire FilmArray Torch (BioFire Torch) is an automated in vitro diagnos | Due to an increased risk of degradation of the power entry switch resulting from arcing inside of the power switch that may result in carbon build-up on the switch contacts. The carbon build-up may lead to excess heating inside of the power switch, subsequently leading to deformation of the power switch case. The deformation can create an opportunity for a p | accessdata.fda.gov |
| May 8, 2023 | 92397 | Class II | Ongoing | BioFire Respiratory Panel 2.1 (RP2.1), REF: 423742, For FILMARRAY systems, IVD, Rx Only | Due to manufacturing issue, panels may result in false negative results. | accessdata.fda.gov |
| April 25, 2023 | 92885 | Class II | Ongoing | FILMARRAY Gastrointestinal (GI) Panel (Part No.: RFIT-ASY-0104 & RFIT-ASY-0116) Pouch Module Software | The firm has identified an increased risk of obtaining false positive Cryptosporidium results from customers using the BIOFIRE FILMARRAY Gastrointestinal (GI) Panel | accessdata.fda.gov |
| March 8, 2023 | 91892 | Class II | Ongoing | FilmArray Gastrointestinal (GI) Panel for FILMARRAY Systems, REF: RFIT-ASY-0116, (30 pouches/kit) | Due to manufacturing issue, Gastrointestinal (GI) Panel may result in false negative results. | accessdata.fda.gov |
| February 1, 2023 | 91647 | Class II | Ongoing | In Vitro Diagnostic (IVD) Panel BioFire BCID2 Panel - REF RFIT-ASY-0147 | Due to temperature excursions with products (products being stored outside of the required temperature specifications) that may cause a reduction in performance. The temperature excursion was as a result of shipping delays. | accessdata.fda.gov |
| October 11, 2021 | 88934 | Class II | Terminated | BioFire Blood Culture Identification 2 (BCID2) Panel Part No: RFIT-ASY-0147 UDI: 00815381020338 Blood Culture Catalog No./Description: 442023/BD BACTEC Plus Aerobic medium in plastic vials 442021/BD BACTEC Lytic Anaerobi | Due to an increased risk of false positive Acinetobacter calcoaceticus- baumannii complex results. The cause may be as a due to non-viable contamination in the blood culture vials. | accessdata.fda.gov |
| July 20, 2021 | 88410 | Class II | Terminated | FilmArray Blood Culture Identification (BCID) Panel Product Pouch Label: FilmArray BCID Panel Part No: RFIT-ASY-0126 Part No: RFIT-ASY-0127 | Due to product complaints received for false negative results (dropouts) with blood culture identification panel potential caused by a pouch manufacturing error. | accessdata.fda.gov |
| June 7, 2021 | 88117 | Class II | Terminated | FilmArray Pneumonia Panel (Pneumo) Part Numbers: Part No: RFIT-ASY-0144 / UDI: 00815381020178 (30 test kit) Part No: RFIT-ASY-0145 / UDI: 00815381020185 (6 test kit) | Due to real-time stability study failures resulting in increase rate of false negative results between the 6 to 12 month expiry time-frame. | accessdata.fda.gov |
| May 10, 2021 | 87934 | Class II | Terminated | BioFire BCID2 Panel, REF RFIT-ASY-0147, For FilmArray Systems, CE, Blood Culture Identification Panel in vitro diagnostic, Rx Only, UDI: (01)00815381020338 | Elevated rates of false negative results may occur when using blood culture panels due to issues in the manufacturing process. Pouches contained OPP from FilmArray Blood Culture Identification Panel (BCID) instead of OPP from BCID2 Panel. | accessdata.fda.gov |
| April 16, 2021 | 87936 | Class II | Terminated | FilmArray Pneumonia Panel (Penumo) REF RFIT-ASY-0144 | Elevated rates of false positive/false negative and control failures while using the Pneumonia Panel, due to issues identified in the manufacturing process. | accessdata.fda.gov |
| January 26, 2021 | 87282 | Class II | Terminated | Gram-Negative Bacteria And Associated Resistance Markers; Film Array Blood Culture Identification (BCID); Film Array BCID Panel - Product Usage: intended for use with FilmArray systems. Part No: RFIT-ASY-0126 / UDI: 0081 | The firm has identified an increased risk of false positive Pseudomonas aeruginosa when BCID/BCID2 Panels are used with specific BD BACTEC" blood culture vials. | accessdata.fda.gov |
| January 22, 2020 | 85550 | Class II | Terminated | FilmArray BCID Panel, RFIT-ASY-0126, 30, Rx Only, CE, IVD, UDI: 00815381020086 used with the following BACT/ALERT Blood Culture Bottle Catalog No./Description: 410851/BACT/ALERT FA Plus 410852/BACT/ALERT FN Plus 410853/B | There is an increased risk of false positive Proteus results when using the Film Array Blood Culture Identification Panel (BCID) in vitro diagnostic test of blood cultures used in conjunction with specific media types. False positive Proteus results from this test may lead to patients receiving improper antibiotic treatment until culture results are availabl | accessdata.fda.gov |
| August 8, 2019 | 84825 | Class II | Terminated | FilmArray Gastronintestinal (GI) Panel, REF: RFIT-ASY-0104, 6-pack kit, UDI (01)00815381020116, CE IVD, Rx Only | Complaints have been received concerning elevated rates of false negative results while using the Gastrointestinal (GI) Panel. False negative results may lead to incorrect treatment being provided which could potentially lead to more serious health events. | accessdata.fda.gov |
| March 7, 2019 | 82354 | Class II | Terminated | FilmArray BCID Panel, IVD, Rx Only, BioFire Diagnostics, REF: RFIT-ASY-0126, and RFIT-ASY-0127, when used with the following blood culture bottles: Bottle Description/Part Number: BACT/ALERT FA Plus/410851; BACT/ALERT FN | Increased risk of false positive Enterobacteriaceae and Escherichia coli results on affected blood culture identification panels when using certain blood culture bottles. | accessdata.fda.gov |
| March 6, 2019 | 82338 | Class II | Terminated | FilmArray Gastrointestinal (GI) Panel, IVD, Rx Only, Biofire Diagnostics, LLC REF: RFIT-ASY-0104, and RFIT-ASY-0116), Product Usage: The FilmArray Gastrointestinal (GI) Panel is a qualitative multiplexed nucleic acid-bas | Elevated rates of false positive results for Campylobacter and Cryptosporidium have been identified. | accessdata.fda.gov |
| September 10, 2018 | 81197 | Class II | Terminated | -Outer Kit Box (P/N RFIT-LBL-0140) - FilmArray Meningitis/Encephalitis (ME) Panel REF RFIT-ASY-0118 30 For FilmArray systems LOT KIT UDI (01)00815381020123 CE 0086 IVD -Fitment Label (P/N RFIT-LBL-0138) which identifies | Firm identified an issue in the manufacturing process which might contribute to elevated rates of false positive results for HSV-1 while using the ME Panel. Only specific kits are affected. | accessdata.fda.gov |
| September 5, 2018 | 81060 | Class II | Terminated | FilmArray Blood Culture Identification (BCID), IVD, Rx Only, BioFire Diagnostics, LLC, Panel Catalog Numbers/ UDI: RFIT-ASY-0126 (30 test kit)/ 00815381020086, RFIT-ASY-0127 (6 test kit)/ 00815381020093, when used with t | Increased risk of false positive results for Proteus when the product is used with a specific blood culture bottles. | accessdata.fda.gov |
| March 14, 2018 | 79514 | Class II | Terminated | FilmArray BCID Panel (Blood Culture Identification Panel), Catalog numbers RFIT-ASY-0126 (30 test kit) and RFIT-ASY-0127 (6 test kit), when used with all lots of BD BACTEC Blood Culture Bottles, Catalog numbers 442020, 4 | There is an increased risk of false positive Proteus results when the product is used with specific types of BD BACTEC blood culture bottles. | accessdata.fda.gov |
| May 27, 2014 | 68352 | Class II | Terminated | FirmArray Blood Culture Identification (BCID) Panel, Model 2.0 The FilmArray Blood Culture Identification (BCID) Panel is a qualitative multiplexed nucleic acid-based in vitro diagnostic test designed to test positive bl | BioFire has identified an increased risk of false positive results when the FilmArray Blood Culture Identification (BCID) Panel is used with bioMrieux BacT/ALERT Standard Anaerobic (SN) blood culture bottles. False positive results have been observed for Pseudomonas aeruginosa and Enterococcus. | accessdata.fda.gov |
Compare with other makers
- All makers of Fungal Organisms, Nucleic Acid-Based Assay
- All makers of Gram-Negative Bacteria And Associated Resistance Markers
- All makers of Gram-Positive Bacteria And Their Resistance Markers
- All makers of Gastrointestinal Pathogen Panel Multiplex Nucleic Acid-Based Assay System
Updated October 13, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.