Data / Medical devices / United States / Baxter Healthcare Corporation

Baxter Healthcare Corporation: FDA-registered device maker in Medina, NY, United States, 2 510(k) clearances

Baxter Healthcare Corporation is registered with the FDA (registration 1314492) in Medina, NY, United States. It lists 2 device types. The FDA files 2 510(k) clearances under its listings, the newest dated July 28, 2025. 11 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1314492
Address
711 Park Ave., Medina, NY, United States, 14103
Owner or operator
BAXTER HEALTHCARE CORPORATION (1417572)
Roles
Manufacturer, Specification developer
First device listed
May 14, 2018
Registered through
2026
Brand names listed
Spectrum IQ Infusion System with Dose IQ Safety Software, Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)

Devices it lists

DeviceProduct codeClassRoleSource
Infusion Safety Management SoftwarePHC2Manufacturer, Specification developeraccessdata.fda.gov
Pump, InfusionFRN2Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
July 28, 2025K251636Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)FRNSubstantially EquivalentBaxter Healthcare Corporationaccessdata.fda.gov
May 11, 2018K173084Spectrum IQ Infusion System, Dose IQ Safety SoftwareFRNSubstantially EquivalentBaxter Healthcare Corporationaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
March 19, 202187568Class IITerminatedSpectrum IQ - Infusion Pump - Product Usage: intended to be used for the controlled administration of fluids.Potentially defective component in the AC power adapter which may fail over time.accessdata.fda.gov
January 6, 202186788Class IITerminatedInfusion PumpBattery performance issues related to prolonged storage.accessdata.fda.gov
September 18, 201881158Class IITerminatedSPECTRUM IQ INFUSION SYSTEM WITH DOSE IQ SAFETY SOFTWARE, 3570009If an operator attempts to manually program a Basic Infusion for a drug that is not included in the Drug Library using the Basic-Dose Mode, the operator will receive a false hard limit exceeded error, preventing him or her from programming the infusion.accessdata.fda.gov
June 21, 201880355Class IITerminatedBaxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6), product code 35700BAX - Product Usage: The Baxter SIGMA Spectrum Infusion Pump with Master Drug Library is intended to be used for the controlled The flow rate test verification was not properly executed for certain Sigma Spectrum infusion pumps prior to release. The testing was performed for less than the required minimum run time. Improperly performed flow rate testing may not identify issues with pumps that could cause inaccuracies in flow rates which, in turn, could lead to over- or under- infusioaccessdata.fda.gov
May 8, 201880014Class IITerminatedBaxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6), infusion pump, 35700BAX and 35700ABB Product Usage: The Baxter SIGMA Spectrum Infusion Pump with Master Drug Library is intended to be used for thThe firm will be updating the Instructions for Use for the product. Current IFUs instruct users to lower the primary bag 20 inches below the secondary bag using a hanger when performing a secondary infusion. However, the firm supplies 12.5-inch hangers with the Baxter disposable secondary sets.accessdata.fda.gov
April 3, 201879815Class IITerminatedBaxter Sigma Spectrum Infusion Pump with master Drug Library (Version 6) 35700BAX Product Usage: The Baxter Sigma Spectrum Infusion Pump with master Drug Library is intended to be used for the controlled administration oService technician improperly documented final release testing on product, indicating that the full battery of release tests were performed when, in fact, several tests were omitted. he omitted tests include air-in-line detection at 400ml/hr and 800ml/hr and verification of upstream occlusion detection at 800ml/hr. Improper detection of air-in-line or upstreaccessdata.fda.gov
October 6, 201779177Class IITerminatedBaxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6) (GTIN 00085412091570); Model Numbers: 35700BAX and 35700ABB. Intended to be used for the controlled administration of fluids.Certain infusion pumps may exhibit excessive wear of the pumping mechanism caused by a lack of lubrication, this could affect the occlusion of the tubing and result in over- or under-infusion.accessdata.fda.gov
January 26, 201776364Class IITerminatedBaxter SIGMA Spectrum Infusion Pump with Master Drug Library, Model #/Product Code 35700BAX2SIGMA Spectrum Infusion Pumps with Master Drug Library, Software V8.00.02 contains an anomaly that may cause a Sharp Watchdog Timeout error message. Specifically, the software anomaly causes the error message only under conditions in which a message is being written to the Spectrum Infusion Pumps Event History Log (EHL), and the length of that message exactlaccessdata.fda.gov
April 23, 201261691Class IIITerminatedSIGMASpectrum Infusion Pump Master Drug Library (MDL) Editor software. Product Usage: A customized in-house library of all IV and epidural drugs, along with their safe delivery parameters.Sigma is a safety alert for the Master Drug Library (MDL) Editor software associated with the SIGMA Spectrum Infusion Pump System because it may result in a facility drug library that does not represent common clinical practices.accessdata.fda.gov
July 6, 201161355Class ITerminatedSigma Spectrum VOLUMETRIC INFUSION PUMP, with or without Master Drug Library, Part Number 35700 -- Common/Classification Name: Infusion Pump -- Class 2 medical device -- SIGMA LLC, Medina, NY 14103 Product Usage: The SpeRecall expansion; the infusion pumps have the potential to fail causing inaccurate flow conditions during use. These conditions range from back flow to free flow, which could result in over-infusion. Sigma's evaluation of subsequent complaints involving failed bearings indicated that the loss or degradation of bearing lubricant to be a more significant contraccessdata.fda.gov
September 15, 201056833Not yet classifiedTerminatedSigma Spectrum VOLUMETRIC INFUSION PUMP, with or without Master Drug Library, Part Number 35700 -- Common/Classification Name: Infusion Pump --Class 2 medical device -- SIGMA LLC, Medina, NY 14103 -- Shipping box label: The infusion pumps have the potential to fail causing inaccurate flow conditions during use. These conditions range from back flow to free flow, which could result in over-infusion.accessdata.fda.gov

Compare with other makers

Updated July 28, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.