Data / Medical devices / United States / Bard Brachytherapy, Inc
Bard Brachytherapy, Inc: FDA-registered device maker in Carol Stream, IL, United States, 4 510(k) clearances
Bard Brachytherapy, Inc is registered with the FDA (registration 1424526) in Carol Stream, IL, United States. It lists 2 device types. The FDA files 4 510(k) clearances under its listings, the newest dated May 2, 2014. 1 recall event names it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1424526
- FEI number
- 3002942387
- Address
- 295 E. Lies RD., Carol Stream, IL, United States, 60188
- Owner or operator
- C. R. Bard, Inc. (2212754)
- Roles
- Manufacturer, Specification developer
- First device listed
- December 16, 1999
- Registered through
- 2027
- Brand names listed
- BrachySource Seed Implants, BrachyStar Brachytherapy Needles, BrachyStar Needles, Brachysource Seed Implants with Sourcecap Bioabsorbable Caps, Palladium-103 Seed Implant Kits, QuickLink Delivery System, QuickLink Loader, QuickLink Relay System and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Source, Brachytherapy, Radionuclide | KXK | 2 | Manufacturer | accessdata.fda.gov |
| System, Applicator, Radionuclide, Manual | IWJ | 1 | Manufacturer, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 2, 2014 | K140856 | BRACHYSOURCE SEED IMPLANTS WITH SOURCECAP BIOABSORBABLE CAPS | KXK | Substantially Equivalent | C.R. Bard, Inc. | accessdata.fda.gov |
| December 23, 2009 | K093663 | RADIONUCLIDE BRACHYTHERAPY SOURCE | KXK | Substantially Equivalent | C.R. Bard, Inc. | accessdata.fda.gov |
| April 19, 2006 | K060636 | PALLADIUM-103 SEED IMPLANT KITS -MULTIPLE | KXK | Substantially Equivalent | C.R. Bard, Inc. | accessdata.fda.gov |
| March 28, 2003 | K023210 | SEEDLINKS, MODELS 70301, 70302, 70303 | KXK | Substantially Equivalent | Sourcetech Medical, LLC | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| April 10, 2018 | 79972 | Class II | Terminated | BARD BrachySource Iodine125 radioactive seeds consist of a welded titanium capsule containing the I125 absorbed onto a nickel / copper-coated, gold-cored aluminum wire (reference Figure 1 below). The I125 has a half-life | Bard Medical Division is recalling the BARD BrachySource Iodine125 Radioactive Seeds in Mick Applicators and BARD BrachySource Iodine125 Radioactive Seeds Loose in Vial with Sterile Spacers. Because the incorrect dosage level radioactive seeds were mixed up and sent to two hospitals. One Hospital ordered BrachySource Iodine125 0.36 mCi radioactive seeds but | accessdata.fda.gov |
Compare with other makers
- All makers of Source, Brachytherapy, Radionuclide
- All makers of System, Applicator, Radionuclide, Manual
Updated April 27, 2018. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.