Data / Medical devices / United States / Angiodynamics, Inc.

Angiodynamics, Inc.: FDA-registered device maker in Queensbury, NY, United States, 63 510(k) clearances

Angiodynamics, Inc. is registered with the FDA (registration 1319211) in Queensbury, NY, United States. It lists 25 device types. The FDA files 63 510(k) clearances under its listings, the newest dated March 24, 2026. 28 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1319211
Address
603 Queensbury Ave., Queensbury, NY, United States, 12804
Owner or operator
ANGIODYNAMICS, INC (9028212)
Roles
Complaint file establishment, Contract manufacturer, Manufacturer
First device listed
February 8, 2000
Registered through
2026
Brand names listed
16 Gauge Entry Needle, Accu-Vu Sizing Catheters, AlphaVac MMA F1885 System, AlphaVac Multipurpose Mechanical Aspiration (MMA) System, AlphaVac Multipurpose Mechanical Aspiration (MMA) System F18 85, AlphaVac Multipurpose Mechanical Aspiration System F1885, AngiOptic Angiographic Catheters, AngioVac and more

Devices it lists

DeviceProduct codeClassRoleSource
Apparatus, Suction, Operating-Room, Wall Vacuum PoweredGCX2Manufactureraccessdata.fda.gov
Aspiration Thrombectomy CatheterQEZ2Complaint file establishment, Manufactureraccessdata.fda.gov
Cannula, CatheterDQR2Manufactureraccessdata.fda.gov
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary BypassDWF2Manufactureraccessdata.fda.gov
Catheter, Continuous FlushKRA2Manufactureraccessdata.fda.gov
Catheter, Intravascular, DiagnosticDQO2Manufactureraccessdata.fda.gov
Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 DaysLJS2Contract manufactureraccessdata.fda.gov
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 DaysFOZ2Contract manufactureraccessdata.fda.gov
Catheter, IrrigationGBX1Manufactureraccessdata.fda.gov
Catheter, Nephrostomy, General & Plastic SurgeryGBO1Manufactureraccessdata.fda.gov
Dilator, Vessel, For Percutaneous CatheterizationDRE2Manufactureraccessdata.fda.gov
Introducer, CatheterDYB2Manufactureraccessdata.fda.gov
Low Energy Direct Current Thermal Ablation SystemOAB2Manufactureraccessdata.fda.gov
Mechanical Thrombolysis CatheterQEY2Manufactureraccessdata.fda.gov
Midline CatheterPND2Contract manufactureraccessdata.fda.gov
Needle, Hypodermic, Single LumenFMI2Manufactureraccessdata.fda.gov
Peripheral Mechanical Thrombectomy With AspirationQEW2Manufactureraccessdata.fda.gov
Port & Catheter, Implanted, Subcutaneous, IntravascularLJT2Manufactureraccessdata.fda.gov
Powered Laser Surgical InstrumentGEX2Manufactureraccessdata.fda.gov
Set, Administration, IntravascularFPA2Manufactureraccessdata.fda.gov
Stents, Drains And Dilators For The Biliary DuctsFGE2Manufactureraccessdata.fda.gov
System, Ablation, Microwave And AccessoriesNEY2Manufactureraccessdata.fda.gov
TrocarDRC2Manufactureraccessdata.fda.gov
Tubing, Pump, Cardiopulmonary BypassDWE2Manufactureraccessdata.fda.gov
Wire, Guide, CatheterDQX2Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
March 24, 2026K253198NanoKnife Generator (H78720300351US0)OABSubstantially EquivalentAngiodynamicsaccessdata.fda.gov
November 24, 2025K252509AlphaVac Multipurpose Mechanical Aspiration System F1885QEZSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
October 24, 2025K253106AngioVac CannulaDWFSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
December 6, 2024K242687NanoKnife Generator (H78720300301US0); NanoKnife Single Electrode Activation Probe, 15 cm (H787204001090); NanoKnife Single Electrode Activation Probe, 25 cm (H787204001100); NanoKnife Single Electrode Probe Spacer (H787204003010)OABSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
April 1, 2024K240397AlphaVac MMA F1885 System (H787253020)QEZSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
July 20, 2023K231945VenaCure EVLT NeverTouch Procedure Kits; VenaCure EVLT NeverTouch Direct Procedure KitsGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
March 27, 2023K223581Solero Microwave Tissue Ablation (MTA) System and AccessoriesNEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
March 7, 2023K221883Solero Microwave Tissue Ablation (MTA) System and AccessoriesNEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
April 4, 2022K213388AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 SystemQEZSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
December 3, 2021K213067Solero Microwave Tissue Ablation (MTA) System and AccessoriesNEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
September 30, 2021K212386AngioVac F18 85DWFSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
June 4, 2021K211081AlphaVac Multipurpose Mechanical Aspiration (MMA) SystemQEZSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
September 15, 2020K202347UNIFUSE Infusion System with Cooper WireQEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
June 1, 2020K192864UNI*FUSE Infusion System with Cooper WireQEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
May 22, 2020K190559SmartPort+ Implantable Ports, SmartPort Plastic Implantable PortsLJTSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
July 5, 2019K190594AngioVac C20, AngioVac C180DWFSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
June 18, 2019K183385NanoKnife SystemOABSubstantially EquivalentAngiodynamicsaccessdata.fda.gov
February 28, 2019K182250Solero MTA Cart, Solero MTA System, Solero microwave Tissue Ablation Applicator (14cm), , Solero microwave Tissue Ablation Applicator (19cm), Solero microwave Tissue Ablation Applicator (29cm)NEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
July 18, 2018K173762AngioDynamics, Inc. Soft-Vu and Mariner Angiographic CathetersDQOSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
July 5, 2018K181044400um Perforator and Accessory Vein Ablation KitGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
August 24, 2017K171921VenaCure EVLT NeverTouch Procedure KitGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
July 19, 2017K170775Mini Stick ENVI Non-Vascular Introducer KitDYBSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
May 30, 2017K170695VenaCure EVLT NeverTouch Direct Introducer SheathDYBSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
May 30, 2017K163356Pulse* Spray Infusion System, Uni*Fuse Infusion SystemQEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
May 5, 2017K162449Solero MTA System, Solero Microwave Tissue Ablation Applicator (14cm), Solero Microwave Tissue Ablation Applicator (19cm),Solero Microwave Tissue Ablation Applicator (29cm)NEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
April 28, 2017K161596Soft-Vu, Mariner, Accu-Vu and AngioOptic CathetersDQOSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
March 30, 2017K170743AngioDynamics Total Abscession Biliary Drainage CatheterFGESubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
February 21, 2017K170258SpeedLyser Infusion Catheter KitQEYSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
November 16, 2016K162914VenaCure EVLT NeverTouch Procedure KitGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
June 6, 2016K151239NMI DUAL PORT IILJTSubstantially EquivalentNavilyst Medical, Inc.accessdata.fda.gov
December 4, 2015K153228NMI Port, NMI Port IILJTSubstantially EquivalentNavilyst Medical, Inc.accessdata.fda.gov
September 24, 2015K152069Exodus Array Multipurpose Drainage Catheter, Exodus Nuance Nephrostomy Drainage Catheter, Exodus Believe Biliary Drainage CatheterFGESubstantially EquivalentNavilyst Medical, Inc.accessdata.fda.gov
June 18, 2015K150089NanoKnife SystemOABSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
December 11, 2014K142607AngioVac CircuitDWESubstantially EquivalentAngiodynamicsaccessdata.fda.gov
November 12, 2014K142593AngioVac CannulaDWFSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
October 10, 2014K142614AngioDynamics VenaCure EVLT Tre’ Sheath and VenaCure EVLT NeverTouch Procedure KitsGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
September 27, 2013K132713NMI COAXIAL MICROINTRODUCER SETDRESubstantially EquivalentNavilyst Medical, Inc.accessdata.fda.gov
August 8, 2013K131694NMI PORT II CATHETERLJTSubstantially EquivalentNavilyst Medical, Inc.accessdata.fda.gov
March 26, 2013K130671VENACURE EVLT NEVERTOUCH PROCEDURE KITGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
March 30, 2012K112452ANGIODYNAMICS SOFT-VU ANGIOGRAPHIC CATHETERSDQOSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
January 30, 2012K112600ANGIODYNAMICS, INC. VENACURE NEVERTOUCH DIRECT PROCEDURE KITGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
December 15, 2010K102796ANGIODYNAMICS, INC. VENACURE PROCEDURE KITGEXSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
June 17, 2010K101017ANGIODYNAMICS, INC., SMART PORT CT SERIES PORT ACCESS SYSTEMSLJTSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
February 1, 2007K062414VORTEX CT PORT ACCESS SYSTEM AND LIFEGUARD SAFETY INFUSION SETLJTSubstantially EquivalentRita Medical Systems, Inc.accessdata.fda.gov
September 12, 2005K051655ANGIODYNAMICS, INC., MICRO ACCESS KITSDQRSubstantially EquivalentAngioDynamics, Inc.accessdata.fda.gov
December 1, 2004K041957EVLT KIT AND THE D15PLUS AND D30PLUS DIODE LASERSGEXSubstantially EquivalentDiomed, Inc.accessdata.fda.gov
November 18, 2003K033473MODIFICATION TO VORTEX MP VASCULAR ACCESS PORTLJTSubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
September 9, 2003K032557TRIUMPH VTX WITH LIFEVALVE CATHETERLJTSubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
March 29, 2002K013871LIFEGUARD SAFETY INFUSION SETFPASubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
April 10, 2001K010767LIFEPORT VTX ACCESS SYSTEM,MODEL VTX 7000 SERIESLJTSubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
February 12, 2001K010189VORTEX ACCESS SYSTEMLJTSubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
March 13, 1998K974640COAXIAL DILATOR SETDRESubstantially EquivalentBoston Scientific Corpaccessdata.fda.gov
July 2, 1996K961088NON-CORING NEEDLEFMISubstantially EquivalentArrow Intl., Inc.accessdata.fda.gov
January 26, 1996K953529STRATO/INFUSAID LIFE & INFUSE-A-PORT IMPLANTABLE PORT SYSTEMLJTSubstantially EquivalentStrato/Infusaid, Inc.accessdata.fda.gov
August 29, 1995K951814TRIUMPH-1 PORTLJTSubstantially EquivalentHorizon Medical Products, Inc.accessdata.fda.gov
July 7, 1993K915273LIFEPORT ATTACHABLE SYSTEM W/INDUCER KIT LPS 5555LJTUnknownStrato Medical Corp.accessdata.fda.gov
September 23, 1992K921674LIFEPORT INFUSION SET AND INFUSION SET W/ Y SITEFPASubstantially EquivalentStrato Medical Corp.accessdata.fda.gov
April 19, 1991K905852STRATO PLAST PORT INTRO KT(10 FR)LPS 7013/MODIFIEDLJTUnknownStrato Medical Corp.accessdata.fda.gov
April 19, 1991K905850STRATO PLASTIC PORT INTRO(9 FR)LPS 7513/MODIFIEDLJTUnknownStrato Medical Corp.accessdata.fda.gov
April 19, 1991K905849STRATO PLASTIC PORT INTRO KT(10 FR) LPS 7523/MODIFLJTUnknownStrato Medical Corp.accessdata.fda.gov
April 19, 1991K905845STRATO PORT INTRODUCER KT(9 FR) LPS 5513/MODIFIEDLJTUnknownStrato Medical Corp.accessdata.fda.gov
April 19, 1991K905839STRATO PORT INTRODUCER KT(10 FR) LPS 5013/MODIFIEDLJTUnknownStrato Medical Corp.accessdata.fda.gov
April 15, 1991K911355LIFEPORT VASCU ACCESS SYST/PORT INTRO KIT 7015LJTSubstantially EquivalentStrato Medical Corp.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
March 3, 202698463Class IIOngoingSoft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 100CM 035 NB 10SH; Catalog No.: 10707103; Product/UPN No.: H787107071035 (Box), H787107071030 (Pouch); Box Quantity: 10The affected devices contain a manufacturing defect which may prevent the appropriately sized guidewire from passing through the inner diameter (ID) of the catheter hub.accessdata.fda.gov
February 4, 202596192Class IIOngoingIsoLoc Short Profile Prostate Immobilization Treatment Balloon Device Kit; UPN/Catalog Number: ISO-60Product is mislabeled with the incorrect fill volume.accessdata.fda.gov
November 25, 202495640Class IIOngoingAURYON LASER SYSTEM VAC. Model Number: EXM001. Product Number: EXM-2001-1100Potential for procedural delays or interruptions during use of the Auryon Atherectomy System due to the Auryon Atherectomy System not advancing to the Activation (Ready) mode.accessdata.fda.gov
June 18, 202494903Class IIOngoingSOFT-VU KUMPE 5F X 40CM -Used for patients in need of angiographic diagnosis. Catalog Number: 10732702Mislabeled. The shelf-box labeling (unit of sale) is accurate for the packaged devices, however the inner pouch label may contain information for a different model (catheter length)accessdata.fda.gov
May 21, 202494773Class IIOngoingIsoLoc Prostate Immobilization Treatment Balloon Device Kit, Catalog/UPN: ISO-100A single batch of ISO-100 IsoLoc Gas-Release Endorectal Balloons is mislabeled. The affected ISO-100 balloon catheter has a nominal fill volume of 100cc/ml but the inner pouch identifies the product as an ISO-60 (fill volume of 60cc/ml).accessdata.fda.gov
March 18, 202494349Class IIOngoingDURAFLOW 2, 24CM STRAIGHT BASIC KIT -Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012015Tri-Ball Tunneler may contain loosely affixed metal shavings, potential for the metal shaving to embolize, possibly requiring removal via surgical procedure.accessdata.fda.gov
January 30, 202494035Class IIOngoingMINI STICK MAX 4F X 10 CM STD.018 SS/PD ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-749Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath hub, potential risk of the non-conformance is a delay in procedure, wherein the user may need to exchange the sheath toaccessdata.fda.gov
December 18, 202393744Class IIOngoingPulseSpray Infusion System devices including: PULSE SPRAY 5F/135/20, UPN: H787125004045, REF: 12500404; Pulse Spray 3Fx135x20, UPN: H787125004155, REF: 12500415; and PULSE SPRAY 5F/45/10, UPN: H787125004235, REF: 1250042Rotating adaptor O-ring manufacturing defect impacting seal integrity which may lead to a leak during infusion of medication.accessdata.fda.gov
March 2, 202391909Class IIOngoingNanoKnife 5-Probe Procedure Pack 15 cm - Activation. Indicated for the surgical ablation of soft tissue. Catalog Number: 20400111 UPN: H787204001110Not programmed in accordance with specification. The programming affects the RFID function and does not allow the NanoKnife probes to be recognized by the NanoKnife generator resulting in a delay in procedureaccessdata.fda.gov
September 20, 202290924Class IIOngoingVortex MP Port Titanium Low Profile Implanted Port with 5F attached Silicone Catheter and Tray. Indicated for central venous placement (either peripheral or chest placement) when patient therapy requires repeated venous Printed Instructions for Use (IFU) not shipped with device. The Instructions for Use contain the Warnings, Precautions, Contraindications, and Procedures for the Preparation, Implantation, and Post Operative Care of the implantable port, failure to follow the Instructions for Use may result in patient injury.accessdata.fda.gov
August 10, 202290811Class IIOngoingVenaCure EVLT KIT WITH SPOTLIGHT OPS SHEATH 55CM Ref./ Catalog No.: EVLT55OPS (each box contains 5 Procedure Kits). For use in the treatment of varicose veins.OPS Fiber packaged within specific VenaCure EVLT Procedure Kits does not meet the required dimensional specification, may result in damage to the sheath, including separation or the inability to move the fiber within the sheath. A damaged sheath will necessitate removal from the patient, which may result in procedural delay and/or surgical interventionaccessdata.fda.gov
July 20, 202188444Class IITerminatedSolero Generator Refurbished US PG, Item No. H78712740000USD0, Catalog No. 12740000USDSpecific serial numbers of the Solero MTA Generator require servicing to upgrade the software to help reduce the incidence of Error 0001, which can occur during system start-up.accessdata.fda.gov
October 14, 202086627Class IITerminatedAngiodynamics 5F Standard Micro-Introducer Kit - indicated for percutaneous introduction of a guidewire or catheter into the vascular system, Catalog Number: 06597035 UPN: H7870659703555F Micro-Introducer Kits may not contain the correct device, packaged with a 4F Sheath/Dilator componentaccessdata.fda.gov
May 4, 202085631Class IITerminatedBioFlo Midline Catheter and BioFlo Maximal Barrier Kits - Product Usage: These introducers are used for the percutaneous introduction of diagnostic or therapeutic devices, such as catheters or pacing leads in the vasculaCertain AngioDynamics PICC Kits contain BD PosiFlush SF Saline Flush Syringes which were recalled by BD Medical on April 16, 2020.accessdata.fda.gov
April 24, 202088679Class IITerminatedAngioDynamics NanoKnife Disposable Single Electrode Probes, Irreversible Electroporation (IRE) Device, 15 cm IRE Single Electrode RFID Activation, PG. Catalog No. 20400103Programming issue affected RFID function of a single lot and did not allow the NanoKnife probes to be recognized by the NanoKnife generator.accessdata.fda.gov
November 19, 201984382Class IITerminatedOARTRAC PROSTATE IMMOBILIZATION ENDORECTAL BALLOON DEVICE KIT, Catalog Number: ORB-60F - Product Usage: pre-calibrated PSD sensors are intended for use during cancer treatments to measure photon and electron radiation thMay result in readings outside of the expected accuracy range.accessdata.fda.gov
June 27, 201983334Class IITerminatedAngioDynamics VenaCure EVLT NeverTouch Procedure Kit, 45CM NEVERTOUCH FRS.018 PROCEDURE KIT PG, Catalog Number 11403012The affected product is properly labelled with an expiration date of March 31, 2022; but the RFID programmed expiration date is April-2014 which results in an error message when connected to the laser source and prevents the product from being used.accessdata.fda.gov
September 22, 201779193Class IITerminatedSoft-Vu Omni Flush Angiographic Catheter (UPN H787107322015); SV OF 5F x 65 cm.035 NB PG; Catalog Number: 10732201 AngioDynamics Angiographic Catheters are for use where angiographic diagnosis is indicated.Product was placed into distribution prior to completion of all required post sterilization release activities.accessdata.fda.gov
June 5, 201777631Class IITerminatedAccu2i pMTA Applicator, 14 cm STANDARD, REF/Catalog #, Model # (UPN) H7879006000, STERILE --- This is only for use with a Sulis V Generator, REF 806-10. Product Usage: The Acculis Accu2i pMTA Microwave Tissue Ablation ApThe firm is recalling product that has the potential to not function during use. The product affected by this recall will not deliver the desired microwave energy due to coolant ingress in an electrical connection; this condition results in an error code High Reflective Power displayed on the microwave generator.accessdata.fda.gov
September 28, 201675420Class IITerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 5 F Stiffened Micro-Introducer Kit, 45CM SS/SS ECHO B PG, Item Number H787065970395, Catalog No.REF 06597039, 2) 5 F Stiffened Micro-Introducer KitGreatbatch Medical the manufacturer of the 4F and 5F sheath/dilator components has determined that the products listed in their September 7, 2016 Recall Notification have the potential for the rotating luer to detach from the dilator hub during use. AngioDynamics has confirmed that affected sheath/dilators (Greatbatch Model Numbers 10904-001 and 10904-002) haccessdata.fda.gov
August 6, 201468980Class IITerminatedUni*Fuse INFUSION SYSTEM WITH COOPER WIRE, 5F x 90 cm x 10 cm Infusion Pattern, Catalog No./REF 12401806, Product No. H787124018065, STERILE -- AngioDynamics, 603 Queensbury Avenue, Queensbury, NY 12804AngioDynamics became aware that Uni*Fuse Infusion Systems with Cooper Wire have the potential to contain an incorrect sized guidewire (too long).accessdata.fda.gov
April 30, 201365119Class IITerminatedAngioDynamics Micro Introducer Kits under the following labeling: 1) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597005, 2) AngioDynamics 5F Standard Micro-Introducer Kit, Sterile, Catalog AngioDynamics Inc., is recalling Micro Introducer Kits and VenaCure EVLT NeverTouch Procedure Kits, because the potential exists that the micro Introducer (sheath/dilator) packaged within the kit could be the incorrect French size.accessdata.fda.gov
April 4, 201159825Not yet classifiedTerminatedANGIODYNAMICS NANOKNIFE IRE GENERATOR, Catalog/REF No. 20300101, ANGIODYNAMICS, 603 Queensbury Ave., Queensbury, NY 12804 Intended to remove tissue and control bleeding by the use of high- frequency electrical current (sSome units of Nanoknife have the potential to deliver a shortened pulse width without indicating an error. The affected units contain a "GOMe" circuit board which may cause the generator to drift from the calibration points set at the time of manufacture.accessdata.fda.gov
January 24, 201159833Not yet classifiedTerminatedDURAMAX 15.5 F x 22 cm Chronic Hemodialysis Catheter Set (With Cuff 17 cm from Tip), DuraMax Stacked Tip 22 cm Str. Basic Kit, Catalog No./REF 10302802, STERILE --- AngioDynamics, Inc. 603 Queensbury, NY USA 12804. The AAngioDynamics received customer complaints for breakage of the tunneler sleeve during product use.accessdata.fda.gov
May 17, 201055715Not yet classifiedTerminatedPULSESPRAY INFUSION SYSTEM, 90 cm x 20 cm infusion length, Catalog No./Ref 12500402, STERILE, EO. AngioDynamics, 603 Queensbury Avenue, Queensbury, NY 12804. Infusion Catheter.This lot was packaged with the wrong occluding ball guidewire. The PulseSpray Catheter is 90 cm in length and requires a 109 cm occluding ball guidewire, however this lot was packaged with a 60 cm occluding ball guidewire.accessdata.fda.gov
April 30, 201055713Not yet classifiedTerminatedANGIODYNAMICS BENEPHIT(TM) XT Infusion System, 35 cm, Targeted Renal Therapy Infusion system, Model/REF Number 70035, STERILE, EO, Intended for Single Use Only. AngioDynamics, Incorporated 603 Queensbury, NY 12804.Benephit Infusion Catheters may exhibit a hole or tear in the primary sterile barrier packaging. The product is intended to be sterile. Breaches in the sterile packaging may result in non-sterile product, which could potentially cause a patient infection which is a serious medical condition.accessdata.fda.gov
January 8, 201055701Not yet classifiedTerminatedDURAMAX (TM) Hemodialysis Catheters, Stacked Tip 22 cm Straight Basic Kit, Catalog Number/REF 10302802, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804The product has the potential for a cross-lumen leak. One of the two leak testers that are used to perform the leak test on the DuraMax Catheters was found to be faulty. The tester was not able to detect cross-lumen leaks. Both testers were used during the manufacturing 100% leak test.accessdata.fda.gov
July 7, 200849042Not yet classifiedTerminatedCentros(TM) 15F x 24cm Chronic Hemodialysis Curved Catheter Set (With Cuff 19cm From Tip), Catalog No./REF 10303101. Sterile. Manufactured for AngioDynamics, Inc. MANUFACTURED IN USA. ANGIODYNAMICS, INC. Queensbury, NY UThe cuff may be inadequately attached to the catheter, resulting in possible catheter movement or leakage at the insertion site.accessdata.fda.gov

Compare with other makers

Updated April 17, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.