Skip to the page

Data / Medical devices / United States / Alpha-Omega Services, Inc.

Alpha-Omega Services, Inc.: FDA-registered device maker in Bellflower, CA, United States, 3 510(k) clearances

Alpha-Omega Services, Inc. is registered with the FDA (registration 2022694) in Bellflower, CA, United States. It lists 2 device types. The FDA files 3 510(k) clearances under its listings, the newest dated July 10, 2024. 3 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2022694
Address
9156 Rose ST, Bellflower, CA, United States, 90706
Owner or operator
ALPHA-OMEGA SERVICES (2022694)
Roles
Complaint file establishment, Manufacturer
First device listed
November 29, 2007
Registered through
2026
Brand names listed
AOS Interstitial Templates, Needles, and Accessories, AOS Marker Seeds, Universal Connecting Guide Tube

Devices it lists

DeviceProduct codeClassRoleSource
Source, Brachytherapy, RadionuclideKXK2Complaint file establishment, Manufactureraccessdata.fda.gov
System, Applicator, Radionuclide, Remote-ControlledJAQ2Complaint file establishment, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
July 10, 2024K233628AOS Interstitial Templates, Needles, and AccessoriesJAQSubstantially EquivalentAlpha-Omega Services, Inc.accessdata.fda.gov
July 2, 2024K233626AOS Marker Seeds (SMG0242-025)JAQSubstantially EquivalentAlpha-Omega Services, Inc.accessdata.fda.gov
March 10, 1997K964910AOS UNIVERSAL CONNECTING GUIDE TUBE FOR HIGH DOSE RATE AFTERLOADERSJAQSubstantially EquivalentAlpha-Omega Services, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
November 15, 200749128Not yet classifiedTerminatedAlpha-Omega Services, Inc. Product No: NFV0001-004 Description: NEEDLE, FLEXIGUIDE: SERIES-15, 25CM, WITH FEMALE LUER ADAPTOR, SHARP AND STYLET WITH MALE LUER ADAPTOR (HDR); 10/PKG Quantity: 10/PKG L-NFV0001-004. The FleThere is a possibility that the Flexiguide Needle tip is defective. There is the potential for the needles tip to leak, thereby breaking the sterile boundary and possibly contaminating other devices with body fluids.accessdata.fda.gov
February 21, 200634969Not yet classifiedTerminatedTII0002 Implant Tube, Implant Tube, Intralumenal(HDR), 10CM Drawdown 130CM Body, Sealed End, Cable Insert & Gold Seed, DisposableThere is a possibility that the diameter of the catheter does not meet specifications. As a result it may not be possible to correctly connect the catheter to a VariSource Quick Connect. This would prevent any treatment. Furthermore, since the problem would not be apparent until after the catheter has been implanted an unnecessary surgical implantation proceaccessdata.fda.gov
September 4, 200327709Not yet classifiedTerminatedTemplate Needle, Series 17, 20 cm, with Threaded Female hub and Bent Stylet, Closed-End, Disposable. Packaged in single, 10, 15, 20 per package.Template needle may fracture leaving tip in patient.accessdata.fda.gov

Compare with other makers

Updated July 10, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.