Advanced Sterilization Products: FDA-registered device maker in Irvine, CA, United States, 40 510(k) clearances

Advanced Sterilization Products is registered with the FDA (registration 2084725) in Irvine, CA, United States. It lists 15 device types. The FDA files 40 510(k) clearances under its listings, the newest dated January 29, 2026. 47 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2084725
FEI number
3003662624
Address
33 Technology Drive, Irvine, CA, United States, 92618
Owner or operator
Advanced Sterilization Products (9068155)
Roles
Complaint file establishment, Manufacturer, Remanufacturer, Repackager or relabeler, Specification developer
First device listed
July 8, 1999
Registered through
2026
Brand names listed
AEROFLEX AER, AUTOSURE MRC Reagent, AEROZYME and AERO-OPA (28000, 23300, 25520, 25410), APTIMAX Instrument Tray Holders (994XX), APTIMAX Instrument Tray for ULTRA GI Cycle (011077), ASP ACCESS (53001), Aptimax Instrument Tray (138XX), CIDEX OPA Test Strips (20392, 20393), CIDEX OPA Test Strips (2927), CIDEX™ OPA Concentrate (20398) and more

Devices it lists

DeviceProduct codeClassRoleSource
Accessories, Cleaning, For EndoscopeFEB2Complaint file establishment, Specification developeraccessdata.fda.gov
Bath, Incubators/Water, AllJTQ1Specification developeraccessdata.fda.gov
Cleaner, Ultrasonic, Medical InstrumentFLG1Complaint file establishment, Specification developeraccessdata.fda.gov
Indicator, Biological Sterilization ProcessFRC2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Indicator, Physical/Chemical Sterilization ProcessJOJ2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Medical Device Data SystemOUG1Specification developeraccessdata.fda.gov
Sterilant, Medical DevicesMED2Complaint file establishment, Specification developeraccessdata.fda.gov
Sterilization Wrap Containers, Trays, Cassettes & Other AccessoriesKCT2Complaint file establishment, Specification developeraccessdata.fda.gov
Sterilizer, ChemicalMLR2Complaint file establishment, Manufacturer, Remanufacturer, Repackager or relabeler, Specification developeraccessdata.fda.gov
Sterilizer, Ethylene-Oxide GasFLF2Manufactureraccessdata.fda.gov
Table, MechanicalINW1Specification developeraccessdata.fda.gov
Tray, SurgicalLRP1Specification developeraccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Specification developeraccessdata.fda.gov
Ultraviolet Radiation Disinfection Chamber DeviceSCS2Complaint file establishmentaccessdata.fda.gov
Wrap, SterilizationFRG2Complaint file establishment, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
January 29, 2026K251354UV Smart D60SCSSubstantially EquivalentUV Smart Technologies B.V.accessdata.fda.gov
July 5, 2024K234084STERRAD™ Chemical Indicator (CI) Strip (14100); STERRAD® SEALSURE® Chemical Indicator (CI) Tape (14202NL); STERRAD VELOCITY™ Biological Indicator (BI) (43210) (60 count); STERRAD VELOCITY™ Biological Indicator (BI) (43210-30)(30 count); STERRAD VELOCITY™ Reader (43220); ULTRA GI™ Process Challenge Device (PCD) (43400)(30 count)JOJSubstantially EquivalentAdvanced Sterilization Products, Inc.accessdata.fda.gov
July 5, 2024K234082STERRAD® 100NX Sterilizer with ALLClear™ Technology and ULTRA GI™ Cycle (10104); APTIMAX™ Instrument Tray for ULTRA GI™ Cycle (011077)MLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
May 16, 2022K220404STERRAD NX with ALLClear TechnologyMLRSubstantially EquivalentAdvanced Sterilization Products, Inc.accessdata.fda.gov
October 9, 2021K212174STERRAD 100NX Sterilizer with ALLClear TechnologyMLRSubstantially EquivalentAdvanced Sterilization Products, Inc.accessdata.fda.gov
January 23, 2020K192025STERRAD VELOCITY Biological Indicator/Process Challenge Device and ReaderFRCSubstantially EquivalentAdvanced Sterilization Products (Asp)accessdata.fda.gov
April 23, 2019K181472AEROFLEX(TM) Automatic Endoscope Reprocessor with AUTOSURE(TM) MRC MonitorFEBSubstantially EquivalentAdvanced Sterilization Products (Asp)accessdata.fda.gov
December 27, 2018K182404STERRAD VELOCITY Biological IndicatorFRCSubstantially EquivalentAdvanced Sterilization Products (Asp)accessdata.fda.gov
July 31, 2017K163598Tyvek Self-Seal Pouches with STERRAD Chemical Indicator, Tyvek Rolls with STERRAD Chemical Indicator, Tyvek Heat-Seal Pouches with STERRAD Chemical IndicatorKCTSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
June 20, 2017K170039STERRAD VELOCITY Biological Indictator and ReaderFRCSubstantially EquivalentAdvanced Sterilization Products (Asp)accessdata.fda.gov
September 27, 2016K160818STERRAD® NX Sterilizer with ALLClear™ TechnologyMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
September 26, 2016K160903STERRAD 100NX Sterilizer with ALLClearTM TechnologyMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
July 20, 2016K152189EVOTECH ECRFEBSubstantially EquivalentAdvanced Sterilization Products (Asp)accessdata.fda.gov
April 3, 2015K142454STERRAD NX Sterilizer, STERRAD 100NX SterilizerMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
December 22, 2014K140977EVOTECH ECRFEBSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
December 19, 2014K141693Tyvek® Pouch/Roll with STERRAD® Chemical IndicatorFRGSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
October 15, 2012K112087TYVEK SELF-SEAL POUCHES ,TYVEK HEAT-SEAL ROLLSKCTSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
October 3, 2012K111519STERRAD SEALSURE CHEMICAL INDICATOR TAPE MODEL 14202JOJSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
October 3, 2012K111518STERRAD CHEMIAL INDICATOR STRIP MODEL 14100JOJSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
September 13, 2012K111377STERRAD(R) 100NX STERILIZER DUO CYCLEMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
June 6, 2011K103210TYVEK SELF-SEAL POUCHES WITH STERRAD, TYVEK ROLLS WITH STERRAD, TYVEK HEAT-SEAL WITH STERRAD CHEMICAL INDICATORSFRGSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 1, 2011K103219STERRAD SEALSURE CHEMICAL INDICATOR TAPEJOJSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 1, 2011K103218STERRAD CHEMICAL INDICATOR STRIPJOJSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
March 4, 2011K092622STERRAD 100NX STERILIZER EXPRESS CYCLEMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
February 25, 2011K092755STERRAAD 100NX EXPRESS CYCLE TEST PACKFRCSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
November 13, 2008K082392EVOTECH ENDOSCOPE CLEANER AND REPROCESSORFEBSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
June 11, 2008K081427BROWNE OPA TEST STRIPJOJSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
December 18, 2007K071537STERRAD 100NX TEST PACKFRCSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
November 29, 2007K071385STERRAD 100NX STERILIZERMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
May 12, 2005K042450STERRAD NX CHALLENGE PACKFRCSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 22, 2005K042116STERRAD NX STERILIZERMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 4, 2005K032959CIDEX OPA CONCENTRATEMEDSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 2, 2004K040742MODIFICATION TO STERRAD SEALSURE CHEMICAL INDICATOR TAPEJOJSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
April 3, 2003K023290STERRAD 50 & STERRAD 100S STERILIZERSFLFSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
February 27, 2003K0300040.55% ORTH-PHTHALALDEHYDE SOLUTIONMEDSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
August 28, 2002K013003APTIMAX INSTRUMENT TRAY, INSTRUMENT MAT AND INSTRUMENT HOLDERFRGSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
June 15, 2000K991999STERRAD 100S STERILIZERMLRSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
December 7, 1998K981054BROWNE GA INDICATOR FOR CIDEX PRODUCTSJOJSubstantially EquivalentAlbert Browne , Ltd.accessdata.fda.gov
May 19, 1995K951295STERRAD STERILIZATION POUCHKCTSubstantially EquivalentAdvanced Sterilization Productsaccessdata.fda.gov
October 4, 1993K921910STERRAD CHEMICAL INDICATORJOJSubstantially EquivalentJohnson & Johnson Medical, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
January 9, 201776194Class IITerminatedSTERRAD NX Sterilization System, Product Code: 10033, 10033-002Advanced Sterilization Products (ASP) has identified that in a rare sequence of events following an external power outage, the system door interlock can be become disengaged during system reboot for a 20-second duration.accessdata.fda.gov
September 27, 201675290Class IITerminatedEVOTECH Endoscope Cleaner and Reprocessor System 208V, Product Code: 50004 The EVOTECH ECR Endoscope Cleaner and Reprocessor, a washer/disinfector, is indicated for use with high-level disinfectant CIDEX OPA Concentrate Advanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor System because the hose may come loose and cause a leak.accessdata.fda.gov
August 10, 201571887Class IITerminatedCIDEX OPA Solution, P/N 20390 for use as a high level disinfectant for reprocessing heat sensitive medical devices.Advanced Sterilization Products (ASP) is reminding all CIDEX OPA Solution customers to follow the warnings and rinsing procedure in their current labelling around the criticality of proper rinsing of medical device following disinfection with CIDEX OPA according to the CIDEX OPA Solution IFU (Instruction For Use).accessdata.fda.gov
July 27, 201571708Class IITerminatedCIDEX Activated Dialdehyde Solution, 4 bottles/case, P/N: 2266Advanced Sterilization Products (ASP) is recalling the CIDEX Activated Dialdehyde Solution because it may lack the adequate data to support the entire 24-month shelf life.accessdata.fda.gov
July 17, 201571642Class IITerminatedWall Chart for STERRAD 100NX System, P/N 10104. The STERRAD 100NX Sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures.Advanced Sterilization PRoducts (ASP) is recalling the Wall Chart for STERRAD 100NX System because it incorrectly states "APTIMAX Instrument Trays can be enclosed in either polypropylene wrap or in Tyvek Pouches with STERRAD Chemical Indicators."accessdata.fda.gov
May 11, 201571209Class IITerminatedEVOTECH Endoscope Cleaner and Reprocessing System 208V, P/N 50004. The ASP EVOTECH ECR Endoscope Cleaner and Reprocessor is a washer/disinfector, which is indicated for use with high-level disinfectant CIDEX OPA ConcentrAdvanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor (ECR) because it may not detect an improper endoscope connection on two channels, and subsequently pass the cycle without cancellation if there is a disconnected scope.accessdata.fda.gov
December 24, 201470216Class IITerminatedTyvek Pouch/Roll with STERRAD Chemical Indicator, P/N 12425Advanced Sterilization Products (ASP) is recalling the Tyvek Rolls with STERRAD Chemical Indicator because they were shipped to customers after its expiration date of May 18, 2013.accessdata.fda.gov
November 4, 201469692Class IITerminatedSTERRAD 50, Product Code 10114. The STERRAD Cassettes are used on STERRAD Sterilization System which is a low temperature general purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.Advanced Sterilization Products is recalling the STERRAD System cassettes because the the leak indicator on the STERRAD System cassettes packaging may not function properly after exposure to hydrogen peroxide.accessdata.fda.gov
December 16, 201367043Class IITerminatedSTERRAD NX Sterilization System, Product Code: 10033 The STERRAD NX Sterilization System is a general purpose, low temperature sterilizer which uses the STERRAD NX process to inactivate microorganisms on a broad range ofAdvanced Sterilization Products (ASP) is recalling the STERRAD NX, STERRAD 50, and STERRAD 100S Sterilization Systems because some healthcare workers detected odors or smells possibly emanating from STERRAD Systems.accessdata.fda.gov
November 26, 201366981Class IITerminatedSTERRAD Cyclesure Biological Indicator (BI, Part No. 14324. Intended to be used as a standard method for frequent monitoring of the STERRAD Sterilization System cycles.Advanced Sterilization Products (ASP) is recalling the STERRAD Cyclesure Biological Indicator (BI) because ASP has identified a microscopic intermittent and low frequency flaw in the outer vial of the STERRAD Cyclesure 24 Biological Indicator.accessdata.fda.gov
November 11, 201366815Class IITerminatedSTERRAD 100NX, Product Code: 10104 The STERRAD Steri lization System is a low temperature general purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.Advanced Sterilization Products (ASP) is recalling the STERRAD NX and STERRAD 100NX sterilization systems because ASP has determined that the bronchoscopes may contain a polyurethane material in the suction channel location that is not listed in the current claims for interior channels (lumens) for processing in STERRAD systems.accessdata.fda.gov
October 18, 201366546Class IITerminatedSterrad 100NX, Product Code: 10104. Used to sterilize heat and moisture sensitive reusable medical devices.Advanced Sterilization Products (ASP) is recalling the Sterrad 100NX Sterilizer some healthcare workers detected odors/smells emanating from the 100NX Sterilizers, and it may be related to normal breakdown of the oil used in the Sterrad 200 vacuum pumps.accessdata.fda.gov
October 3, 201366502Class IIITerminatedSTERITITE Containers: STERITITE Container Kit, 1/4 size, 3" high, product code: 13902; STERITITE Mini Mid Size, 3" high, product code: 13903; STERITITE Container Kit, 1/2 size, 4" high, product code: 13904; STERITITE ConAdvanced Sterilization Products (ASP) is recalling the SteriTite containers because they do not have consistent data to show that sterility assurance level of 10(-6) is achieved during the half-cycle test runs on new, unprocessed containers.accessdata.fda.gov
September 18, 201366328Class IITerminatedSTERRAD 200 Sterilizer (Single Door), Part Number: 10201. STERRAD 200 Sterilizer (Double Door), Part Number: 10202. The STERRAD Sterilization System is a low temperature general purpose sterilizer used to sterilize heat Advanced Sterilization Products (ASP) is recalling the STERRAD 200 Sterilization System because it may emit an odor or smell into the surrounding environment that is not typical to normal operating conditions.accessdata.fda.gov
September 18, 201366317Class IITerminatedSTERRAD 100NX Cassettes The STERRAD Sterilization System is a low temperature general purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.Advanced Sterilization Products (ASP) is recalling the three lots (13F049, 13F050, 13F051) STERRAD 100NX Cassettes because ASP has determined that the leak indicator on the cassettes is effective for only 12 months of the cassette's labeled 15-month shelf-life.accessdata.fda.gov
July 25, 201365957Class IITerminatedSTERRAD 100NX Cassettes, Product Code: 10144 The STERRAD Sterilization System is a low temperature general purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.The recall of the STERRAD 100NX Cassettes was initiated because Advanced Sterilization Products (ASP) does not have adequate data to support the effectiveness of the packaging's leak indicator for the entire duration of the STERRAD 100 NX System cassette's 15 month shelf life.accessdata.fda.gov
April 22, 201364972Class IITerminatedSTERRAD CYCLESURE 24 Biological Indicator (BI) The STERRAD CYCLESURE 24 Biological Indicator (BI), is intended to be used as a standard method for frequent monitoring of the STERRAD Sterilization System cycles.Advanced Sterilization Products is recalling certain lots of STERRAD CYCLESURE 24 Biological Indicator product because it may not have adequate data to support the entire duration of the labeled shelf-life.accessdata.fda.gov
March 28, 201364781Class IITerminatedEVOTECH Endoscope Cleaner and Reprocessor System, P/N 50004. Designed to automatically clean and high-level disinfect flexible, submersible video or fiber-optic endoscopes.Advanced Sterilization Products (ASP) is recalling the EVOTECH Endoscope Cleaner and Reprocessor (ECR) because they have received reports of smoke emanating from the system due to a circuit board malfunction that may occur in the Channel Control Manifold sub-assembly.accessdata.fda.gov
March 22, 201364700Class IITerminatedEVOTECH Endoscope Cleaner & Reprocessor System, P/N 50004 Designed to automatically clean and high-level disinfect flexible, submersible video or fiber-optic endoscopes.Advanced Sterilization Products (ASP) has determined that a limited number of EVOTECH ECRs manufactured between 2011 and 2012 did not receive sufficient High Potential (HIPOT) DC voltage testing.accessdata.fda.gov
March 22, 201364692Class IITerminatedSTERRAD 100NX Sterilization System, P/N 10104 Product Usage: The STERRAD 100NX Sterilization System is a general purpose, low temperature sterilizer which uses the STERRAD 100NX process to inactivate microorganisms on a The recall was initiated because Advanced Sterilization Products (ASP) has determined that the STERRAD 100NX and STERRAD 200 Sterilization Systems may emit an odor or smell into the surrounding environment that is not typical to normal operating conditions.accessdata.fda.gov
October 3, 201263758Class IITerminatedSTERRAD CYCLESURE 24 Biological Indicator (BI) product, P/N 14324. Validation kits with Sterrad Cyclesure 24 BI products: Codes/Serial Numbers, Product Description: 14324 Sterrad Cyclesure 24 Biological Indicator. 14324-Advanced Sterilization Products (ASP) is recalling all lots of Sterrad Cyclesure 24 Biological Indicator (BI) manufactured between February 2008 and December 2011 because it may not have adequate data to support the entire duration of the labeled shelf-life.accessdata.fda.gov
September 20, 201263877Class IITerminatedSTERRAD NX Cassettes, P/N 10133. The STERRAD NX sterilizations systems are low-temperature general purpose sterilizers used to sterilize heat and moisture sensitive reusable medical devices. The sterilant used is hydrogeAdvanced Sterilization Products is recalling three lots of STERRAD NX System Cassettes because it does not have adequate data to support the entire duration of the product's labeled shelf-life.accessdata.fda.gov
June 28, 201233854Class IITerminatedSTERRAD Cyclesure Biological Indicator (BI), P/N 14324 are sold in cases, packaged as part of STERRAD System Validation kits and STERRAD test packs. The STERRAD CYCLESURE 24 Biological Indicator (BI), P/N 14324 is intendAdvanced Sterilization Products (ASP) is recalling certain lots of the STERRAD CYCLESURE 24 Biological Indicator (BI) product because it does not have adequate data to support the entire duration of the product's labeled shelf-life.accessdata.fda.gov
June 19, 201262925Class IIITerminatedSTERRAD 100S Cassette, Batch # 12A077. The STERRAD 100S and STERRAD NX sterilizations systems are low-temperature general purpose sterilizers used to sterilize heat and moisture sensitive reusable medical devices. The stAdvanced Sterilization Products (ASP) is recalling (removing) the Sterrad 100S and Sterrad NX System cassettes because the camera used to verify printing on the Sterrad System cassettes was inadvertently disabled. The STERRAD 100S and STERRAD NX System cases were shipped without verification of proper printing.accessdata.fda.gov
June 1, 201262919Class IITerminatedCIDEX OPA, High Level Disinfectant Solution, Glutaraldehyde-free (0.55% ortho-phthaladehyde) solution. The CIDEX OPA solution is intended for automated and manual cleaning and disinfection.The recall was initiated because Advanced Sterilization Products has discovered instances of missing labels on bottles of CIDEX OPA Solution, Part # 20390 manufactured between May 2011 and April 2012.accessdata.fda.gov
March 13, 201264609Class IITerminatedSTERRAD 200 System Carriage, P/N 10208. Used as a tool to expedite loading and unloading processed items from a STERRAD 200 sterilizer.Advanced Sterilization Products (ASP) is recalling the STERRAD 200 System Carriage because it can potentially become dislodged when an excessive load is applied.accessdata.fda.gov
February 17, 201261954Not yet classifiedTerminatedSterrad Cyclesure 24 Biological Indicator, P/N: 14324 The STERRAD CYCLESURE 24 Biological Indicator is intended to be used as a standard method for frequent monitoring of the STERRAD Sterilization System cycles.The recall was initiated by Advanced Sterilization Products because they recently determined that certain lots of raw materials that were rejected during incoming inspection acceptance test were used for the manufacture of a specific lot range of Sterrad Cyclesure 24 Biological Indicator.accessdata.fda.gov
January 23, 201260889Not yet classifiedTerminatedSTERRAD 200 Sterilizer, Hydrogen Peroxide Gas Plasma Sterilizer, Chemical Sterilizer. STERRAD 200; Product Usage: The STERRAD Sterilization System is a low-temperature general-purpose sterilizer used to sterilize heat anASP determined that an internal filter in the vacuum pump on the STERRAD 200 System is subject to wear over time.accessdata.fda.gov
June 23, 201056367Not yet classifiedTerminatedTyvek Self-Seal Pouch with STERRAD Chemical Indicator 12332. Intended to be used to contain medical devices that are being terminally sterilized in STERRAD Sterilization Systems.The recall was initiated after Advanced Sterilization Products (ASP) discovered a non-conforming lot. The misaligned perforations may have caused the seal to be incomplete on some of the pouches, creating a potential breach for pouches being used to store sterilized equipment on shelves.accessdata.fda.gov
February 19, 201057281Not yet classifiedTerminatedASP Automatic Endoscope Reprocessor (AER), Product Code: 20300 & 20301 The AER is a machine designed to automatically wash and high-level disinfect flexible, submersible fiberoptic or video endoscopes.The recall was initiated because Advanced Sterilization Products (ASP) received three customer reports of elevated temperature of the high-level disinfectant solution used in the ASP AER as a result of a possible temperature monitoring system malfunction. This recall communication advised consignees that if high-level disinfectants are exposed to elevated teaccessdata.fda.gov
June 23, 200952632Not yet classifiedTerminatedSterrad CycleSure Biological Indicator, Product Code 14324. The Sterrad CycleSure Biological Indicator is intended to be used as a standard method for frequent monitoring of the Sterrad Sterilizer cycles.Biological Indicator indicating a positive result does not maintain yellow color for the entire incubation period and some indicators experience media evaporation prior to the end of the labeled maximum incubation time.accessdata.fda.gov
March 9, 200951413Not yet classifiedTerminatedSTERRAD 50 Sterilization System Product Code 10050 The STERRAD Sterilization System is a low-temperature general-purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.ASP has identified a secondary, lower-occurring cause of oil mist within certain STERRAD NX Systems and STERRAD 50 Systems due to potentially defective oil fill plugs.accessdata.fda.gov
January 12, 200952124Not yet classifiedTerminatedSterrad 50 Sterilizer, Product Code 10050. Low-temperature general-purpose sterilizer used to sterilize heat and moisture sensitive reusable medical devices.The capacitor in the vacuum pump component within the Sterrad 50 System could overheat and potentially create a hazardous condition inside the system, resulting in smoke and/or fire.accessdata.fda.gov
December 10, 200851146Not yet classifiedTerminatedSTERRAD NX Sterilizer Hydrogen Peroxide Gas Plasma Sterilizer Product Code 10133. The STERRAD Sterilization System is a low-temperature general-purpose sterilizer used to sterilize heat and moisture sensitive reusable meAdvanced Sterilization Products (ASP) has discovered a defect in the barcode labeling of the STERRAD NX System Cassettes 10133, Lot #08I032. This is the only lot number affected by this action. The barcodes for Lot #08I032 were printed improperly and are not capable of being read by the STERRAD unit.accessdata.fda.gov
October 17, 200850073Not yet classifiedTerminatedSTERRAD 100S Sterilizer (Product Code 10101). The sterilizer includes software and hardware components. The STERRAD Sterilization System is a low-temperature, general purpose sterilizer used to sterilize heat and moistur1) Inability of the sterilizer to detect when an injection takes place without hydrogen peroxide being transferred to the vaporizer bowl. This situation can result in a cycle completion with the injection of insufficient hydrogen peroxide sterilant and 2) Inability of the sterilizer to detect an obstruction in the door travel path while the door is closing. accessdata.fda.gov
October 7, 200850071Not yet classifiedTerminatedSTERRAD NX Sterilizer, Product Code 10033 Low temperature sterilizers that use hydrogen peroxide gas plasma to inactivate microorganisms on a broad range of medical and surgical instruments.ASP has discovered a component defect in some of the UV lamp power supplies used in certain STERRAD NX Sterilizers. This defect can potentially cause the Hydrogen Peroxide Monitor to give inaccurate readings.accessdata.fda.gov
September 11, 200849451Not yet classifiedTerminatedASP Automatic Endoscope Reprocessor, AER Plus Product Code 20300 and AER with printer Product Code 20301 The AER is a machine designed to automatically wash and high-level disinfect flexible, submersible fiberoptic or viResidual high-level disinfectant solution remaining in endoscopes that have been reprocessed in the ASP Automatic Endoscope Reprocessor. If high-level disinfectant, or other fluids, remains in the endoscope after reprocessing, contact with the mucous membranes may occur and result in chemical burns, irritation (chemical colitis), or other symptoms.accessdata.fda.gov
February 25, 200847355Not yet classifiedTerminatedSTERRAD 100S Sterilization System, Product Code 10101 Used to sterilize heat and moisture sensitive reusable medical devices.Oil mist filter fails allowing oil mist to be emitted into the vicinity of the sterilizer, which may result in the release of a mist, "haze," or "smoke."accessdata.fda.gov
February 13, 200846906Not yet classifiedTerminatedEvoTech Endoscope Cleaner & Reprocessor, Product Code 50004 Indicated for use with high level disinfectant CIDEX OPA Concentrate and an enzymatic detergent, CIDEZYME GI, to achieve cleaning and high level disinfection ofCleaning cycles are being cancelled. Specific issues are: a) Water heater tank is rusting resulting in the in-line 0.2 micron filter prematurely clogging, b) Interface board malfunction resulting in a premature lid opening, and c) Minor fluid leaks within the system (commonly at the 0.2 micron filter attachment points).accessdata.fda.gov
November 12, 200745851Not yet classifiedTerminatedSTERRAD 100S Sterilizer, Product Code: 10101, Advanced Sterilization Products, Irvine, CAUser Guide Update: based on user reports about contact with residual hydrogen peroxide from instruments, pouches and trays after sterilization and subsequent light colored residue on these devices after sterilization updated user guidance has been issued.accessdata.fda.gov
November 12, 200745846Not yet classifiedTerminatedSTERRAD Sterilizers ( Models 100S, 50, 200) Compatible Medical Device Reference List for US Customers, Document Numbers 15-53229 & 15-53230; STERRAD NX Sterilizers Compatible Medical Device Reference List for NX CustomerOutdated Compatibility Lists: Recalling firm has decided to discontinue dissemination of Compatible Medical Device Reference Lists and instrument assessment activitiesaccessdata.fda.gov
September 16, 200533513Not yet classifiedTerminatedVaporizer Plate Vaporizer Plate Consumable accessory used with the STERRAD 100 and the STERRAD 100SThe STERRAD 100 and the STERRAD 100S vaporizer plates are prone to displacement allowing micro-droplets of H2O2 to contact the load. If the vaporizer plate is dislodged, there is an increased chance for operators to have contact with H2O2 resulting in transient burns during the removal of the load.accessdata.fda.gov
March 16, 200531495Not yet classifiedTerminatedCidexplus Solution Test StripsCIDEX test strips were found to pass solution below MEC.accessdata.fda.gov
April 12, 200429903Not yet classifiedTerminatedCIDEX OPA Solution, ortho-Phthalaldehyde SolutionAnaphylactic-like reactions were reported following repeated cystoscopy for bladder cancer patients where the scope had been reprocessed in CIDEX OPA Solution.accessdata.fda.gov
December 17, 200328031Not yet classifiedTerminatedCidex Plus Test StripsMay not accurately detect minimum effective concentration (MEC)accessdata.fda.gov
September 4, 200327676Not yet classifiedTerminatedGluteraldehyde Concentration Indicators ''Browne GA Indicator for CIDEX PLUS Products''Performance failure complaints.accessdata.fda.gov
February 14, 200325725Not yet classifiedTerminatedCidex Solution Test Strips Browne GA Indicators for Cidex Solution Test Strips.Test strips which are used for QC of sterilant solution fail prematurely due to ingress of moisture.accessdata.fda.gov

Compare with other makers

Updated January 29, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.