Data / Medical devices / United States / Ad-Tech Medical Instrument Corp.
Ad-Tech Medical Instrument Corp.: FDA-registered device maker in Oak Creek, WI, United States, 11 510(k) clearances
Ad-Tech Medical Instrument Corp. is registered with the FDA (registration 2183456) in Oak Creek, WI, United States. It lists 17 device types. The FDA files 11 510(k) clearances under its listings, the newest dated May 18, 2023. 11 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 2183456
- Address
- 400 West Oakview Parkway, Oak Creek, WI, United States, 53154
- Owner or operator
- AD-TECH MEDICAL INSTRUMENT CORP. (2183456)
- Roles
- Manufacturer
- First device listed
- April 25, 2001
- Registered through
- 2026
- Brand names listed
- AD-BAND Post-Op Headwrap, Ad-Tech Brain Biopsy Needles, Ad-Tech Cannulas, Ad-Tech Depth Electrodes, Ad-Tech Measuring Rulers, Ad-Tech Obturators, Ad-Tech Passing Needles, Ad-Tech Pin Crimper and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 18, 2023 | K223276 | Anchor Bolts as Accessories to Depth Electrodes | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| May 18, 2023 | K223269 | Spencer Probe Depth Electrodes | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| January 25, 2020 | K191186 | Subdural Strip/Intraoperative Split Electrode, Subdural Grid/Intraoperative Grid Electrode, Dual-Sided Interhemispheric Subdural Electrode, Multi-Strip and Slit Grid Subdural Electrode, Intraoperative Mapping Grid Subdural Electrode | GYC | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| September 7, 2017 | K170442 | Cranial Drill Bits and Accessories | HBE | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| April 12, 2017 | K163355 | Depth Electrodes, Foramen Ovale Depth Eletrodes, Marco-Micro Depth Electrodes, Spencer Probe Depth Electrodes | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| May 6, 2016 | K152769 | FREMAP ELECTRODE | ETN | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| March 4, 2016 | K152547 | DNAP Electrode | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corporation | accessdata.fda.gov |
| April 24, 2012 | K112094 | BRAIN BIOPSY NEEDLE | HAW | Substantially Equivalent | Ad-Tech Medical Instrument Corp | accessdata.fda.gov |
| June 10, 1998 | K973454 | AD-TECH'S SPINAL ELECTRODE | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corp | accessdata.fda.gov |
| January 20, 1995 | K944061 | CUEVA CRANIAL NERVE ELECTRODE | GZL | Substantially Equivalent | Ad-Tech Medical Instrument Corp | accessdata.fda.gov |
| November 23, 1992 | K924348 | AD-TECH'S BRAIN BIOPSY NEEDLE FOR STEREOTAXIC | HAW | Substantially Equivalent | Ad-Tech Medical Instrument Corp | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| September 19, 2024 | 95414 | Class II | Completed | AD-TECH Spencer Probe Depth Electrode, REF SD04R-AP58X-000 4-Contact 1.12mm (A style) Depth Electrode | Ad-Tech is recalling these A-Style SD Depth Electrodes because a label discrepancy was identified on A style contact SD electrodes where the MR Conditional symbol was incorrectly placed instead of the MR Unsafe symbol. The A style contacts were not cleared for MR Conditional use. Our records indicate you have received one or more of the affected lots listed | accessdata.fda.gov |
| August 9, 2021 | 88590 | Class II | Terminated | Ad-Tech Lightweight CABRIO Cable - Product Usage: Designed for the purpose of connecting these electrodes to third party monitors/stimulators. | Incorrect version of labels were used. | accessdata.fda.gov |
| August 27, 2019 | 83628 | Class II | Terminated | AD-TECH Drill Sleeve Guides, used with Ad-Tech Placement Kits: (a) REF DSG-90-2.3N (b) REF DSG-6.3-090-2.4N | The inner diameter of the drill sleeve guide raw material was found to be under tolerance, potentially resulting in the drill bit seizing in the guide during surgery. | accessdata.fda.gov |
| June 18, 2019 | 83246 | Class II | Terminated | LSB Style Anchor Bolt. Labeled with the following parts: 13mm anodized anchor bolt body with anchor bolt cap containing a blue gasket and silicone cap, 21mm anodized anchor bolt body with anchor bolt cap containing a blu | On June 12, 2019 Ad-Tech was made aware that on three different occasions between March 1, 2019 and May 31, 2019 Ad-Tech personnel have distributed non-sterile anchor bolt parts to one independent representative and one international distributor, who may have subsequently sterilized the non-sterile anchor bolts for clinical use. Ad-Tech does not have regulat | accessdata.fda.gov |
| June 18, 2019 | 83179 | Class II | Terminated | Dual-Sided Interhemispheric, Grid, Intraoperative, Strip, Wyler Subdural Electrodes | Supplemental information provided with devices indicates that the subdural electrodes, depth electrodes, and anchor bolts are approved for use in the MR environment, for which they are not approved for such use. | accessdata.fda.gov |
| April 16, 2019 | 82719 | Class II | Terminated | AD-TECH Spencer Probe Depth Electrode Product Usage: The Ad-Tech Depth Electrodes (Depth Electrodes, Foramen Ovale Depth Electrodes, Macro Micro Depth Electrodes, Spencer Probe Depth Electrodes, Wyler Sphenoidal Depth El | An Ad-Tech Clinical Specialist, attended a case on April 15, 2019. During the case the surgeon encountered an issue after implanting four Ad-Tech depth electrodes. Upon initial device testing subsequent to implantation it was identified that two of the devices that were labeled as 8 contact depth electrodes (SD08R-SP05X-000) were in fact 6 contact depth elec | accessdata.fda.gov |
| May 2, 2018 | 80280 | Class II | Terminated | AD-TECH Medical Instrument Corporation Drill Sleeve Guides DSG-6-3-090-2.4N utilizing raw material (RM0677) from the following lots from vendor 00-0001062., AD0021502, AD0021628. Product Usage: The drill sleeve guides ar | The diameter of the drill sleeve guide raw material was found to be under tolerance, potentially resulting in the drill bit seizing in the guide during surgery. | accessdata.fda.gov |
| December 20, 2017 | 80002 | Class II | Terminated | Disposable Drill Kit which includes two drill bits, two drill stops, and two adjustment wrenches, sterile. The drill bits are 30cm long and made of stainless steel. The drill kits are supplied in a sterile state and are | There is a possibility that DDK2-2.4-30X Disposable Drill Kits, Lot Number 111664 208140649 contained 2.8mm drill bits from DDK2-2.8-30X Disposable Drill Kits, Lot Number 111745 208140649 and vice versa. | accessdata.fda.gov |
| March 29, 2016 | 73685 | Class II | Terminated | Ad-Tech Electrode Connection System/Cables. Lightweight TECH-ATTACH Cable Models: 1. L-DCL-4DINX (4 contacts: 1 terminal block with 4 connectors each); 2. L-DCL-6DINX (6 contacts: 1 terminal block with 6 connectors each) | Ad-Tech is recalling unopened/unused sterile cables intended to be used only with all compatible Ad-Tech electrodes for the purpose of connecting these electrodes to third party monitors/stimulators. This recall has been initiated due to package failures (i.e. compromised sterile barriers) that were identified during the execution of a shipping simulation in | accessdata.fda.gov |
| October 8, 2014 | 69436 | Class II | Terminated | Box Label: 3 mm Cueva Electrode Kit, Sterile EO, Rx Only, REF. CNE1-3KDINX. Pouch labels: Each kit contains 3 pouches. 3 mm Cueva Electrode CNE-3X, Cueva Electrode Applicator Wand CNE-100X, Cueva Electrode Leadwire CNE-L | The recall has been initiated due to concerns that the applicator wand may malfunction potentially causing the inability to monitor the VII cranial nerve.. | accessdata.fda.gov |
| December 18, 2012 | 64136 | Class I | Terminated | Ad-Tech Medical Instrument Corporation Macro Micro Subdural Electrode. For temporary (<30 days) use with recording, monitoring and stimulation equipment, for the recording, monitoring and stimulation of electrical signal | The microelectrodes are not flush with the silastic substrate, may contain sharp edges capable of abrading the cortical surface, and may have remaining pieces which may fracture and remain in the cortical tissue with the electrode is explanted. Recall expanded on 5/2/2013 to include additional Macro Micro Subdural Electrodes. | accessdata.fda.gov |
Compare with other makers
- All makers of Drills, Burrs, Trephines & Accessories (Simple, Powered)
- All makers of Drills, Burrs, Trephines & Accessories (Manual)
- All makers of Electrode, Depth
- All makers of Stimulator, Electrical, Evoked Response
- All makers of Device, Nerve Conduction Velocity Measurement
- All makers of Crimper, Pin
Updated October 24, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.