Data / Medical devices / Ireland / Abbott Vascular
Abbott Vascular: FDA-registered device maker in CLONMEL Tipperary, Ireland, 3 510(k) clearances and 5 PMA approvals
Abbott Vascular is registered with the FDA (registration 3005718570) in CLONMEL Tipperary, Ireland. It lists 8 device types. The FDA files 3 510(k) clearances and 5 PMA approvals under its listings, the newest dated February 13, 2026. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3005718570
- Address
- Cashel Road, CLONMEL Tipperary, Ireland, ,
- Owner or operator
- ABBOTT LABORATORIES (1415939)
- Roles
- Exporter to the US, Manufacturer
- First device listed
- May 5, 2006
- Registered through
- 2026
- Brand names listed
- Armada 14 NC PTA Catheter, Armada 14 PTA Catheter, Armada 18 PTA Catheter, Graftmaster, Graftmaster RX, MULTI-LINK 8 Stent System, Multi-Link 8-, Multi-Link Mini Vision and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Catheter, Angioplasty, Peripheral, Transluminal | LIT | 2 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Catheter, Flow Directed | DYG | 2 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Catheter, Percutaneous | DQY | 2 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Coronary Covered Stent | NIV | f | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Coronary Drug-Eluting Stent | NIQ | 3 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Device, Hemostasis, Vascular | MGB | 3 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Stent, Coronary | MAF | 3 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Stent, Iliac | NIO | 3 | Exporter to the US, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| February 13, 2026 | K252512 | Armada 14 NC PTA Catheter | LIT | Substantially Equivalent | ABBOTT MEDICAL | accessdata.fda.gov |
| July 6, 2015 | K151317 | Armada 18 PTA Catheter | LIT | Substantially Equivalent | Abbott Vascular | accessdata.fda.gov |
| December 7, 2010 | K102705 | ARMADA 14 PTA CATHETER | LIT | Substantially Equivalent | Abbott Vascular, Inc. | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| July 31, 2012 | P110043 | OMNILINK ELITE PERIPHERAL BALLOON-EXPANDABLE STENT SYSTEM | NIO | 14 | January 12, 2026 | accessdata.fda.gov |
| November 1, 2011 | P110019 | Xience Skypoint Everolimus Eluting Coronary Stent System | NIQ | 134 | October 1, 2026 | accessdata.fda.gov |
| December 21, 2005 | P050007 | STARCLOSE VASCULAR CLOSURE SYSTEM | MGB | 49 | April 17, 2026 | accessdata.fda.gov |
| July 16, 2003 | P020047 | MULTI-LINK VISION/MINI/8 CORONARY STENT SYSTEMS | MAF | 74 | June 14, 2023 | accessdata.fda.gov |
| April 30, 1997 | P960043 | PROSTAR 9 FR. PERCUTANEOUS VASCULAR SURGICAL (PVS) SYSTEM | MGB | 131 | September 24, 2026 | accessdata.fda.gov |
Compare with other makers
- All makers of Catheter, Angioplasty, Peripheral, Transluminal
- All makers of Stent, Iliac
- All makers of Catheter, Flow Directed
- All makers of Stent, Coronary
- All makers of Coronary Covered Stent
- All makers of Catheter, Percutaneous
Updated February 13, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.