Data / Medical devices / Urethrotome
Urethrotome (EZO): 20 FDA-registered makers in 4 countries
20 establishments in 4 countries are registered with the FDA to make Urethrotome (product code EZO, Class 2, 21 CFR 876.4770). 3 of them have a 510(k) clearance or PMA approval on file and 0 have a recall event. The FDA has issued 5 510(k) clearances under this code, the latest on May 12, 2000, and lists 1 recall event (0 Class I). FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- Product code
- EZO
- Device class
- 2
- Regulation
- 876.4770
- Medical specialty
- Gastroenterology, Urology
Makers by country
| Country | Makers |
|---|---|
| Germany | 14 |
| United States | 4 |
| Pakistan | 1 |
| India | 1 |
Makers of Urethrotome
Registered establishments that manufacture, contract manufacture, remanufacture, reprocess or own the specification of this device, with the 510(k) clearances, PMA approvals and recalls the FDA files under each. Best documented first.
| Maker | Location | Role | 510(k) clearances | Latest clearance | PMA approvals | Recall events | Class I | Source |
|---|---|---|---|---|---|---|---|---|
| Karl Storz Se & Co KG | TUTTLINGEN Baden-Wurttemberg, Germany | Specification developer | 2 | February 13, 1995 | 0 | 0 | 0 | api.fda.gov |
| Olympus Winter & Ibe GMBH | Hamburg, Germany | Complaint file establishment, Exporter to the US, Manufacturer, Specification developer | 1 | January 7, 1992 | 0 | 0 | 0 | api.fda.gov |
| Richard Wolf GMBH | KNITTLINGEN Baden-Wurttemberg, Germany | Manufacturer | 1 | May 12, 2000 | 0 | 0 | 0 | api.fda.gov |
| Acheron Instruments (pvt.) Ltd. | LAHORE Punjab, Pakistan | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Ackermann Instrumente GMBH | RIETHEIM, WEILHEIM Baden-Wurttemberg, Germany | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Endonest Medical Systems LLP | PALGHAR Maharashtra, India | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Gimmi GMBH | TUTTLINGEN Baden-Wurttemberg, Germany | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Henke-Sass Wolf, GMBH. | TUTTLINGEN Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Josef Bacher GMBH | Rietheim-Weilheim Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Karl Storz Se & Co. KG | TUTTLINGEN Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Karl Storz Se & Co. KG | TUTTLINGEN Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Karl Storz Se & Co. KG | NEUHAUSEN OBECK Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Medicon, E.G. | TUTTLINGEN Baden-Wurttemberg, Germany | Contract manufacturer, Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| National Advanced Endoscopy Devices, Inc. | Canoga Park, CA, United States | Manufacturer, Repackager or relabeler | 0 | 0 | 0 | 0 | api.fda.gov | |
| Primo Medical Group, Inc | W Bridgewater, MA, United States | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| RZ Medizintechnik GMBH | TUTTLINGEN Baden-Wurttemberg, Germany | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| STERIS Corporation | Saint Louis, MO, United States | Specification developer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Tekno Medical Optik-Chirurgie GMBH | TUTTLINGEN-Nendingen Baden-Wurttemberg, Germany | Manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Teufel & Gerlach GmbH | Tuttlingen Baden-Wurttemberg, Germany | Contract manufacturer | 0 | 0 | 0 | 0 | api.fda.gov | |
| Uramix, Inc. | E Lansdowne, PA, United States | Specification developer | 0 | 0 | 0 | 0 | api.fda.gov |
Updated May 12, 2000. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.